Comparison of transthoracic and transesophageal echocardiography for detection of abnormalities of prosthetic and bioprosthetic valves in the mitral and aortic positions
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Two-dimensional echocardiography is the diagnostic procedure of choice for evaluation of prosthetic valve abnormalities. However, transthoracic echocardiography (TTE) may be limited owing to acoustic shadowing and poor acoustic windows. Some of these limitations may be overcome by transesophageal echocardiography (TEE). One hundred twenty-six patients with 148 prosthetic valves (113 bioprostheses and 35 mechanical devices) were studied by M-mode and 2-dimensional TTE and TEE. Prosthetic valve morphology was confirmed by surgery or autopsy in all cases; 124 prostheses were classified as diseased (33 endocarditis, 8 thrombi, and 83 degeneration defined as leaflet thickening > 3 mm with restricted motion) and 24 as normal. Prosthetic valve endocarditis and thrombi were correctly identified by TTE in 12 of 33 (36%) and 1 of 8 (13%) prostheses, respectively, but could be diagnosed by TEE in 27 of 33 (82%; p < 0.001) and 8 of 8 (100%; p < 0.01), respectively. Compared with TTE, TEE had a higher sensitivity for morphologic prosthetic valve abnormalities in patients with either bioprostheses (88 [87%] vs 66 [65%] of 101 prostheses; p < 0.01) or mechanical devices (19 [83%] vs 5 [22%] of 23 prostheses; p < 0.01) and in patients with a prosthesis in either the aortic (49 [77%] vs 32 [50%] of 64; p < 0.01) or mitral (58 [97%] vs 39 [65%] of 60; p < 0.001) position. Overall, sensitivity and specificity were 57 and 63%, respectively, for TTE, and 86 and 88%, respectively, for TEE.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the setting of a prosthetic valve, transthoracic images are greatly hampered by the structural components of the prosthesis and are inadequate for assessment of the perivalvular area where those infections often start.48”
Citations
Cites
Safety of transesophageal echocardiography. A multicenter survey of 10,419 examinations.
Daniel, W. G., Erbel, R., Kasper, W., Visser, C. A., Engberding, R., Sutherland, G. R., Grube, E., Hanrath, P., Maisch, B., & Dennig, K. (1991) · Circulation · doi:10.1161/01.cir.83.3.817 · Cited by 825
Self-citationSEWARD, J. B., KHANDHERIA, B. K., OH, J. K., ABEL, M. D., HUGHES, R. W., EDWARDS, W. D., NICHOLS, B. A., FREEMAN, W. K., & TAJIK, A. J. (1988) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)65529-3 · Cited by 791
Daniel, W. G., Mügge, A., Martin, R. P., Lindert, O., Hausmann, D., Nonnast-Daniel, B., Laas, J., & Lichtlen, P. R. (1991) · New England Journal of Medicine · doi:10.1056/nejm199103213241203 · Cited by 723
Self-citationMügge, A., Daniel, W. G., Frank, G., & Lichtlen, P. R. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90104-6 · Cited by 654
Self-citationFrazin, L., Talano, J. V., Stephanides, L., Loeb, H. S., Kopel, L., & Gunnar, R. M. (1976) · Circulation · doi:10.1161/01.cir.54.1.102 · Cited by 300
Schluter, M., Langenstein, B. A., Polster, J., Kremer, P., Souquet, J., Engel, S., & Hanrath, P. (1982) · Heart · doi:10.1136/hrt.48.1.67 · Cited by 168
Normal and abnormal prosthetic valve function as assessed by doppler echocardiography
Panidis, I. P., Ross, J., & Mintz, G. S. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80046-8 · Cited by 165
Nellessen, U., Schnittger, I., Appleton, C. P., Masuyama, T., Bolger, A., Fischell, T. A., Tye, T., & Popp, R. L. (1988) · Circulation · doi:10.1161/01.cir.78.4.848 · Cited by 165
Value and limitations of transesophageal echocardiography in assessment of mitral valve prostheses.
