Assessment of structural, biological and drug release properties of electro-sprayed poly lactic acid-dexamethasone coating for biomedical applications
Open accessThe DOI matches its Crossref record; 82 of the 82 references it cites were found in a registry or an index.
Abstract
The efficacy of an implant is highly depends on its coating characteristics mainly determined by polymer properties and coating technique. Electro-spraying is an inexpensive and versatile coating technique with various advantages for biomedical application. In this study, the efficacy of electro-sprayed (ES) poly lactic acid (PLA)-dexamethasone (DEX) coatings for medical implants was evaluated and compared with spin-coated samples as control. Structural properties of coatings were investigated using X-ray diffraction (XRD) and differential scanning calorimetry (DSC). Confocal and scanning electron microscopy (SEM), contact angle measurement and nanoindentation tests were used to study surface properties. Coating degradation rate and drug release profile were studied for 40 days. Cell viability experiments were also performed on human endothelial (HUVEC) and smooth muscle cells (HUASMC) using MTT assay and SEM. XRD and DSC analysis showed electro-spraying significantly reduce PLA and DEX crystallinity. Surface studies showed ES coatings has significantly higher hydrophobicity and roughness with microbead-nanofiber morphology vs. micro-nanoporous structure of spin-coated samples. Initial burst release of DEX was 22% and 10% after 6 h and total release was 71% and 46% after 40 days for ES and spin-coated samples, respectively. HUVEC viability of ES samples was higher than spin-coated ones after 1 and 4 days. However, dexamethasone release profile reduced HUASMC proliferation in ES PLA-DEX samples in comparison to spin-coated after 1 and 3 days. In conclusion, in vitro results showed potential of ES PLA-DEX as a biocompatible and efficient anti-inflammatory coating with suitable drug release profile for future applications such as coronary drug eluting stents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915
Odian, G. (2004) · doi:10.1002/047147875x · Cited by 7,158
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Electrospinning: Applications in drug delivery and tissue engineering
Sill, T. J., & von Recum, H. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.011 · Cited by 3,289
Kamaly, N., Yameen, B., Wu, J., & Farokhzad, O. C. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00346 · Cited by 3,070
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617 · cited 2×
“Polymer degradation depends on factors such as MW, hydrophobicity and crystallinity [28].”
BackgroundEffects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion
Yeung, T., Georges, P. C., Flanagan, L. A., Marg, B., Ortiz, M., Funaki, M., Zahir, N., Ming, W., Weaver, V., & Janmey, P. A. (2005) · Cell Motility and the Cytoskeleton · doi:10.1002/cm.20041 · Cited by 2,325
Polymers for Drug Delivery Systems
Liechty, W. B., Kryscio, D. R., Slaughter, B. V., & Peppas, N. A. (2010) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-073009-100847 · Cited by 1,608
Substrate Elasticity Regulates Skeletal Muscle Stem Cell Self-Renewal in Culture
Gilbert, P. M., Havenstrite, K. L., Magnusson, K. E. G., Sacco, A., Leonardi, N. A., Kraft, P., Nguyen, N. K., Thrun, S., Lutolf, M. P., & Blau, H. M. (2010) · Science · doi:10.1126/science.1191035 · Cited by 1,587
Cell Biology of Extracellular Matrix
(1988) · Springer eBooks · doi:10.1007/978-1-4613-0881-2 · Cited by 1,470
Cited by
Dawud, H., & Ammar, A. A. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15020526 · Cited by 76
“The presence of numerous distinct peaks in the DEX diffractogram implies its crystalline nature, as reported in the literature [34,35].”
BackgroundLakalayeh, G. A., Rahvar, M., Nazeri, N., & Ghanbari, H. (2022) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2022.103878 · Cited by 25
Self-citationRahvar, M., Lakalayeh, G. A., Nazeri, N., Karimi, R., Borzouei, H., & Ghanbari, H. (2022) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2022.126445 · Cited by 17
Self-citationRahvar, M., Manoochehrabadi, T., Lakalayeh, G. A., Barzegar, Z., Karimi, R., & Ghanbari, H. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c17930 · Cited by 13
Self-citationBacterial nanocellulose as a simple and tailorable platform for controlled drug release
Costa, L., Carvalho, A. F., Fernandes, A. J. S., Campos, T., Dourado, N., Costa, F. M., & Gama, M. (2024) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2024.124560 · Cited by 12
Daryabari, S., Ghasemian, M., Lotfi, E., Solouki, A., Lin, K., Manoochehrabadi, T., Imeni, S. M. H., & Ghaleh, H. E. G. (2025) · Transplantation and Cellular Therapy · doi:10.1016/j.jtct.2025.09.024 · Cited by 12
Pardini, F. M., Faccia, P. A., Amalvy, J. I., González, A., & Irusta, L. (2023) · International Journal of Polymeric Materials · doi:10.1080/00914037.2023.2222332 · Cited by 6
“By optimizing the process variables (e.g., concentration of polymer, solution solvent type, applied voltage, or flow rate, among the most important) this technique can be effectively used for encapsulation of a wide range of materials [3] .”
