Fundamentals of Trapped Ion Mobility Spectrometry
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Trapped ion mobility spectrometry (TIMS) is a relatively new gas-phase separation method that has been coupled to quadrupole orthogonal acceleration time-of-flight mass spectrometry. The TIMS analyzer is a segmented rf ion guide wherein ions are mobility-analyzed using an electric field that holds ions stationary against a moving gas, unlike conventional drift tube ion mobility spectrometry where the gas is stationary. Ions are initially trapped, and subsequently eluted from the TIMS analyzer over time according to their mobility (K). Though TIMS has achieved a high level of performance (R > 250) in a small device (<5 cm) using modest operating potentials (<300 V), a proper theory has yet to be produced. Here, we develop a quantitative theory for TIMS via mathematical derivation and simulations. A one-dimensional analytical model, used to predict the transit time and theoretical resolving power, is described. Theoretical trends are in agreement with experimental measurements performed as a function of K, pressure, and the axial electric field scan rate. The linear dependence of the transit time with 1/K provides a fundamental basis for determination of reduced mobility or collision cross section values by calibration. The quantitative description of TIMS provides an operational understanding of the analyzer, outlines the current performance capabilities, and provides insight into future avenues for improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transport Properties of Ions in Gases
Mason, E. A., & McDaniel, E. W. (1988) · Wiley eBooks · doi:10.1002/3527602852 · Cited by 1,797
Bernstein, S. L., Dupuis, N. F., Lazo, N. D., Wyttenbach, T., Condron, M. M., Bitan, G., Teplow, D. B., Shea, J.-E., Ruotolo, B. T., Robinson, C. V., et al. (2009) · Nature Chemistry · doi:10.1038/nchem.247 · Cited by 918
Bush, M. F., Hall, Z., Giles, K., Hoyes, J., Robinson, C. V., & Ruotolo, B. T. (2010) · Analytical Chemistry · doi:10.1021/ac1022953 · Cited by 796
Theory of plasma chromatography/gaseous electrophoresis. Review
Revercomb, H. E., & Mason, E. A. (1975) · Analytical Chemistry · doi:10.1021/ac60357a043 · Cited by 755
Applications of a travelling wave‐based radio‐frequency‐only stacked ring ion guide
Giles, K., Pringle, S. D., Worthington, K. R., Little, D., Wildgoose, J. L., & Bateman, R. H. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1641 · Cited by 727
Inhomogeneous RF Fields: A Versatile Tool for the Study of Processes with Slow Ions
Gerlich, D. (1992) · Advances in Chemical Physics · doi:10.1002/9780470141397.ch1 · Cited by 685
Evidence for Macromolecular Protein Rings in the Absence of Bulk Water
Ruotolo, B. T., Giles, K., Campuzano, I., Sandercock, A. M., Bateman, R. H., & Robinson, C. V. (2005) · Science · doi:10.1126/science.1120177 · Cited by 596
Naked Protein Conformations: Cytochrome c in the Gas Phase
Clemmer, D. E., Hudgins, R. R., & Jarrold, M. F. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00145a037 · Cited by 491
von Helden, G., Gotts, N. G., & Bowers, M. T. (1993) · Nature · doi:10.1038/363060a0 · Cited by 423
May, J. C., Goodwin, C. R., Lareau, N. M., Leaptrot, K. L., Morris, C. B., Kurulugama, R. T., Mordehai, A., Klein, C., Barry, W., Darland, E., et al. (2014) · Analytical Chemistry · doi:10.1021/ac4038448 · Cited by 401
Bleiholder, C., Dupuis, N. F., Wyttenbach, T., & Bowers, M. T. (2011) · Nature Chemistry · doi:10.1038/nchem.945 · Cited by 366
von Helden, G., Wyttenbach, T., & Bowers, M. T. (1995) · Science · doi:10.1126/science.267.5203.1483 · Cited by 363
Effect of the long-range potential on ion mobility measurements
Wyttenbach, T., von Helden, G., Batka, J. J., Carlat, D., & Bowers, M. T. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00236-x · Cited by 332
Gas-phase separation using a trapped ion mobility spectrometer
Fernandez-Lima, F., Kaplan, D. A., Suetering, J., & Park, M. A. (2011) · International Journal for Ion Mobility Spectrometry · doi:10.1007/s12127-011-0067-8 · Cited by 315
Self-citationThe ion funnel: Theory, implementations, and applications
Kelly, R. T., Tolmachev, A. V., Page, J. S., Tang, K., & Smith, R. D. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20232 · Cited by 280
Koeniger, S. L., Merenbloom, S. I., Valentine, S. J., Jarrold, M. F., Udseth, H. R., Smith, R. D., & Clemmer, D. E. (2006) · Analytical Chemistry · doi:10.1021/ac051060w · Cited by 272
Hall, Z., Politis, A., Bush, M. F., Smith, L. J., & Robinson, C. V. (2012) · Journal of the American Chemical Society · doi:10.1021/ja2096859 · Cited by 267 · cited 1×
“5 to 10 Torr) drift tube IMS with mass spectrometry (MS) has proven to be valuable for a number of chemical [6–10], physical [11–15], and biological [16–31] applications.”
