The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly sensitive electrochemical detection of cholesterol based on Au–Pt NPs/PAMAM–ZIF-67 nanomaterials
Abstract
A cholesterol biosensor was constructed by bimetallic (Au and Pt) and poly(amidoamine)-zeolite imidazole framework (PAMAM–ZIF-67). First, PAMAM–ZIF-67 nanomaterial was immobilized onto the electrode, and then Au and Pt were modified on the electrode by the electro-deposition method. Subsequently, cholesterol oxidase (ChOx) and cholesterol esterase (ChEt) were fixed on the electrode. The stepwise modification procedures were recorded by impedance spectroscopy and voltammetry. The current response presented a linear relation to the logarithm of cholesterol content when content ranged between 0.00015 and 10.24 mM, and the minimum detection concentration reached 3 nM. The electrode was also used for the cholesterol assay in serum, which hinted at its potentially valuable in clinical diagnostics. Graphical abstract An electrochemical biosensor based on gold nanoparticles, platinum nanoparticles, and polyamide–zeolitic imidazolate frameworks was developed for detection of cholesterol. First, polyamide–zeolitic imidazolate frameworks nanomaterial was fixed onto the electrode modified of mercaptopropionic acid by Au–S bond. Then, gold nanoparticles and platinum nanoparticles were electrodeposited on the above electrode. Subsequently, cholesterol oxidase and cholesterol esterase were co-immobilized on the surface of the modified electrode to fabricate the cholesterol biosensor. The biosensor has also been used for the measurement of cholesterol in human serum, which implied potential applications in biotechnology and clinical diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Novel Aldehyde-Terminated Dendrimers: Synthesis and Cytotoxicity Assay
Hamidi, A., Sharifi, S., Davaran, S., Ghasemi, S., Omidi, Y., & Rashidi, M.-R. (2012) · Tabriz University of Medical Sciences · doi:10.5681/bi.2012.014 · Cited by 34
Research works printed but not linked: 36
- U. Saxena, A. Das, Nanomaterials towards fabrication of cholesterol biosensors: key roles and design approaches. Biosens. Bioelectron. 75, 196–205 (2016) · DOI
- E. Ikonen, Cellular cholesterol trafficking and compartmentalization. Nat. Rev. Mol. Cell Biol. 9, 125–138 (2008) · DOI · Paper page
- N. Batra, M. Tomar, V. Gupta, ZnO–CuO composite matrix based reagentless biosensor for detection of total cholesterol. Biosens. Bioelectron. 67, 263–271 (2015) · doi:10.1016/j.bios.2014.08.029
- C. Zhao, L. Wan, L. Jiang, Q. Wang, K. Jiao, Highly sensitive and selective cholesterol biosensor based on direct electron transfer of hemoglobin. Anal. Biochem. 383, 25–30 (2008) · DOI
- Y.J. Lee, J.Y. Park, Nonenzymatic free-cholesterol detection via a modified highly sensitive macroporous gold electrode with platinum nanoparticles. Biosens. Bioelectron. 26, 1353–1358 (2010) · DOI
- A.N. Sekretaryova, V. Beni, M. Eriksson, A.A. Karyakin, A.P. Turner, M.Y. Vagin, Cholesterol self-powered biosensor. Anal. Chem. 86, 9540–9547 (2014) · DOI · Paper page
- S. Komathi, N. Muthuchamy, K.P. Lee, A.I. Gopalan, Fabrication of a novel dual mode cholesterol biosensor using titanium dioxide nanowire bridged 3D graphene nanostacks. Biosens. Bioelectron. 84, 64–71 (2016) · doi:10.1016/j.bios.2015.11.042
- J.L. García, I. Uhía, B. Galán, Catabolism and biotechnological applications of cholesterol degrading bacteria. Microb. Biotechnol. 5, 679–699 (2012) · DOI · Paper page
