The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Highly Sensitive Pseudocapacitive Iontronic Pressure Sensor with Broad Sensing Range
Open accessAbstract
Highlights: The iontronic pressure sensor achieved an ultrahigh sensitivity (Smin > 200 kPa−1, Smax > 45,000 kPa−1). The iontronic pressure sensor exhibited a broad sensing range of over 1.4 MPa. Pseudocapacitive iontronic pressure sensor using MXene was proposed. Flexible pressure sensors are unprecedentedly studied on monitoring human physical activities and robotics. Simultaneously, improving the response sensitivity and sensing range of flexible pressure sensors is a great challenge, which hinders the devices’ practical application. Targeting this obstacle, we developed a Ti 3 C 2 T x-derived iontronic pressure sensor (TIPS) by taking the advantages of the high intercalation pseudocapacitance under high pressure and rationally designed structural configuration. TIPS achieved an ultrahigh sensitivity (Smin > 200 kPa−1, Smax > 45,000 kPa−1) in a broad sensing range of over 1.4 MPa and low limit of detection of 20 Pa as well as stable long-term working durability for 10,000 cycles. The practical application of TIPS in physical activity monitoring and flexible robot manifested its versatile potential. This study provides a demonstration for exploring pseudocapacitive materials for building flexible iontronic sensors with ultrahigh sensitivity and sensing range to advance the development of high-performance wearable electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270
Self-citationLearning the signatures of the human grasp using a scalable tactile glove
Sundaram, S., Kellnhofer, P., Li, Y., Zhu, J.-Y., Torralba, A., & Matusik, W. (2019) · Nature · doi:10.1038/s41586-019-1234-z · Cited by 1,162
Skin-integrated wireless haptic interfaces for virtual and augmented reality
Yu, X., Xie, Z., Yu, Y., Lee, J., Vazquez-Guardado, A., Luan, H., Ruban, J., Ning, X., Akhtar, A., Li, D., et al. (2019) · Nature · doi:10.1038/s41586-019-1687-0 · Cited by 1,025
Electronic skins and machine learning for intelligent soft robots
Shih, B., Shah, D., Li, J., Thuruthel, T. G., Park, Y.-L., Iida, F., Bao, Z., Kramer-Bottiglio, R., & Tolley, M. T. (2020) · Science Robotics · doi:10.1126/scirobotics.aaz9239 · Cited by 715
Yu, Y., Nassar, J., Xu, C., Min, J., Yang, Y., Dai, A., Doshi, R., Huang, A., Song, Y., Gehlhar, R., et al. (2020) · Science Robotics · doi:10.1126/scirobotics.aaz7946 · Cited by 655
Machine-knitted washable sensor array textile for precise epidermal physiological signal monitoring
Fan, W., He, Q., Meng, K., Tan, X., Zhou, Z., Zhang, G., Yang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aay2840 · Cited by 516
Huang, Y.-C., Liu, Y., Ma, C., Cheng, H.-C., He, Q., Wu, H., Wang, C., Lin, C.-Y., Huang, Y., & Duan, X. (2020) · Nature Electronics · doi:10.1038/s41928-019-0356-5 · Cited by 233
Cited by
Recent Advances in Flexible Pressure Sensors Based on MXene Materials
Qin, R., Nong, J., Wang, K., Liu, Y., Zhou, S., Hu, M., Zhao, H., & Shan, G. (2024) · Advanced Materials · doi:10.1002/adma.202312761 · Cited by 416
Self-citationYang, R., Dutta, A., Li, B., Tiwari, N., Zhang, W., Niu, Z., Gao, Y., Erdely, D., Xin, X., Li, T., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-38274-2 · Cited by 390
Shi, Z., Meng, L., Shi, X., Li, H., Zhang, J., Sun, Q., Liu, X., Chen, J., & Liu, S. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00874-w · Cited by 282
Flexible capacitive pressure sensors for wearable electronics
Wang, H., Li, Z., Liu, Z., Fu, J., Shan, T., Yang, X., Lei, Q., Yang, Y., & Li, D. (2022) · Journal of Materials Chemistry C · doi:10.1039/d1tc05304c · Cited by 263
Metadata
- Authors
- Gao, L., Wang, M., Wang, W., Xu, H., Wang, Y., Zhao, H., Cao, K., Xu, D., & Li, L.
- Venue
- Nano-Micro Letters
- Published
- 2021-06-11
- Volume
- 13
- Issue
- 1
- Pages
- 140-140
- ISSN
- 2150-5551 (ISSN-L)
- 2311-6706
- OpenAlex
- W3170662839
- Cited by
- 165
- References
- 7
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive Pseudocapacitive Iontronic Pressure Sensor with Broad Sensing Range. https://app.cochat.ai/papers/10.1007/s40820-021-00664-w
- The paper
- Gao, L., Wang, M., Wang, W., Xu, H., Wang, Y., Zhao, H., Cao, K., Xu, D., & Li, L. (2021). Highly Sensitive Pseudocapacitive Iontronic Pressure Sensor with Broad Sensing Range. Nano-Micro Letters. https://doi.org/10.1007/s40820-021-00664-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.