Khandheria, B. K., Seward, J. B., Oh, J. K., Freeman, W. K., Nichols, B. A., Sinak, L. J., Miller, F. A., & Tajik, A. J. (1991) · Circulation · doi:10.1161/01.cir.83.6.1956 · Cited by 141
Doppler echocardiographic evaluation of Hancock and Björk-Shiley prosthetic valves
Sagar, K. B., Wann, L. S., Paulsen, W., & Romhilt, D. W. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80480-6 · Cited by 119
Cited by
2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.536 · Cited by 3,523
Baddour, L. M., Wilson, W. R., Bayer, A. S., Fowler, V. G., Tleyjeh, I. M., Rybak, M. J., Barsic, B., Lockhart, P. B., Gewitz, M. H., Levison, M. E., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000296 · Cited by 3,232
“ment of the perivalvular area where those infections often start.(48) Although cost-effectiveness calculations suggest that”
BackgroundNishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000031 · Cited by 2,905
Baddour, L. M., Wilson, W. R., Bayer, A. S., Fowler, V. G., Bolger, A. F., Levison, M. E., Ferrieri, P., Gerber, M. A., Tani, L. Y., Gewitz, M. H., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.165564 · Cited by 1,707
2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
Infective Endocarditis in Adults
Mylonakis, E., & Calderwood, S. B. (2001) · New England Journal of Medicine · doi:10.1056/nejmra010082 · Cited by 1,324
Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound
Zoghbi, W. A., Chambers, J. B., Dumesnil, J. G., Foster, E., Gottdiener, J. S., Grayburn, P. A., Khandheria, B. K., Levine, R. A., Marx, G. R., Miller, F. A., et al. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.07.013 · Cited by 1,259
2014 AHA/ACC guideline for the management of patients with valvular heart disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2014.05.014 · Cited by 989
Vongpatanasin, W., Hillis, L. D., & Lange, R. A. (1996) · New England Journal of Medicine · doi:10.1056/nejm199608083350607 · Cited by 811
Diagnosis and Management of Infective Endocarditis and Its Complications
Bayer, A. S., Bolger, A. F., Taubert, K. A., Wilson, W., Steckelberg, J., Karchmer, A. W., Levison, M., Chambers, H. F., Dajani, A. S., Gewitz, M. H., et al. (1998) · Circulation · doi:10.1161/01.cir.98.25.2936 · Cited by 759
Lancellotti, P., Pibarot, P., Chambers, J., Edvardsen, T., Delgado, V., Dulgheru, R., Pepi, M., Cosyns, B., Dweck, M. R., Garbi, M., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew025 · Cited by 567
Guidelines for the Use of Echocardiography in the Evaluation of a Cardiac Source of Embolism
Saric, M., Armour, A. C., Arnaout, M. S., Chaudhry, F. A., Grimm, R. A., Kronzon, I., Landeck, B. F., Maganti, K., Michelena, H. I., & Tolstrup, K. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2015.09.011 · Cited by 427
Fowler, V. G., Li, J., Corey, G. R., Boley, J., Marr, K. A., Gopal, A. K., Kong, L. K., Gottlieb, G., Donovan, C. L., Sexton, D. J., et al. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00250-7 · Cited by 423
“Transesophageal echocardiography (TEE) has been shown to be superior to TTE for the diagnosis of IE (18–21), especially to identify small vegetations (22), prosthetic valve endocarditis (23) and paravalvular abscesses (24).”
MethodValue and limitations of the duke criteria for the diagnosis of infective endocarditis
Habib, G., Derumeaux, G., Avierinos, J.-F., Casalta, J.-P., Jamal, F., Volot, F., Garcia, M., Lefevre, J., Biou, F., Maximovitch-Rodaminoff, A., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00116-3 · Cited by 333
“Finally, the application of DC for the diagnosis of IE has been shown to be of lower value in some patient groups, such as patients with prosthetic valves (23) and patients with IE affecting pacemaker leads (24).”
MethodUnique Features of Infective Endocarditis in Childhood
Ferrieri, P., Gewitz, M. H., Gerber, M. A., Newburger, J. W., Dajani, A. S., Shulman, S. T., Wilson, W., Bolger, A. F., Bayer, A., Levison, M. E., et al. (2002) · Circulation · doi:10.1161/01.cir.0000013073.22415.90 · Cited by 278
World Interactive Network Focused On Critical UltraSound ECHO-ICU Group, Price, S., Via, G., Sloth, E., Guarracino, F., Breitkreutz, R., Catena, E., & Talmor, D. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-49 · Cited by 255
“• TEE is mandatory in the assessment of suspected prosthetic valves IE, and in TTE positive cases to identify major valvular complications and guide surgical planning [138].”
