Metals for bone implants: safety, design, and efficacy
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
Like most bone deficits, mandibular segmental defects may result from surgical reconstruction due to congenital deformity, tumor resection, other pathologies, senescence, trauma, or infection. The goals of mandibular reconstruction are to restore the mandible’s function and normal appearance. Clinical methods to restore the mandible typically rely on bone replacement using some combination of bone tissue transfer and metal implants. This paper reviews the safety, design, and efficacy of metal implants in general and specifically for the repair of mandibular segmental defects. These problems include implant incorporation, implant failure mechanisms (e.g., stress concentration, stress shielding), corrosion and toxicity, infection, and muscle re-attachment. Finally, this paper presents the use of porous nickel-titanium (NiTi) implants for the repair of skeletal defects through the example of mandibular segmental defects. Resorbable magnesium, and porous and non-porous NiTi, immobilization hardware are also discussed. These materials provide new options which may better match the material properties, and if they can be 3D printed, better match the shape of surrounding host tissue. These advances might reduce engrafted bone and metal implant failure and restore musculoskeletal function for the long term. Patient-specific hardware and grafting strategies might prove to be useful tools in determining both the patient’s appearance and functional outcome following reconstructive musculoskeletal surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452 · cited 1×
“5 of Part 1 of this review, the possibility of resorbable metallic fracture fixation is the topic of much research activity [5, 6].”
BackgroundBiodegradable polymers as biomaterials
Nair, L. S., & Laurencin, C. T. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.017 · Cited by 4,416
Surface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487 · cited 1×
“The reason that cemented implants are not as favorable is that they may transfer high levels of heat into the body which may cause harmful damage [60].”
BackgroundOn the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772 · cited 1×
“However, surface texture, in the form of roughness and/or porosity, can improve implant incorporation [15].”
BackgroundOsseointegration and its experimental background
Branemark, P.-I. (1983) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(83)80101-2 · Cited by 2,084
The development of binary Mg–Ca alloys for use as biodegradable materials within bone
Li, Z., Gu, X., Lou, S., & Zheng, Y. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.021 · Cited by 1,593 · cited 1×
“Recent studies have shown that non-toxic alloying elements such as Ca and Zr can significantly decrease the corrosion rate of Mg alloys [8, 39].”
BackgroundTiO2 nanotubes: Self-organized electrochemical formation, properties and applications
Macak, J. M., Tsuchiya, H., Ghicov, A., Yasuda, K., Hahn, R., Bauer, S., & Schmuki, P. (2007) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2007.08.004 · Cited by 1,415
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343 · cited 2×
“Recent studies have shown that non-toxic alloying elements such as Ca and Zr can significantly decrease the corrosion rate of Mg alloys [8, 39].”
BackgroundAlbrektsson, T. O., & Wennerberg, A. (2004) · PubMed · Cited by 1,118
Martin, J. Y., Schwartz, Z., Hummert, T. W., Schraub, D. M., Simpson, J., Lankford, J., Dean, D. D., Cochran, D. L., & Boyan, B. D. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290314 · Cited by 1,111
Self-citation
Cited by
A comprehensive review on metallic implant biomaterials and their subtractive manufacturing
Davis, R., Singh, A., Jackson, M. J., Coelho, R. T., Prakash, D., Charalambous, C. P., Ahmed, W., da Silva, L. R. R., & Lawrence, A. A. (2022) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-022-08770-8 · Cited by 380
Bairagi, D., & Mandal, S. (2022) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.09.005 · Cited by 272
Recent Advancements in Materials and Coatings for Biomedical Implants
Amirtharaj Mosas, K. K., Chandrasekar, A. R., Dasan, A., Pakseresht, A., & Galusek, D. (2022) · Gels · doi:10.3390/gels8050323 · Cited by 256
A Review on Additive Manufacturing of Shape-Memory Materials for Biomedical Applications
Sabahi, N., Chen, W., Wang, C.-H., Kruzic, J. J., & Li, X. (2020) · JOM · doi:10.1007/s11837-020-04013-x · Cited by 195
Bone Tissue Engineering via Carbon‐Based Nanomaterials
Peng, Z., Zhao, T., Zhou, Y., Li, S., Li, J., & Leblanc, R. M. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901495 · Cited by 187
Onal, E., Frith, J., Jurg, M., Wu, X., & Molotnikov, A. (2018) · Metals · doi:10.3390/met8040200 · Cited by 172
“The mismatch between the modulus of the bone and the implant results in the failure of the implant in the long-term due to the stress-shielding problem [6].”
BackgroundMartinez, D. C., Borkam-Schuster, A., Helmholz, H., Dobkowska, A., Luthringer-Feyerabend, B., Płociński, T., Willumeit-Römer, R., & Święszkowski, W. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2024.08.015 · Cited by 21
Metadata
- Authors
- Shayesteh Moghaddam, N., Taheri Andani, M., Amerinatanzi, A., Haberland, C., Huff, S., Miller, M., Elahinia, M., & Dean, D.
- Venue
- Biomanufacturing Reviews
- Published
- 2016-10-06
- Volume
- 1
- Issue
- 1
- ISSN
- 2363-507X (ISSN-L)
- 2363-5088
- OpenAlex
- W2528726436
- Cited by
- 184
- References
- 62
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.