Comparison of transthoracic and transesophageal echocardiography for detection of abnormalities of prosthetic and bioprosthetic valves in the mitral and aortic positions
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Two-dimensional echocardiography is the diagnostic procedure of choice for evaluation of prosthetic valve abnormalities. However, transthoracic echocardiography (TTE) may be limited owing to acoustic shadowing and poor acoustic windows. Some of these limitations may be overcome by transesophageal echocardiography (TEE). One hundred twenty-six patients with 148 prosthetic valves (113 bioprostheses and 35 mechanical devices) were studied by M-mode and 2-dimensional TTE and TEE. Prosthetic valve morphology was confirmed by surgery or autopsy in all cases; 124 prostheses were classified as diseased (33 endocarditis, 8 thrombi, and 83 degeneration defined as leaflet thickening > 3 mm with restricted motion) and 24 as normal. Prosthetic valve endocarditis and thrombi were correctly identified by TTE in 12 of 33 (36%) and 1 of 8 (13%) prostheses, respectively, but could be diagnosed by TEE in 27 of 33 (82%; p < 0.001) and 8 of 8 (100%; p < 0.01), respectively. Compared with TTE, TEE had a higher sensitivity for morphologic prosthetic valve abnormalities in patients with either bioprostheses (88 [87%] vs 66 [65%] of 101 prostheses; p < 0.01) or mechanical devices (19 [83%] vs 5 [22%] of 23 prostheses; p < 0.01) and in patients with a prosthesis in either the aortic (49 [77%] vs 32 [50%] of 64; p < 0.01) or mitral (58 [97%] vs 39 [65%] of 60; p < 0.001) position. Overall, sensitivity and specificity were 57 and 63%, respectively, for TTE, and 86 and 88%, respectively, for TEE.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the setting of a prosthetic valve, transthoracic images are greatly hampered by the structural components of the prosthesis and are inadequate for assessment of the perivalvular area where those infections often start.48”
Citations
Cites
Safety of transesophageal echocardiography. A multicenter survey of 10,419 examinations.
Daniel, W. G., Erbel, R., Kasper, W., Visser, C. A., Engberding, R., Sutherland, G. R., Grube, E., Hanrath, P., Maisch, B., & Dennig, K. (1991) · Circulation · doi:10.1161/01.cir.83.3.817 · Cited by 825
Self-citationSEWARD, J. B., KHANDHERIA, B. K., OH, J. K., ABEL, M. D., HUGHES, R. W., EDWARDS, W. D., NICHOLS, B. A., FREEMAN, W. K., & TAJIK, A. J. (1988) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)65529-3 · Cited by 791
Daniel, W. G., Mügge, A., Martin, R. P., Lindert, O., Hausmann, D., Nonnast-Daniel, B., Laas, J., & Lichtlen, P. R. (1991) · New England Journal of Medicine · doi:10.1056/nejm199103213241203 · Cited by 723
Self-citationMügge, A., Daniel, W. G., Frank, G., & Lichtlen, P. R. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90104-6 · Cited by 654
Self-citationFrazin, L., Talano, J. V., Stephanides, L., Loeb, H. S., Kopel, L., & Gunnar, R. M. (1976) · Circulation · doi:10.1161/01.cir.54.1.102 · Cited by 300
Schluter, M., Langenstein, B. A., Polster, J., Kremer, P., Souquet, J., Engel, S., & Hanrath, P. (1982) · Heart · doi:10.1136/hrt.48.1.67 · Cited by 168
Normal and abnormal prosthetic valve function as assessed by doppler echocardiography
Panidis, I. P., Ross, J., & Mintz, G. S. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80046-8 · Cited by 165
Nellessen, U., Schnittger, I., Appleton, C. P., Masuyama, T., Bolger, A., Fischell, T. A., Tye, T., & Popp, R. L. (1988) · Circulation · doi:10.1161/01.cir.78.4.848 · Cited by 165
Value and limitations of transesophageal echocardiography in assessment of mitral valve prostheses.