BackgroundProsthetic Valve Endocarditis: Current Approach and Therapeutic Options
Habib, G., Thuny, F., & Avierinos, J.-F. (2008) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2007.10.007 · Cited by 194
Bioprosthetic Valve Thrombosis
Puri, R., Auffret, V., & Rodés-Cabau, J. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.02.051 · Cited by 188
Lamas, C. C., & Eykyn, S. J. (1997) · Clinical Infectious Diseases · doi:10.1086/513765 · Cited by 188
“We found that TEEs were more sensitive in detecting vegetations and abscesses in patients with NVE, as has been shown by other investigators [26-33].”
BackgroundResultJCS 2017 Guideline on Prevention and Treatment of Infective Endocarditis
Nakatani, S., Ohara, T., Ashihara, K., Izumi, C., Iwanaga, S., Eishi, K., Okita, Y., Daimon, M., Kimura, T., Toyoda, K., et al. (2019) · Circulation Journal · doi:10.1253/circj.cj-19-0549 · Cited by 179
Fagman, E., Perrotta, S., Bech-Hanssen, O., Flinck, A., Lamm, C., Olaison, L., & Svensson, G. (2012) · European Radiology · doi:10.1007/s00330-012-2491-5 · Cited by 178
“The reported sensitivity and specificity of TEE for diagnosing vegetations are 82–88 % and 97 % [7, 8], and for perivalvular abscesses 87 % and 95 % [9], as validated by findings at surgery or autopsy.”
BackgroundÖzkan, M., Kaymaz, C., Kirma, C., Sönmez, K., Özdemir, N., Balkanay, M., Yakut, C., & Deligönül, U. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00654-9 · Cited by 173
Transesophageal Echocardiography
Daniel, W. G., & Mügge, A. (1995) · New England Journal of Medicine · doi:10.1056/nejm199505113321906 · Cited by 178
Self-citationUnique Features of Infective Endocarditis in Childhood
Ferrieri, P., Gewitz, M. H., Gerber, M. A., Newburger, J. W., Dajani, A. S., Shulman, S. T., Wilson, W., Bolger, A. F., Bayer, A. S., Levison, M. E., et al. (2002) · PEDIATRICS · doi:10.1542/peds.109.5.931 · Cited by 158
Transesophageal echocardiography in critically ill patients*
Colreavy, F. B., Donovan, K. D., Lee, K. Y., & Weekes, J. N. (2002) · Critical Care Medicine · doi:10.1097/00003246-200205000-00007 · Cited by 142
Lindner, J. R., Case, R. A., Dent, J. M., Abbott, R. D., Scheld, W. M., & Kaul, S. (1996) · Circulation · doi:10.1161/01.cir.93.4.730 · Cited by 127
Montorsi, P., Bernardi, F., Muratori, M., Cavoretto, D., & Pepi, M. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00607-4 · Cited by 125
Endocarditis-Associated Paravalvular Abscesses
Blumberg, E. A., Karalis, D. A., Chandrasekaran, K., Wahl, J. M., Vilaro, J., Covalesky, V. A., & Mintz, G. S. (1995) · Chest · doi:10.1378/chest.107.4.898 · Cited by 114
Habets, J., Tanis, W., Reitsma, J. B., van den Brink, R. B. A., Mali, W. P. T. M., Chamuleau, S. A. J., & Budde, R. P. J. (2015) · European Radiology · doi:10.1007/s00330-015-3605-7 · Cited by 110
“Two studies had a long time interval (>2 weeks) between index test and reference standard [14, 22].”
