Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 50 of the 53 references it cites were found in a registry or an index.

A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat

Abstract

Wearable sweat sensors have the potential to provide continuous measurements of useful biomarkers. However, current sensors cannot accurately detect low analyte concentrations, lack multimodal sensing or are difficult to fabricate at large scale. We report an entirely laser-engraved sensor for simultaneous sweat sampling, chemical sensing and vital-sign monitoring. We demonstrate continuous detection of temperature, respiration rate and low concentrations of uric acid and tyrosine, analytes associated with diseases such as gout and metabolic disorders. We test the performance of the device in both physically trained and untrained subjects under exercise and after a protein-rich diet. We also evaluate its utility for gout monitoring in patients and healthy controls through a purine-rich meal challenge. Levels of uric acid in sweat were higher in patients with gout than in healthy individuals, and a similar trend was observed in serum.

Overview

Integrity signals

Registry

Crossref · 10.1038/s41587-019-0321-x

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Show all 53 references

Cited by

See all 1,270

Metadata

Authors
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., Hsiai, T. K., Li, Z., & Gao, W.
Affiliations
  • California Institute of Technology (US)
  • Santa Clara University (US)
  • Princeton University (US)
  • Peking University (CN)
  • University of California, Los Angeles (US)
Corresponding author
Gao, Wei
Venue
Nature Biotechnology
Published
2019-11-25
Volume
38
Issue
2
Pages
217-224
ISSN
  • 0733-222X (ISSN-L)
  • 1087-0156
  • 1546-1696
OpenAlex
W2990605642
Cited by
1,270
References
53
Citations by year
2026: 139 · 2025: 208 · 2024: 236 · 2023: 208 · 2022: 190 · 2021: 186 · 2020: 102 · 2019: 1
FWCI
42.16
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Nature Biotechnology (publishedVersion)
  • PubMed (publishedVersion)
  • CaltechAUTHORS (California Institute of Technology) (submittedVersion)
Funders
American Heart Association (19TPA34850157)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
Keywords
wearable sensors, laser engraving, sweat analysis, uric acid, tyrosine, vital signs monitoring, temperature sensing, respiration rate, purine-rich diet, physical activity, biomarker detection, low-concentration analyte detection
MeSH terms
Wearable Electronic Devices, Adolescent, Adult, Aged, Equipment Design, Gout, Humans, Lasers, Middle Aged, Skin, Sweat, Temperature, Tyrosine, Uric Acid, Reproducibility of Results, Microfluidics, Young Adult, Vital Signs

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat. https://app.cochat.ai/papers/10.1038/s41587-019-0321-x
The paper
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., Hsiai, T. K., Li, Z., & Gao, W. (2020). A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat. Nature Biotechnology. https://doi.org/10.1038/s41587-019-0321-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.