CoChat

WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance

Open access
Willits, Iain, Keltie, Kim, Craig, Joyce, Sims, Andrew · 2014 · Applied Health Economics and Health Policy
Cited by 67

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The Microlife(®) 'WatchBP Home A' oscillometric blood pressure monitor detects irregular pulse, suggestive of atrial fibrillation (AF). Early detection of AF can prevent thromboembolic stroke via anticoagulation therapy. The device was considered by the Medical Technologies Evaluation Programme of the UK National Institute for Health and Care Excellence (NICE). The sponsor (Microlife) identified 10 studies. These were reviewed by an External Assessment Centre (EAC) which considered three relevant to the decision problem, including one which found the device detected AF more accurately (sensitivity 96.8%, specificity 88.8%) than pulse palpation (87.2, 81.3%). The EAC concluded the technology had potential to improve detection of AF, but the three studies had uncertain external validity. From a cost-consequence model with a 1-year timeframe, the sponsor calculated the device would reduce electrocardiogram (ECG) referrals and prevent strokes, but incur anticoagulation therapy costs, with net NHS savings of £11.6 million and prevention of 221 strokes, annually. The EAC criticised the model for its limited time horizon, and its consideration of symptomatic AF patients who were outside the scope issued by NICE. The EAC applied a de novo Markov model, with a 10-year timeframe. The per use saving was calculated as £2.98 for asymptomatic patients aged 65-74 years and £4.26 for those aged 75-84 years, with the prevention of 53-117 nonfatal and 28-65 fatal strokes per 100,000 people screened. Following consideration by the NICE Medical Technologies Advisory Committee, NICE judged that the case for adoption was supported by the evidence (Medical Technologies Guidance 13; MTG13).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s40258-014-0096-7

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 67

Metadata

Authors
Willits, I., Keltie, K., Craig, J., & Sims, A.
Venue
Applied Health Economics and Health Policy
Published
2014-03-25
Volume
12
Issue
3
Pages
255-265
ISSN
  • 1175-5652 (ISSN-L)
  • 1179-1896
OpenAlex
W2000820525
Cited by
67
References
6
FWCI
5.90
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance. https://app.cochat.ai/papers/10.1007/s40258-014-0096-7
The paper
Willits, I., Keltie, K., Craig, J., & Sims, A. (2014). WatchBP Home A for Opportunistically Detecting Atrial Fibrillation During Diagnosis and Monitoring of Hypertension: A NICE Medical Technology Guidance. Applied Health Economics and Health Policy. https://doi.org/10.1007/s40258-014-0096-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.