BackgroundMelgar, G. R., Nasser, R. M., Gordon, S. M., Lytle, B. W., Keys, T. F., & Longworth, D. L. (1997) · Medicine · doi:10.1097/00005792-199703000-00002 · Cited by 106
Best Practices for Imaging Cardiac Device–Related Infections and Endocarditis
Dilsizian, V., Budde, R. P. J., Chen, W., Mankad, S. V., Lindner, J. R., & Nieman, K. (2021) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2021.09.029 · Cited by 111
2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Cuartas, M. M., Abreu, A., Adamo, M., Marsan, N. A., Barili, F., Bonaros, N. E., Cosyns, B., et al. (2025) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezaf276 · Cited by 108
Truninger, K., Jost, C. H. A., Seifert, B., Vogt, P. R., Follath, F., Schaffner, A., & Jenni, R. (1999) · Heart · doi:10.1136/hrt.82.6.714 · Cited by 100
Galar, A., Weil, A. A., Dudzinski, D. M., Muñóz, P., & Siedner, M. J. (2019) · Clinical Microbiology Reviews · doi:10.1128/cmr.00041-18 · Cited by 103
“TEE is considered the method of choice for diagnosis of PVE (97), because although transthoracic echocardiography (TTE) may lead to a diagnosis in some cases, TEE has a higher sensitivity for PVE (98, 99) (Fig.”
MethodHabets, J., Tanis, W., van Herwerden, L. A., van den Brink, R. B. A., Mali, W. P. T. M., de Mol, B. A. J. M., Chamuleau, S. A. J., & Budde, R. P. J. (2013) · International journal of cardiac imaging · doi:10.1007/s10554-013-0335-2 · Cited by 99
Tingleff, J., Egeblad, H., Gøtzsche, C.-O., Baandrup, U. T., Kristensen, B. Ø., Pilegaard, H. K., & Pettersson, G. (1995) · American Heart Journal · doi:10.1016/0002-8703(95)90241-4 · Cited by 95
Nosocomial endocarditis in the intensive care unit: An analysis of 22 cases
Gouëllo, J. P., Asfar, P., Brenet, O., Kouatchet, A., Berthelot, G., & Alquier, P. (2000) · Critical Care Medicine · doi:10.1097/00003246-200002000-00015 · Cited by 98
“The transesophageal view is much more sensitive than transthoracic echocardiography, especially for detecting small vegetations (22), prosthetic valve endocarditis (23), and paravalvular abscesses (24).”
BackgroundAlexis, S. L., Malik, A. H., George, I., Hahn, R. T., Khalique, O. K., Seetharam, K., Bhatt, D. L., & Tang, G. H. L. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.120.017347 · Cited by 96
Infections of intracardiac devices
Karchmer, A. W., & Longworth, D. L. (2002) · Infectious Disease Clinics of North America · doi:10.1016/s0891-5520(01)00005-8 · Cited by 91
“[36,45,46].”
BackgroundProsthetic valve endocarditis – A trouble or a challenge?
Ivanović, B., Trifunović, D., Matic, S., Petrović, J., Šačić, D., & Tadić, M. (2018) · Journal of Cardiology · doi:10.1016/j.jjcc.2018.08.007 · Cited by 91
Diagnostic evaluation of left-sided prosthetic heart valve dysfunction
Habets, J., Budde, R. P. J., Symersky, P., van den Brink, R. B. A., de Mol, B. A. J. M., Mali, W. P. T. M., van Herwerden, L. A., & Chamuleau, S. A. J. (2011) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.71 · Cited by 81
“TEE is superior to TTE for establishing the pathological causes of PHV obstruction in both the aortic and mitral position ( Figure 1 )”
Method18F-FDG positron emission tomography/computed tomography in infective endocarditis
Salomäki, S. P., Saraste, A., Kemppainen, J., Bax, J. J., Knuuti, J. M., Nuutila, P., Seppänen, M., Roivainen, A., Airaksinen, J. K. E., Pirilä, L., et al. (2015) · Journal of Nuclear Cardiology · doi:10.1007/s12350-015-0325-y · Cited by 80
Koo, H. J., Yang, D. H., Kang, J., Lee, J. Y., Kim, D., Song, J., Kang, D., Song, J., Kim, J. B., Jung, S., et al. (2017) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jex010 · Cited by 81
Smallhorn, J. F., Humpl, T., & McCrindle, B. W. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00419-4 · Cited by 78
Hansalia, S., Biswas, M., Dutta, R., Hage, F. G., Hsiung, M. C., Nanda, N. C., Singh, P., Manda, J., Kesanolla, S. K., Wei, J., et al. (2009) · Echocardiography · doi:10.1111/j.1540-8175.2009.01042.x · Cited by 67
Role of echocardiography in the diagnosis and management of infective endocarditis
Jacob, S., & Tong, A. T. (2002) · Current Opinion in Cardiology · doi:10.1097/00001573-200209000-00006 · Cited by 68
“Taams et al. (1990) [19] 12 83 33 Alton et al. (1992) [25] 6 100 17 Daniel et al. (1993) [14] 33 82 36 Zabalgoitia et al. (1993) [24] (bioprosthesis) 44 86 44 TEE, transesophageal echocardiography; TTE, transthoracic echocardiography. is cerebrovascular [30–32].”