MethodApplications of Electrospraying in Tissue Repair and Regeneration
Sable, R., Maity, P. P., & Kapat, K. (2024) · IntechOpen eBooks · doi:10.5772/intechopen.1005320 · Cited by 4
Functional Surface Modification of Magnesium Implant by Drug-Loaded Biodegradable Polymer Coating
Park, J.-E., Jang, Y.-S., Ko, S.-O., & Lee, M.-H. (2026) · Applied Sciences · doi:10.3390/app16031542 · Cited by 3
Polymeric coatings integrated with drug-loaded micro and nanostructures for bioimplant applications
Shahnavaz, A., Moghaddam, M. M., & Mohammadloo, H. E. (2026) · Biomedical Materials · doi:10.1088/1748-605x/ae4153 · Cited by 2
“Rahvar et al [109], for example, investigated the effectiveness of electro-sprayed PLA coatings embedded with DEX for potential use in implantable devices, with spin-coated coatings used as the control sample for comparison.”
InfluentialTavakol, S., Zahmatkeshan, M., & Rahvar, M. (2023) · ACS symposium series · doi:10.1021/bk-2023-1438.ch010 · Cited by 1
Self-citationMiranda, P., Tártara, L. I., Castro, A., Zimet, P., Faccio, R., Palma, S. D., Mombrú, Á. W., & Pardo, H. (2025) · Pharmaceutics · doi:10.3390/pharmaceutics17091191 · Cited by 2
“Moreover, in PLGA-based systems, hydrolytic chain scission progressively increases water uptake and porosity, facilitating drug release over time [12,21].”
Nanoimmunotherapy and nanomedicine
Rahvar, M., Gholami, L., & Rahmani, M. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-21521-6.00004-1
Self-citationRahvar, M., Manoochehrabadi, T., Marouf, B. T., Lakalayeh, G. A., Kakolvand, R., Habibi, H., & Ghanbari, H. (2026) · BioNanoScience · doi:10.1007/s12668-025-02310-w · Cited by 1
“The apparent hydrophobicity of the electrosprayed coatings could be influenced by the highly porous micro/nano - structure, which can trap air and increase contact angles [1, 22].”
InfluentialSelf-citationCellulose triacetate microparticles via electrospraying and their antibacterial applications
Kouali, C. E., kalaaoui, K. E., Boukhriss, A., Messoudi, M. E., Slassi, S., Hajji, L., Chaoui, M. A., & Gmouh, S. (2026) · Particuology · doi:10.1016/j.partic.2026.07.023
Metadata
- Authors
- Rahvar, M., Ahmadi Lakalayeh, G., Nazeri, N., Marouf, B. T., Shirzad, M., Najafi T. Shabankareh, A., & Ghanbari, H.
- Affiliations
- Iran University of Medical Sciences (IR)
- Qazvin University of Medical Sciences (IR)
- Urmia University (IR)
- University of Tehran (IR)
- Tehran Heart Center (IR)
- Corresponding author
- Ghanbari, Hossein
- Venue
- Biomedical Engineering Letters
- Published
- 2021-09-03
- Volume
- 11
- Issue
- 4
- Pages
- 393-406
- ISSN
- 2093-985X (ISSN-L)
- 2093-9868
- PMC
- PMC8486896
- OpenAlex
- W3198493024
- Semantic Scholar
- 5d5ad3b9f35e0c1794337c4f96d3d9666bc6b511
- Cited by
- 15
- References
- 82
- Citations by year
- 2026: 4 · 2025: 4 · 2024: 2 · 2023: 3 · 2022: 2
- FWCI
- 0.46
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Biomedical Engineering Letters (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Tehran University of Medical Sciences and Health Services (Grant number 93–03-87–27070))
- National Institute for Medical Research Development (Grant number 957310)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Physical Sciences › Engineering › Mechanical Engineering › Surface Treatment and Coatings
- Keywords
- electrospraying, polylactic acid, dexamethasone, drug-eluting coatings, biomedical implants, coating crystallinity, hydrophobicity, surface roughness, nanofiber morphology, drug release profile, coating degradation, endothelial cell viability, smooth muscle cell proliferation, anti-inflammatory coatings, spin coating comparison
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.