Fundamentals of Trapped Ion Mobility Spectrometry
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Trapped ion mobility spectrometry (TIMS) is a relatively new gas-phase separation method that has been coupled to quadrupole orthogonal acceleration time-of-flight mass spectrometry. The TIMS analyzer is a segmented rf ion guide wherein ions are mobility-analyzed using an electric field that holds ions stationary against a moving gas, unlike conventional drift tube ion mobility spectrometry where the gas is stationary. Ions are initially trapped, and subsequently eluted from the TIMS analyzer over time according to their mobility (K). Though TIMS has achieved a high level of performance (R > 250) in a small device (<5 cm) using modest operating potentials (<300 V), a proper theory has yet to be produced. Here, we develop a quantitative theory for TIMS via mathematical derivation and simulations. A one-dimensional analytical model, used to predict the transit time and theoretical resolving power, is described. Theoretical trends are in agreement with experimental measurements performed as a function of K, pressure, and the axial electric field scan rate. The linear dependence of the transit time with 1/K provides a fundamental basis for determination of reduced mobility or collision cross section values by calibration. The quantitative description of TIMS provides an operational understanding of the analyzer, outlines the current performance capabilities, and provides insight into future avenues for improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transport Properties of Ions in Gases
Mason, E. A., & McDaniel, E. W. (1988) · Wiley eBooks · doi:10.1002/3527602852 · Cited by 1,797
Bernstein, S. L., Dupuis, N. F., Lazo, N. D., Wyttenbach, T., Condron, M. M., Bitan, G., Teplow, D. B., Shea, J.-E., Ruotolo, B. T., Robinson, C. V., et al. (2009) · Nature Chemistry · doi:10.1038/nchem.247 · Cited by 918
Bush, M. F., Hall, Z., Giles, K., Hoyes, J., Robinson, C. V., & Ruotolo, B. T. (2010) · Analytical Chemistry · doi:10.1021/ac1022953 · Cited by 796
Theory of plasma chromatography/gaseous electrophoresis. Review
Revercomb, H. E., & Mason, E. A. (1975) · Analytical Chemistry · doi:10.1021/ac60357a043 · Cited by 755
Applications of a travelling wave‐based radio‐frequency‐only stacked ring ion guide
Giles, K., Pringle, S. D., Worthington, K. R., Little, D., Wildgoose, J. L., & Bateman, R. H. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1641 · Cited by 727
Inhomogeneous RF Fields: A Versatile Tool for the Study of Processes with Slow Ions
Gerlich, D. (1992) · Advances in Chemical Physics · doi:10.1002/9780470141397.ch1 · Cited by 685
Evidence for Macromolecular Protein Rings in the Absence of Bulk Water
Ruotolo, B. T., Giles, K., Campuzano, I., Sandercock, A. M., Bateman, R. H., & Robinson, C. V. (2005) · Science · doi:10.1126/science.1120177 · Cited by 596
Naked Protein Conformations: Cytochrome c in the Gas Phase
Clemmer, D. E., Hudgins, R. R., & Jarrold, M. F. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00145a037 · Cited by 491
von Helden, G., Gotts, N. G., & Bowers, M. T. (1993) · Nature · doi:10.1038/363060a0 · Cited by 423
May, J. C., Goodwin, C. R., Lareau, N. M., Leaptrot, K. L., Morris, C. B., Kurulugama, R. T., Mordehai, A., Klein, C., Barry, W., Darland, E., et al. (2014) · Analytical Chemistry · doi:10.1021/ac4038448 · Cited by 401
Cited by
Meier, F., Brunner, A.-D., Koch, S., Koch, H., Lubeck, M., Krause, M., Goedecke, N., Decker, J., Kosinski, T., Park, M. A., et al. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.000900 · Cited by 965
Self-citationIon Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead
Dodds, J. N., & Baker, E. S. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02288-2 · Cited by 574
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
“Mathematically, the electric field strength at axial location z in the analyzer at time t is given by (Michelmann et al., 2015; Bleiholder, 2016):”
InfluentialSelf-citationIon Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
Meier, F., Beck, S., Grassl, N., Lubeck, M., Park, M. A., Raether, O., & Mann, M. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00932 · Cited by 423
Self-citationRecent advances in mass spectrometry based clinical proteomics: applications to cancer research
Macklin, A., Khan, S., & Kislinger, T. (2020) · Clinical Proteomics · doi:10.1186/s12014-020-09283-w · Cited by 317
Trapped ion mobility spectrometry: A short review
Ridgeway, M. E., Lubeck, M., Jordens, J., Mann, M., & Park, M. A. (2018) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2018.01.006 · Cited by 308
Self-citationMetabolomics and lipidomics using traveling-wave ion mobility mass spectrometry
Paglia, G., & Astarita, G. (2017) · Nature Protocols · doi:10.1038/nprot.2017.013 · Cited by 248
Spraggins, J. M., Djambazova, K. V., Rivera, E. S., Migas, L. G., Neumann, E. K., Fuetterer, A., Suetering, J., Goedecke, N., Ly, A., Van de Plas, R., et al. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03612 · Cited by 237
Christofi, E., & Barran, P. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00600 · Cited by 233
Mass spectrometry-based proteomics as an emerging tool in clinical laboratories
Birhanu, A. G. (2023) · Clinical Proteomics · doi:10.1186/s12014-023-09424-x · Cited by 220
“…of gas phase peptide ions, as in high-field asymmetric ion mobility spectrometry (FAIMS) and trapped ion mobility spectrometry (TIMS), have been shown to reduce MS1 complexity and MS2 contamination from co-eluted and co-isolated peptides [66, 67], thereby increasing peptide detection by 30% [68].”