Swedish guidelines for diagnosis and treatment of infective endocarditis
Westling, K., Aufwerber, E., Ekdahl, C., Friman, G., Gårdlund, B., Julander, I., Olaison, L., Olesund, C., Rundström, H., Snygg‐Martin, U., et al. (2007) · Scandinavian Journal of Infectious Diseases · doi:10.1080/00365540701534517 · Cited by 66
“In PVE, TEE is clearly superior than TTE, with a sensitivity 88% vs 57%, respectively, in the diagnosis of vegetations [27] and provides improved diagnosis of intracardiac abscesses that are more frequent in PVE [28].”
BackgroundInfections Associated with Long-Term Prosthetic Devices
Sampedro, M. F., & Patel, R. (2007) · Infectious Disease Clinics of North America · doi:10.1016/j.idc.2007.07.001 · Cited by 65
Infections of intracardiac devices
Karchmer, A. W., & Longworth, D. L. (2003) · Cardiology Clinics · doi:10.1016/s0733-8651(03)00032-8 · Cited by 66
Imaging techniques for diagnosis of infective endocarditis
Sachdev, M., Peterson, G., & Jollis, J. G. (2002) · Infectious Disease Clinics of North America · doi:10.1016/s0891-5520(02)00003-x · Cited by 71
“Investigators have reported sensitivities ranging from 48% to 100% for TEE compared with 18% to 63% for TTE [10–17].”
MethodSchulz, R., Werner, G. S., Fuchs, J. B., Andreas, S., Prange, H., Ruschewski, W., & Kreuzer, H. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014846 · Cited by 64
Prosthetic Mitral Valve Thrombosis: Can Fluoroscopy Predict the Efficacy of Thrombolytic Treatment?
Montorsi, P., Cavoretto, D., Alimento, M., Muratori, M., & Pepi, M. (2003) · Circulation · doi:10.1161/01.cir.0000087900.45365.45 · Cited by 62
Long-term prognosis of early and late prosthetic valve endocarditis
Castillo, J. C., Anguita, M. P., Torres, F., Mesa, D., Franco, M., González, E., Muñoz, Í., & Vallés, F. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.01.056 · Cited by 63
ECHOCARDIOGRAPHIC DETECTION OF CARDIAC VALVE VEGETATIONS AND PROGNOSTIC IMPLICATIONS
Mügge, A. (1993) · Infectious Disease Clinics of North America · doi:10.1016/s0891-5520(20)30564-x · Cited by 63
Self-citationOliver, J. M., Gallego, P., Gonzalez, A. E., DOMINGUEZ, F., Gamallo, C., & Mesa, J. M. (1996) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(96)90066-8 · Cited by 57
Doppler echocardiographic evaluation of prosthetic valve function
Pîbarot, P., & Dumesnil, J. G. (2011) · Heart · doi:10.1136/heartjnl-2011-300351 · Cited by 56
Treatment options for coarctation of the aorta
Gibbs, J. L. (2000) · Heart · doi:10.1136/heart.84.1.11 · Cited by 55
Short-course thrombolysis as the first line of therapy for cardiac valve thrombosis
Manteiga, R., Souto, J. C., Altés, A., Mateo, J., Arís, A., Domínguez, J. M., Borràs, X., Carreras, F., & Fontcuberta, J. (1998) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(98)70355-1 · Cited by 51
Tuberculosis Transmitted Through Transplantation
Graham, J., Kearns, A., Magee, J. G., El-Sheikh, M. F. A., Hudson, M., Manas, D. M., Gould, F. K., Orr, K. E., & Freeman, R. J. (2001) · Journal of Infection · doi:10.1053/jinf.2000.0879 · Cited by 50
Casella, F., Rana, B. S., Casazza, G., Bhan, A., Kapetanakis, S., Omigie, J., Reiken, J., & Monaghan, M. J. (2009) · Echocardiography · doi:10.1111/j.1540-8175.2009.00906.x · Cited by 49
Role of echocardiography in patients with stroke
Nakanishi, K., & Homma, S. (2016) · Journal of Cardiology · doi:10.1016/j.jjcc.2016.05.001 · Cited by 51
“[44,45].”