Interrogating viral capsid assembly with ion mobility–mass spectrometry
Uetrecht, C., Barbu, I. M., Shoemaker, G. K., van Duijn, E., & Heck, A. J. R. (2011) · Nature Chemistry · doi:10.1038/nchem.947 · Cited by 267
Ion dynamics in a trapped ion mobility spectrometer
Hernandez, D. R., DeBord, J. D., Ridgeway, M. E., Kaplan, D. A., Park, M. A., & Fernandez-Lima, F. (2014) · The Analyst · doi:10.1039/c3an02174b · Cited by 267
Self-citationShaffer, S. A., Prior, D. C., Anderson, G. A., Udseth, H. R., & Smith, R. D. (1998) · Analytical Chemistry · doi:10.1021/ac9802170 · Cited by 262
Schaffer, S. A., Tang, K., Anderson, G. A., Prior, D. C., Udseth, H. R., & Smith, R. D. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19971030)11:16<1813::aid-rcm87>3.0.co;2-d · Cited by 262
Note: Integration of trapped ion mobility spectrometry with mass spectrometry
Fernandez-Lima, F. A., Kaplan, D. A., & Park, M. A. (2011) · Review of Scientific Instruments · doi:10.1063/1.3665933 · Cited by 235
Self-citationHigh Resolution Trapped Ion Mobility Spectrometery of Peptides
Silveira, J. A., Ridgeway, M. E., & Park, M. A. (2014) · Analytical Chemistry · doi:10.1021/ac501261h · Cited by 196
Self-citationA new, higher resolution, ion mobility mass spectrometer
Kemper, P. R., Dupuis, N. F., & Bowers, M. T. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.01.012 · Cited by 195
Trimpin, S., & Clemmer, D. E. (2008) · Analytical Chemistry · doi:10.1021/ac801573n · Cited by 175
Silveira, J. A., Fort, K. L., Kim, D., Servage, K. A., Pierson, N. A., Clemmer, D. E., & Russell, D. H. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4114193 · Cited by 163
Self-citationNumber of Solution States of Bradykinin from Ion Mobility and Mass Spectrometry Measurements
Pierson, N. A., Chen, L., Valentine, S. J., Russell, D. H., & Clemmer, D. E. (2011) · Journal of the American Chemical Society · doi:10.1021/ja203895j · Cited by 153
Baker, E. S., Clowers, B. H., Li, F., Tang, K., Tolmachev, A. V., Prior, D. C., Belov, M. E., & Smith, R. D. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.03.031 · Cited by 143
Brocker, E. R., ANDERSON, S. E. J., Northrop, B. H., Stang, P. J., & Bowers, M. T. (2010) · Journal of the American Chemical Society · doi:10.1021/ja105702y · Cited by 143
Resolution measurement for ion mobility spectrometry
Rokushika, S., Hatano, H., Baim, M. A., & Hill, H. H. (1985) · Analytical Chemistry · doi:10.1021/ac00286a023 · Cited by 137
Allen, S., Schwartz, A. M., & Bush, M. F. (2013) · Analytical Chemistry · doi:10.1021/ac403139d · Cited by 98
Bleiholder, C., Do, T., Wu, C., Economou, N. J., Bernstein, S. S., Buratto, S., Shea, J., & Bowers, M. (2013) · Journal of the American Chemical Society · doi:10.1021/ja406197f · Cited by 88
Politis, A., Park, A. Y., Hall, Z., Ruotolo, B. T., & Robinson, C. V. (2013) · Journal of Molecular Biology · doi:10.1016/j.jmb.2013.04.006 · Cited by 77
May, J. C., & Russell, D. H. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0148-2 · Cited by 74
Zeleny, J. (1898) · The London Edinburgh and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786449808621173 · Cited by 74
Gas-phase conformations of cationized poly(styrene) oligomers
Gidden, J. A., Bowers, M. T., Jackson, A. T., & Scrivens, J. H. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00367-7 · Cited by 73
Isomerization Kinetics of AT Hook Decapeptide Solution Structures
Schenk, E. R., Ridgeway, M. E., Park, M. A., Leng, F., & Fernandez-Lima, F. A. (2013) · Analytical Chemistry · doi:10.1021/ac403386q · Cited by 59
Self-citationSilveira, J. A., Servage, K. A., Gamage, C. M., & Russell, D. H. (2013) · The Journal of Physical Chemistry A · doi:10.1021/jp311278a · Cited by 53
Self-citationSchenk, E. R., Mendez, V., Landrum, J. T., Ridgeway, M. E., Park, M. A., & Fernandez-Lima, F. A. (2014) · Analytical Chemistry · doi:10.1021/ac403153m · Cited by 48
Self-citationBiomolecular Signatures of Diabetic Wound Healing by Structural Mass Spectrometry
Hines, K. M., Ashfaq, S., Davidson, J. M., Opalenik, S. R., Wikswo, J. P., & MCLEAN, J. A. J. (2013) · Analytical Chemistry · doi:10.1021/ac303594m · Cited by 18
Fort, K. L., Silveira, J. A., & Russell, D. H. (2013) · Analytical Chemistry · doi:10.1021/ac401629b · Cited by 18
Self-citation
Cited by
Meier, F., Brunner, A.-D., Koch, S., Koch, H., Lubeck, M., Krause, M., Goedecke, N., Decker, J., Kosinski, T., Park, M. A., et al. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.000900 · Cited by 965
Self-citationIon Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead
Dodds, J. N., & Baker, E. S. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02288-2 · Cited by 574
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
“Mathematically, the electric field strength at axial location z in the analyzer at time t is given by (Michelmann et al., 2015; Bleiholder, 2016):”
InfluentialSelf-citationIon Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
Meier, F., Beck, S., Grassl, N., Lubeck, M., Park, M. A., Raether, O., & Mann, M. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00932 · Cited by 423
Self-citation
Metadata
- Authors
- Michelmann, K., Silveira, J. A., Ridgeway, M. E., & Park, M. A.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-10-21
- Volume
- 26
- Issue
- 1
- Pages
- 14-24
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2088546850
- Cited by
- 374
- References
- 41
- FWCI
- 7.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.