BackgroundTrapped ion mobility spectrometry and PASEF enable in-depth lipidomics from minimal sample amounts
Vasilopoulou, C. G., Sulek, K., Brunner, A.-D., Meitei, N. S., Schweiger-Hufnagel, U., Meyer, S. W., Barsch, A., Mann, M., & Meier, F. (2020) · Nature Communications · doi:10.1038/s41467-019-14044-x · Cited by 218
Ion Mobility Spectrometry in Food Analysis: Principles, Current Applications and Future Trends
Hernández-Mesa, M., Ropartz, D., García-Campaña, A. M., Rogniaux, H., Dervilly-Pinel, G., & Le Bizec, B. (2019) · Molecules · doi:10.3390/molecules24152706 · Cited by 202
“More detailed information about the operation and physical principles of the different IMS forms can be found in specialized literature [17,19,25,27,28].”
BackgroundZheng, X., Aly, N. A., Zhou, Y., Dupuis, K. T., Bilbao, A., Paurus, V. L., Orton, D. J., Wilson, R., Payne, S. H., Smith, R. D., et al. (2017) · Chem. Sci. · doi:10.1039/c7sc03464d · Cited by 200
Mass Spectrometry-Based Techniques to Elucidate the Sugar Code
Grabarics, M., Lettow, M., Kirschbaum, C., Greis, K., Manz, C., & Pagel, K. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00380 · Cited by 198
Adding a new separation dimension to MS and LC–MS: What is the utility of ion mobility spectrometry?
D'Atri, V., Causon, T., Hernandez‐Alba, O., Mutabazi, A., Veuthey, J., Cianferani, S., & Guillarme, D. (2018) · Journal of Separation Science · doi:10.1002/jssc.201700919 · Cited by 184
Trapped Ion Mobility Spectrometry and Parallel Accumulation–Serial Fragmentation in Proteomics
Meier, F., Park, M. A., & Mann, M. (2021) · Molecular & Cellular Proteomics · doi:10.1016/j.mcpro.2021.100138 · Cited by 183
“In practice, however, a linear model is commonly used to calibrate TIMS elution voltages with known 1/K0 values (40, 46, 94).”
BackgroundMethodSelf-citationIon Mobility Collision Cross Section Compendium
May, J. C., Morris, C. B., & McLean, J. A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04905 · Cited by 183
Dodds, J. N., May, J. C., & McLean, J. A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02827 · Cited by 182
Glycan Analysis by Ion Mobility–Mass Spectrometry
Hofmann, J., & Pagel, K. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201701309 · Cited by 180
Paglia, G., Smith, A. J., & Astarita, G. (2022) · Mass Spectrometry Reviews · doi:10.1002/mas.21686 · Cited by 176
Recent technological developments for native mass spectrometry
Webb, I. K. (2022) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2021.140732 · Cited by 29
A high-throughput biocatalytic platform for screening isomeric kainoid natural products
Shepherd, R. A., Ramachandra, M., Hopiavuori, A. R., Jones, M. C., Fihn, C. A., Tabag, A. J., Manjunath, A., Gad, L. Y., Whipple, C. R., McKinnie, S. M. K., et al. (2026) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2025.103092 · Cited by 2
A High-Throughput Biocatalytic Platform for Screening Isomeric Kainoid Natural Products
Shepherd, R. A., Ramachandra, M., Hopiavuori, A. R., Jones, M. C., Fihn, C. A., Tabag, A. J., Manjunath, A., Gad, L. Y., Whipple, C. R., McKinnie, S. M. K., et al. (2025) · doi:10.1101/2025.09.07.674781 · Cited by 2
Metadata
- Authors
- Michelmann, K., Silveira, J. A., Ridgeway, M. E., & Park, M. A.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-10-21
- Volume
- 26
- Issue
- 1
- Pages
- 14-24
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2088546850
- Cited by
- 374
- References
- 41
- FWCI
- 7.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.