- V. Shumyantseva, G. Deluca, T. Bulko, S. Carrara, C. Nicolini, S.A. Usanov, A. Archakov, Cholesterol amperometric biosensor based on cytochrome P450scc. Biosens. Bioelectron. 19, 971–976 (2004) · DOI
- N.R. Nirala, S. Abraham, V. Kumar, S.A. Pandey, U. Yadav, M. Srivastava, S.K. Srivastava, V.N. Singh, A.M. Kayastha, A. Srivastava, P.S. Saxena, Partially reduced graphene oxide-gold nanorods composite based bioelectrode of improved sensing performance. Talanta 144, 745–754 (2015) · DOI
- C.R. Jefcoate, J. Lee, Cholesterol signaling in single cells: lessons from STAR and sm-FISH. J. Mol. Endocrinol. 60, R213-r235 (2018) · DOI
- K. Hojo, H. Hakamata, F. Kusu, Simultaneous determination of serum lathosterol and cholesterol by semi-micro high-performance liquid chromatography with electrochemical detection. J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 879, 751–755 (2011) · DOI
- R.G. Mahmudunnabi, F.Z. Farhana, N. Kashaninejad, S.H. Firoz, Y.B. Shim, M.J.A. Shiddiky, Nanozyme-based electrochemical biosensors for disease biomarker detection. Analyst 145, 4398–4420 (2020) · DOI · Paper page
- B.K. Shrestha, R. Ahmad, S. Shrestha, C.H. Park, C.S. Kim, In situ synthesis of cylindrical spongy polypyrrole doped protonated graphitic carbon nitride for cholesterol sensing application. Biosens. Bioelectron. 94, 686–693 (2017) · DOI
- J. Schweicher, T.A. Desai, Facile synthesis of robust free-standing TiO(2) nanotubular membranes for biofiltration applications. J. Appl. Electrochem. 44, 411–418 (2014) · doi:10.1007/s10800-013-0643-1
- R. Ahmad, N. Tripathy, Y.B. Hahn, High-performance cholesterol sensor based on the solution-gated field effect transistor fabricated with ZnO nanorods. Biosens. Bioelectron. 45, 281–286 (2013) · doi:10.1016/j.bios.2013.01.021
- Y. Huang, L. Cui, Y. Xue, S. Zhang, N. Zhu, J. Liang, G. Li, Ultrasensitive cholesterol biosensor based on enzymatic silver deposition on gold nanoparticles modified screen-printed carbon electrode. Mater. Sci. Eng. C Mater. Biol. Appl. 77, 1–8 (2017) · doi:10.1016/j.msec.2017.03.253
- G. Li, J.M. Liao, G.Q. Hu, N.Z. Ma, P.J. Wu, Study of carbon nanotube modified biosensor for monitoring total cholesterol in blood. Biosens. Bioelectron. 20, 2140–2144 (2005) · doi:10.1016/j.bios.2004.09.005
- H. Furukawa, K.E. Cordova, M. O’Keeffe, O.M. Yaghi, The chemistry and applications of metal–organic frameworks. Science 341, 1230444 (2013) · DOI · Paper page
- A. Muhammad, A. Kanwal, M.R. Md, D. Salvatore, C. Vincenzo, R. Flavio, Glucose detection devices and methods based on metal–organic frameworks and related materials. Adv. Funcy. Mater. 31, 2106023–2106079 (2021) · DOI · Paper page
- J. Yang, Y.W. Yang, Metal–organic frameworks for biomedical applications. Small 16, e1906846 (2020) · DOI · Paper page
- J. Zhang, Y. Tan, W.J. Song, Zeolitic imidazolate frameworks for use in electrochemical and optical chemical sensing and biosensing: a review. Mikrochim. Acta 187, 234 (2020) · doi:10.1007/s00604-020-4173-3
- S. Gao, Y. Jin, K. Ge, Z. Li, H. Liu, X. Dai, Y. Zhang, S. Chen, X. Liang, J. Zhang, Self-supply of O(2) and H(2)O(2) by a nanocatalytic medicine to enhance combined chemo/chemodynamic therapy. Adv. Sci. (Weinh) 6, 1902137 (2019) · DOI · Paper page
- X. Li, Y. Du, H. Wang, H. Ma, D. Wu, X. Ren, Q. Wei, J.J. Xu, Self-supply of H(2)O(2) and O(2) by hydrolyzing CaO(2) to enhance the electrochemiluminescence of luminol based on a closed bipolar electrode. Anal. Chem. 92, 12693–12699 (2020) · doi:10.1021/acs.analchem.0c03170
- Y. Li, J.T. Cox, B. Zhang, Electrochemical responses and electrocatalysis at single au nanoparticles. J. Am. Chem. Soc. 132, 3047–3054 (2010) · DOI · Paper page