Endocarditis and associated complications
Lester, S. J., & Wilansky, S. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000270275.89478.5f · Cited by 44
“In the setting of prosthetic-valve endocarditis, the sensitivity of TTE is generally reported to be below 50% while that of TEE remains between 82% and 90% (15, 19, 20).”
BackgroundInfective endocarditis: diagnosis and management
Haldar, S. M., & O’Gara, P. T. (2006) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio0535 · Cited by 42
“TTE does not provide adequate visualization of prosthetic heart valves, especially in the mitral position, because of acoustic shadowing, which can reduce diagnostic sensitivity to 15–35%”
BackgroundTransesophageal Echocardiographic (TEE) Evaluation of Prosthetic Valves
Bach, D. S. (2000) · Cardiology Clinics · doi:10.1016/s0733-8651(05)70178-8 · Cited by 42
Imaging techniques for diagnosis of infective endocarditis
Sachdev, M., Peterson, G., & Jollis, J. G. (2003) · Cardiology Clinics · doi:10.1016/s0733-8651(03)00026-2 · Cited by 41
Anwar, A. M., Nosir, Y. F. M., Alasnag, M. A., & Chamsi‐Pasha, H. (2013) · Echocardiography · doi:10.1111/echo.12327 · Cited by 41
“Transesophageal echocardiography (TEE) has the ability to integrate structural information and hemodynamic function that help in better identification of PV type, assessment of its function, and diagnosing dysfunction.(2) However, the evaluation of PV remains a problem due to poor acoustic properties of mechanical val…”
BackgroundThe impact of transesophageal echocardiography on daily clinical practice
Kühl, H. P., & Hanrath, P. (2004) · European Journal of Echocardiography · doi:10.1016/j.euje.2004.04.007 · Cited by 41
Casabé, J. H., Deschle, H., Cortés, C. M., Stutzbach, P. G., Hershson, A., Nagel, C., Guevara, E., Torino, A., Raffaelli, H., Favaloro, R. R., et al. (2003) · Revista Española de Cardiología · doi:10.1016/s0300-8932(03)76919-x · Cited by 42
Tak, T., Reed, K. D., Haselby, R. C., McCauley, C. S., & Shukla, S. K. (2002) · PubMed · Cited by 40
Jander, N., Kienzle, R.-P., Kayser, G., Neumann, F., Gohlke-Baerwolf, C., & Minners, J. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2011.08.038 · Cited by 37
Infective Endocarditis in the Elderly: Diagnostic and Treatment Options
Ursi, M. P., Durante‐Mangoni, E., Rajani, R., Hancock, J., Chambers, J. B., & Prendergast, B. (2018) · Drugs & Aging · doi:10.1007/s40266-018-0614-7 · Cited by 37
Prosthetic valve endocarditis: state of the heart
Nagpal, A., Sohail, M. R., & Steckelberg, J. M. (2012) · Clinical Investigation · doi:10.4155/cli.12.70 · Cited by 31
Prosthetic heart valves: Types and echocardiographic evaluation
Aslam, A. K., Aslam, A. F., Vasavada, B. C., & Khan, I. A. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2006.12.037 · Cited by 33
“In another study [81], compared with transthoracic, transesophageal echocardiography had a higher sensitivity and specificity for detecting morphological abnormalities in prosthetic valves in”
BackgroundMethodResultInfluentialTransesophageal Echocardiography (TEE) in the Evaluation of Infective Endocarditis
Ryan, E. W., & Bolger, A. F. (2000) · Cardiology Clinics · doi:10.1016/s0733-8651(05)70179-x · Cited by 32
Presti, S. L., Elajami, T. K., Zmaili, M. A., Reyaldeen, R. M., & Xu, B. (2021) · World Journal of Cardiology · doi:10.4330/wjc.v13.i8.254 · Cited by 36
Olut, A. I., & Erkek, E. (2005) · Scandinavian Journal of Infectious Diseases · doi:10.1080/00365540500262567 · Cited by 31
“Previous studies have demonstrated that sensitivity of echocardiography in diagnosing PVE is markedly enhanced by the TEE technique, and sensitivities of TEE and TTE have been reported as 82 /96% and 17 /36%, respectively [13,14].”
