CoChat

Exercise and Sport Performance with Low Doses of Caffeine

Open access
Spriet, Lawrence L. · 2014 · Sports Medicine

The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.

Abstract

Caffeine is a popular work-enhancing supplement that has been actively researched since the 1970s. The majority of research has examined the effects of moderate to high caffeine doses (5-13 mg/kg body mass) on exercise and sport. These caffeine doses have profound effects on the responses to exercise at the whole-body level and are associated with variable results and some undesirable side effects. Low doses of caffeine (<3 mg/kg body mass, ~200 mg) are also ergogenic in some exercise and sport situations, although this has been less well studied. Lower caffeine doses (1) do not alter the peripheral whole-body responses to exercise; (2) improve vigilance, alertness, and mood and cognitive processes during and after exercise; and (3) are associated with few, if any, side effects. Therefore, the ergogenic effect of low caffeine doses appears to result from alterations in the central nervous system. However, several aspects of consuming low doses of caffeine remain unresolved and suffer from a paucity of research, including the potential effects on high-intensity sprint and burst activities. The responses to low doses of caffeine are also variable and athletes need to determine whether the ingestion of ~200 mg of caffeine before and/or during training and competitions is ergogenic on an individual basis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s40279-014-0257-8

Cites

80 of 80 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Plasma caffeine concentrations for 1 h at rest and during exercise to exhaustion at 80–85 % of maximum oxygen uptake in recreationally active subjects after the consumption of a placebo (open circles), or 3 (filled squares), 6 (filled triangles) or 9 (filled circles) mg/kg body mass of caffeine. Data are means ± standard error (n = 8). exh exhaustion (reproduced from Graham and Spriet [2], with permission)
Fig. 1 Plasma caffeine concentrations for 1 h at rest and during exercise to exhaustion at 80–85 % of maximum oxygen uptake in recreationally active subjects after the consumption of a placebo (open circles), or 3 (filled squares), 6 (filled triangles) or 9 (filled circles) mg/kg body mass of caffeine. Data are means ± standard error (n = 8). exh exhaustion (reproduced from Graham and Spriet [2], with permission)CC BY · PubMed Central
Fig. 2 Effects of ingesting no caffeine (0) or 3, 6 or 9 mg/kg body mass of caffeine (dose) on running time to exhaustion at ~85 % of maximum oxygen uptake. Data are means ± standard error (n = 8). Bars with different letters are significantly different, and bars with the same letters are not significantly different (reproduced from Graham and Spriet [2], with permission)
Fig. 2 Effects of ingesting no caffeine (0) or 3, 6 or 9 mg/kg body mass of caffeine (dose) on running time to exhaustion at ~85 % of maximum oxygen uptake. Data are means ± standard error (n = 8). Bars with different letters are significantly different, and bars with the same letters are not significantly different (reproduced from Graham and Spriet [2], with permission)CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 80 references

Cited by

See all 421

Metadata

Authors
Spriet, L. L.
Affiliations
University of Guelph (CA)
Corresponding author
Spriet, Lawrence L.
Venue
Sports Medicine
Published
2014-10-30
Volume
44
Issue
S2
Pages
175-184
ISSN
  • 0112-1642 (ISSN-L)
  • 1179-2035
OpenAlex
W1980412809
Cited by
347
References
80
Citations by year
2026: 46 · 2025: 28 · 2024: 34 · 2023: 15 · 2022: 36 · 2021: 27 · 2020: 28 · 2019: 35 · 2018: 39 · 2017: 21 · 2016: 30 · 2015: 7
FWCI
2.48
Type
journal article
Language
en
Open access
Locations
  • Sports Medicine (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
World Anti-Doping Agency
Topics
  • Health Sciences › Medicine › Pharmacology (medical) › Coffee research and impacts
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
Keywords
caffeine, low-dose caffeine, ergogenic aids, exercise performance, athletic performance, central nervous system, sustained attention, alertness, mood, cognitive performance, caffeine side effects, interindividual variability
MeSH terms
Affect, Caffeine, Cognition, Humans, Physical Endurance, Exercise, Dietary Supplements, Athletic Performance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Exercise and Sport Performance with Low Doses of Caffeine. https://app.cochat.ai/papers/10.1007/s40279-014-0257-8
The paper
Spriet, L. L. (2014). Exercise and Sport Performance with Low Doses of Caffeine. Sports Medicine. https://doi.org/10.1007/s40279-014-0257-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.