Abstract

Objective: New electronic devices offer an opportunity within routine primary care settings for improving the detection of atrial fibrillation (AF), which is a common cardiac arrhythmia and a modifiable risk factor for stroke. We aimed to assess the performance of a modified blood pressure (BP) monitor and two single-lead ECG devices, as diagnostic triage tests for the detection of AF. Setting: 6 General Practices in the UK. Participants: 1000 ambulatory patients aged 75 years and over. Primary and secondary outcome measures: Comparative diagnostic accuracy of modified BP monitor and single-lead ECG devices, compared to reference standard of 12-lead ECG, independently interpreted by cardiologists. Results: A total of 79 participants (7.9%) had AF diagnosed by 12-lead ECG. All three devices had a high sensitivity (93.9–98.7%) and are useful for ruling out AF. WatchBP is a better triage test than Omron autoanalysis because it is more specific—89.7% (95% CI 87.5% to 91.6%) compared to 78.3% (95% CI 73.0% to 82.9%), respectively. This would translate into a lower follow-on ECG rate of 17% to rule in/rule out AF compared to 29.7% with the Omron text message in the study population. The overall specificity of single-lead ECGs analysed by a cardiologist was 94.6% for Omron and 90.1% for Merlin. Conclusions: WatchBP performs better as a triage test for identifying AF in primary care than the single-lead ECG monitors as it does not require expertise for interpretation and its diagnostic performance is comparable to single-lead ECG analysis by cardiologists. It could be used opportunistically to screen elderly patients for undiagnosed AF at regular intervals and/or during BP measurement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmjopen-2013-004565

Cites

27 of 28 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Patient recruitment flowchart.
Figure 1 Patient recruitment flowchart.CC BY-NC · PubMed Central
Figure 2 Predictive value of WatchBP and Omron autoanalysis for detecting atrial fibrillation (AF).
Figure 2 Predictive value of WatchBP and Omron autoanalysis for detecting atrial fibrillation (AF).CC BY-NC · PubMed Central
Figure 3 Forest plot of diagnostic accuracy per cardiologist of Omron and Merlin single-lead ECGs.
Figure 3 Forest plot of diagnostic accuracy per cardiologist of Omron and Merlin single-lead ECGs.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Research works printed but not linked: 1

  1. Macaskill P Gatsonis C Deeks J . Chapter 10: analysing and presenting results. In: Deeks JJ Bossuyt PM Gatsonis C , eds. Cochrane handbook for systematic reviews of diagnostic test accuracy version 1.0. The Cochrane Collaboration, 2010 :1–61.

Cited by

See all 119

Metadata

Authors
Kearley, K., Selwood, M., Van den Bruel, A., Thompson, M., Mant, D., Hobbs, F. R., Fitzmaurice, D., & Heneghan, C.
Affiliations
  • University of Oxford (GB)
  • Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
  • University of Washington (US)
  • University of Birmingham (GB)
Corresponding author
Thompson, Matthew
Venue
BMJ Open
Publisher
BMJ
Published
2014-04
Volume
4
Issue
5
Pages
e004565
ISSN
2044-6055 (ISSN-L)
OpenAlex
W2161884253
Cited by
106
References
28
Citations by year
2026: 1 · 2025: 3 · 2024: 8 · 2023: 5 · 2022: 12 · 2021: 19 · 2020: 7 · 2019: 10 · 2018: 10 · 2017: 12 · 2016: 13 · 2015: 3 · 2014: 3
FWCI
7.09
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • BMJ Open (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • HighWire Press Open Archive (submittedVersion)
Funders
  • National Institute for Health and Care Research (NF-SI-0611-10273, RP-PG-0407-10347)
  • Programme Grants for Applied Research
  • NIHR School for Primary Care Research
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Health Promotion and Cardiovascular Prevention
Keywords
atrial fibrillation, triage test, single-lead ECG, blood pressure monitors, diagnostic accuracy, primary care, elderly patients, stroke risk, arrhythmia screening, 12-lead ECG
MeSH terms
Aged, Aged, 80 and over, Atrial Fibrillation, Blood Pressure Determination, Electrocardiography, Female, Humans, Male, Primary Health Care, Triage, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Triage tests for identifying atrial fibrillation in primary care: a diagnostic accuracy study comparing single-lead ECG and modified BP monitors. https://app.cochat.ai/papers/10.1136/bmjopen-2013-004565
The paper
Kearley, K., Selwood, M., Van den Bruel, A., Thompson, M., Mant, D., Hobbs, F. R., Fitzmaurice, D., & Heneghan, C. (2014). Triage tests for identifying atrial fibrillation in primary care: a diagnostic accuracy study comparing single-lead ECG and modified BP monitors. BMJ Open. https://doi.org/10.1136/bmjopen-2013-004565

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.