- A. Safavi, F. Farjami, Electrodeposition of gold-platinum alloy nanoparticles on ionic liquid-chitosan composite film and its application in fabricating an amperometric cholesterol biosensor. Biosens. Bioelectron. 26, 2547–2552 (2011) · doi:10.1016/j.bios.2010.11.002
- Z. Bai, G. Li, J. Liang, J. Su, Y. Zhang, H. Chen, Y. Huang, W. Sui, Y. Zhao, Non-enzymatic electrochemical biosensor based on Pt NPs/RGO-CS-Fc nano-hybrids for the detection of hydrogen peroxide in living cells. Biosens. Bioelectron. 82, 185–194 (2016) · doi:10.1016/j.bios.2016.04.004
- M. Zhang, R. Yuan, Y. Chai, S. Chen, H. Zhong, C. Wang, Y. Cheng, A biosensor for cholesterol based on gold nanoparticles-catalyzed luminol electrogenerated chemiluminescence. Biosens. Bioelectron. 32, 288–292 (2012) · doi:10.1016/j.bios.2011.12.008
- Y. Yi, W. Zhao, Z. Zeng, C. Wei, C. Lu, Y. Shao, W. Guo, S. Dou, J. Sun, ZIF-8@ZIF-67-Derived nitrogen-doped porous carbon confined CoP polyhedron targeting superior potassium-ion storage. Small 16, e1906566 (2020) · DOI · Paper page
- J. Liu, W. Zhang, M. Peng, G. Ren, L. Guan, K. Li, Y. Lin, ZIF-67 as a template generating and tuning “raisin pudding”-type nanozymes with multiple enzyme-like activities: toward online electrochemical detection of 3,4-dihydroxyphenylacetic acid in living brains. ACS Appl. Mater. Interfaces 12, 29631–29640 (2020)
- S. Aravamudhan, A. Kumar, S. Mohapatra, S. Bhansali, Sensitive estimation of total cholesterol in blood using Au nanowires based micro-fluidic platform. Biosens. Bioelectron. 22, 2289–2294 (2007) · DOI
- A.A. Ansari, P.R. Solanki, B.D. Malhotra, Hydrogen peroxide sensor based on horseradish peroxidase immobilized nanostructured cerium oxide film. J. Biotechnol. 142, 179–184 (2009) · DOI
- J. Singh, M. Srivastava, A. Roychoudhury, D.W. Lee, S.H. Lee, B.D. Malhotra, Bienzyme-functionalized monodispersed biocompatible cuprous oxide/chitosan nanocomposite platform for biomedical application. J. Phys. Chem. B 117, 141–152 (2013) · doi:10.1021/jp309639w
- L. Zhu, L. Xu, L. Tan, H. Tan, S. Yang, S. Yao, Direct electrochemistry of cholesterol oxidase immobilized on gold nanoparticles-decorated multiwalled carbon nanotubes and cholesterol sensing. Talanta 106, 192–199 (2013) · DOI
- S. Soylemez, S.O. Hacioglu, M. Kesik, H. Unay, A. Cirpan, L. Toppare, A novel and effective surface design: conducting polymer/β-cyclodextrin host–guest system for cholesterol biosensor. ACS Appl. Mater. Interfaces 6, 18290–18300 (2014) · doi:10.1021/am5054493
- R.S. Dey, C.R. Raj, Redox-functionalized graphene oxide architecture for the development of amperometric biosensing platform. ACS Appl. Mater. Interfaces 5, 4791–4798 (2013) · DOI
Metadata
- Authors
- Zhang, L., Zhu, J., Hong, W., & Li, G.
- Venue
- Analytical Sciences
- Published
- 2023-09-25
- Volume
- 40
- Issue
- 1
- Pages
- 37-45
- ISSN
- 0910-6340
- 1348-2246
- Cited by
- 24
- References
- 1
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Funders
- Zhejiang Provincal Natural Science Foundation of China (LQ20H160012)
- Medicine and Health Research Foundation of Zhejiang Province (2021KY272)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly sensitive electrochemical detection of cholesterol based on Au–Pt NPs/PAMAM–ZIF-67 nanomaterials. https://app.cochat.ai/papers/10.1007/s44211-023-00427-0
- The paper
- Zhang, L., Zhu, J., Hong, W., & Li, G. (2024). Highly sensitive electrochemical detection of cholesterol based on Au–Pt NPs/PAMAM–ZIF-67 nanomaterials. Analytical Sciences. https://doi.org/10.1007/s44211-023-00427-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.