BackgroundEVALUATION OF PROSTHETIC VALVE FUNCTION AND ASSOCIATED COMPLICATIONS
Barbetseas, J. D., & Zoghbi, W. A. (1998) · Cardiology Clinics · doi:10.1016/s0733-8651(05)70029-1 · Cited by 31
Faletra, F. F., Constantin, C., Chiara, F. D., Masciocco, G., Santambrogio, G. M., Moreo, A. M., Alberti, A., Vitali, E., & Pellegrini, A. (2000) · The American Journal of Medicine · doi:10.1016/s0002-9343(00)00344-2 · Cited by 29
Infections of Prosthetic Heart Valves
Karchmer, A. W. (2014) · ASM Press eBooks · doi:10.1128/9781555818067.ch8 · Cited by 29
Are all echocardiographic findings equally predictive for diagnosis in prosthetic endocarditis?
Ronderos, R., Portis, M., Stoermann, W., & Sarmiento, C. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.03.024 · Cited by 27
Wilson, W. R. (1998) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.1998.tb00863.x · Cited by 31
Bourque, J. M., Birgersdotter-Green, U. M., Bravo, P. E., Budde, R. P. J., Chen, W., Chu, V. H. Y., Dilsizian, V., Erba, P. A., Kattan, C. M. G., Habib, G., et al. (2024) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2024.01.004 · Cited by 26
Evaluation of the Mitral and Aortic Valves With Cardiac CT Angiography
Chheda, S., Srichai, M. B., Donnino, R. M., Kim, D. C., Lim, R., & Jacobs, J. E. (2010) · Journal of Thoracic Imaging · doi:10.1097/rti.0b013e31819d12b1 · Cited by 25
“A potential limitation of echocardiographic assessment of prosthetic valves is the presence of acoustic shadowing, which can impair accurate visualization of the valve prosthesis and associated pathology, including vegetations, paravalvular abscesses, and thrombi.(22) CTA usually enables assessment of prosthetic valve…”
BackgroundBourque, J. M., Birgersdotter-Green, U. M., Bravo, P. E., Budde, R. P. J., Chen, W., Chu, V. H. Y., Dilsizian, V., Erba, P. A., Kattan, C. M. G., Habib, G., et al. (2024) · Clinical Infectious Diseases · doi:10.1093/cid/ciae046 · Cited by 30
Diagnosing prosthetic mitral valve thrombosis and the effect of the type of prosthesis
Montorsi, P., Cavoretto, D., Parolari, A., Muratori, M., Alimento, M., & Pepi, M. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02394-9 · Cited by 23
THE ROLE OF INTRAOPERATIVE ECHOCARDIOGRAPHY IN VALVE SURGERY
Grimm, R. A., & Stewart, W. J. (1998) · Cardiology Clinics · doi:10.1016/s0733-8651(05)70027-8 · Cited by 23
Early Biological Valve Failure: Structural Valve Degeneration, Thrombosis, or Endocarditis?
Fazzari, F., Baggiano, A., Fusini, L., Alì, S. G., Gripari, P., Junod, D., Mancini, M. E., Maragna, R., Mushtaq, S., Pontone, G., et al. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12175740 · Cited by 24
“In the case of clinical suspicion of IE, blood cultures are mandatory, as well as TEE, given the low sensitivity of TTE (17–36%) in this context [32,52].”
