Laser-Induced Graphene: En Route to Smart Sensing
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The discovery of laser-induced graphene (LIG) from polymers in 2014 has aroused much attention in recent years. A broad range of applications, including batteries, catalysis, sterilization, and separation, have been explored. The advantages of LIG technology over conventional graphene synthesis methods are conspicuous, which include designable patterning, environmental friendliness, tunable compositions, and controllable morphologies. In addition, LIG possesses high porosity, great flexibility, and mechanical robustness, and excellent electric and thermal conductivity. The patternable and printable manufacturing process and the advantageous properties of LIG illuminate a new pathway for developing miniaturized graphene devices. Its use in sensing applications has grown swiftly from a single detection component to an integrated smart detection system. In this minireview, we start with the introduction of synthetic efforts related to the fabrication of LIG sensors. Then, we highlight the achievement of LIG sensors for the detection of a diversity of stimuli with a focus on the design principle and working mechanism. Future development of the techniques toward in situ and smart detection of multiple stimuli in widespread applications will be discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270
Self-citation
Cited by
Age of Flexible Electronics: Emerging Trends in Soft Multifunctional Sensors
Lee, J., Cho, K., & Kim, J. (2024) · Advanced Materials · doi:10.1002/adma.202310505 · Cited by 355
Advances in Graphene-Based Electrode for Triboelectric Nanogenerator
Xie, B., Guo, Y., Chen, Y., Zhang, H., Xiao, J., Hou, M., Liu, H., Ma, L., Chen, X., & Wong, C. (2025) · Nano-Micro Letters · doi:10.1007/s40820-024-01530-1 · Cited by 193
“The favorable electrical conductivity, porous structure, and dopant modulation of LIG hold substantial promise in the realm of flexible wearable electronics and TENG applications [78, 79].”
Direct Synthesis of Ammonia from Nitrate on Amorphous Graphene with Near 100% Efficiency
Huang, L., Cheng, L., Ma, T., Zhang, J., Wu, H., Su, J., Song, Y., Zhu, H., Liu, Q., Zhu, M., et al. (2023) · Advanced Materials · doi:10.1002/adma.202211856 · Cited by 185
Self-citationLaser-Induced Graphene Based Flexible Electronic Devices
Wang, H., Zhao, Z., Liu, P., & Guo, X. (2022) · Biosensors · doi:10.3390/bios12020055 · Cited by 164
A Flexible Electrochemical Biosensor Based on NdNiO3 Nanotubes for Ascorbic Acid Detection
Rossato, J. H. H., Oliveira, M. E., Lopes, B. V., Gallo, B. B., La Rosa, A. B., Piva, E., Barba, D., Rosei, F., Carreño, N. L. V., & Escote, M. T. (2022) · ACS Applied Nano Materials · doi:10.1021/acsanm.1c03992 · Cited by 29
Metadata
- Authors
- Huang, L., Su, J., Song, Y., & Ye, R.
- Venue
- Nano-Micro Letters
- Published
- 2020-08-03
- Volume
- 12
- Issue
- 1
- Pages
- 157-157
- ISSN
- 2150-5551 (ISSN-L)
- 2311-6706
- OpenAlex
- W3047619633
- Cited by
- 246
- References
- 1
- FWCI
- 11.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.