BackgroundBourque, J. M., Birgersdotter-Green, U. M., Bravo, P. E., Budde, R. P. J., Chen, W., Chu, V. H. Y., Dilsizian, V., Erba, P. A., Kattan, C. M. G., Habib, G., et al. (2024) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2023.101786 · Cited by 22
Almirante, B., & Miró, J. M. (2008) · Enfermedades Infecciosas y Microbiología Clínica · doi:10.1016/s0213-005x(08)75281-9 · Cited by 29
Brugada syndrome: an electrocardiographic diagnosis not to be missed
Brugada, P. (2000) · Heart · doi:10.1136/heart.84.1.1 · Cited by 23
Evaluation of Fever and Infections in Cardiac Surgery Patients
Rhee, C., & Sax, P. E. (2014) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/1089253214538524 · Cited by 21
Echocardiography in the sepsis syndromes
Via, G., Price, S., & Storti, E. (2011) · The Ultrasound Journal · doi:10.1007/s13089-011-0069-0 · Cited by 23
Krivokapich, J., & CHILD, J. S. (1996) · Cardiology Clinics · doi:10.1016/s0733-8651(05)70290-3 · Cited by 20
Interleukin 6: a message from the heart
HERITY, N. A. (2000) · Heart · doi:10.1136/heart.84.1.9 · Cited by 19
Individual value of each of the Duke criteria for the diagnosis of infective endocarditis
Rognon, R., Kehtari, R., & Francioli, P. B. (1999) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.1999.tb00163.x · Cited by 20
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Cited by 23
Saksena, D. S., Mishra, Y. K., Muralidharan, S., Kanhere, V. M., Srivastava, P. K., & Srivastava, C. P. (2019) · Indian Journal of Thoracic and Cardiovascular Surgery · doi:10.1007/s12055-019-00789-z · Cited by 21
Overview of Transesophageal Echocardiography for the Chest Physician
Milani, R. V., Lavie, C. J., Gilliland, Y. E., Cassidy, M. M., & Bernal, J. A. (2003) · CHEST Journal · doi:10.1378/chest.124.3.1081 · Cited by 17
Miguel Oyonarte, G., Rodrigo Montagna, M., Braun, S. L., Rojo, P., Jara, J. L., Cereceda, M., Morales, M., Nazal, C. N., & Alonso, F. T. (2012) · Revista médica de Chile · doi:10.4067/s0034-98872012001200001 · Cited by 31
Zamorano, J. L., Sanz, J., Moreno, R., Almería, C., Rodrigo, J. L., de Marco, E., Serra, V., Samedi, M., & Sánchez‐Harguindey, L. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.118927 · Cited by 18
Metadata
- Authors
- Daniel, W. G., Mügge, A., Grote, J., Hausmann, D., Nikutta, P., Laas, J., Lichtlen, P. R., & Martin, R. P.
- Affiliations
- Emory University (US)
- Corresponding author
- Daniel, Werner G.
- Venue
- The American Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 1993-01
- Volume
- 71
- Issue
- 2
- Pages
- 210-215
- ISSN
- 0002-9149 (ISSN-L)
- OpenAlex
- W2121874306
- Cited by
- 306
- References
- 29
- Citations by year
- 2026: 4 · 2025: 11 · 2024: 10 · 2023: 5 · 2022: 4 · 2021: 6 · 2020: 6 · 2019: 6 · 2018: 7 · 2017: 4 · 2016: 16 · 2015: 5 · 2014: 9 · 2013: 8 · 2012: 7
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The American Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Congenital Heart Disease Studies
- Keywords
- transthoracic echocardiography, transesophageal echocardiography, bioprosthetic heart valves, mechanical heart valves, prosthetic valve endocarditis, prosthetic valve thrombosis, prosthetic valve degeneration, mitral valve prosthesis, aortic valve prosthesis, sensitivity and specificity, acoustic shadowing
- MeSH terms
- Aortic Valve, Bioprosthesis, Echocardiography, Endocarditis, Female, Heart Valve Prosthesis, Humans, Male, Middle Aged, Mitral Valve, Reoperation, Sensitivity and Specificity, Thrombosis, Prosthesis-Related Infections
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.