Khandheria, B. K., Seward, J. B., Oh, J. K., Freeman, W. K., Nichols, B. A., Sinak, L. J., Miller, F. A., & Tajik, A. J. (1991) · Circulation · doi:10.1161/01.cir.83.6.1956 · Cited by 141
Doppler echocardiographic evaluation of Hancock and Björk-Shiley prosthetic valves
Sagar, K. B., Wann, L. S., Paulsen, W., & Romhilt, D. W. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80480-6 · Cited by 119
Cited by
Items 101–200 of 309
Conservative Treatment of Prosthetic Valve Endocarditis due to Mycobacterium fortuitum
Kunin, M., Salamon, F., Weinberger, M., Genkin, I., Sagie, A., & Tur‐Kaspa, R. (2002) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-002-0763-8 · Cited by 16
Update on Echocardiography in the Management of Infective Endocarditis
Sedgwick, J., & Burstow, D. J. (2012) · Current Infectious Disease Reports · doi:10.1007/s11908-012-0262-8 · Cited by 15
The pivotal role of echocardiography in cardiac sources of embolism
Rana, B. S., Monaghan, M. J., Ring, L. S., Shapiro, L. M., & Nihoyannopoulos, P. (2011) · European Journal of Echocardiography · doi:10.1093/ejechocard/jer122 · Cited by 20
“TEE has high sensitivity (86–94%) and specificity (88–100%) for the detection of vegetations.(21,22) Differential diagnosis includes thrombus, sutures, or pledgets.”
BackgroundEvaluation of hypoxemic patients with transesophageal echocardiography
Hoole, S. P., & Falter, F. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000270281.49924.aa · Cited by 15
“By casting the shadow toward the left ventricle, it enables the left atrium to be examined in detail for thrombus (11, 12) and enables a detailed assessment of regurgitation into the left atrium.”
MethodManagement of Prosthetic Heart Valve Complications
Mankad, S. V. (2012) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-012-0212-7 · Cited by 15
Diagnosis of Left-Sided Mechanical Prosthetic Valve Thrombosis: A Pictorial Review
Șerban, A. M., Dădârlat‐Pop, A., Achim, A., Gavan, D. E., Pepine, D., Rancea, R., & Tomoaia, R. (2023) · Journal of Personalized Medicine · doi:10.3390/jpm13060967 · Cited by 14
“A better resolution of the mitral prosthesis should be improved by aligning the ultrasound beam parallel to the opening movement of the occluder [10,11].”
BackgroundAnticoagulation Management in Patients with Valve Replacement.
Saksena, D. S., Muralidharan, S., Mishra, Y. K., Kanhere, V. M., Mohanty, B. B., Srivastava, C. P., Mange, J., Puranik, M., Nair, M. P., Goel, P., et al. (2018) · PubMed · Cited by 18
Transoesophageal Echo-Doppler in cardiology
Hanrath, P. (2001) · Heart · doi:10.1136/heart.86.5.586 · Cited by 17
Role of transoesophageal echocardiography in infective endocarditis
Flachskampf, F. A., & DANIEL, W. G. (2000) · Heart · doi:10.1136/heart.84.1.3 · Cited by 14
Self-citationBourque, J. M., Birgersdotter-Green, U. M., Bravo, P. E., Budde, R. P. J., Chen, W., Chu, V. H. Y., Dilsizian, V., Erba, P. A., Kattan, C. M. G., Habib, G., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.01.043 · Cited by 15
Appropriate use of echocardiography in managingStaphylococcus aureusbacteremia
Palraj, R., & Sohail, M. R. (2012) · Expert Review of Anti-infective Therapy · doi:10.1586/eri.12.22 · Cited by 14
Clinical Guideline for the Diagnosis and Treatment of Cardiovascular Infections
The Korean Society of Infectious Diseases, Korean Society for Chemotherapy, The Korean Society of Cardiology, & The Korean Society for Thoracic and Cardiovascular Surgery (2011) · Infection and Chemotherapy · doi:10.3947/ic.2011.43.2.129 · Cited by 13
Cicioni, C., Luzio, V. D., Emidio, L. D., Remigis, F. D., Fragassi, G., Gregorini, R., Mazzola, A., Paparoni, S., Prosperi, F., & Ferri, C. (2006) · Journal of Cardiovascular Medicine · doi:10.2459/01.jcm.0000242998.74923.4d · Cited by 14
Mauri, L., de Lemos, J. A., & O’Gara, P. T. (2001) · Current Problems in Cardiology · doi:10.1053/cd.2001.v26.a118054 · Cited by 14
VentricularPatch Endocarditis Caused by Propionibacteriumacnes: Advantages of Gallium Scanning
Vandenbos, F., Roger, P., Mondain-Miton, V., Dunais, B., Fouche, R., Kreitmann, P., Carles, D., Migneco, O., & Dellamonica, P. (2001) · Journal of Infection · doi:10.1053/jinf.2001.0905 · Cited by 13
Blackwood, R. (1996) · Routledge eBooks · doi:10.4324/9781843143383-37 · Cited by 13
JSMM Clinical Practice Guidelines for Diagnosis and Treatment of Invasive Candidiasis
(2013) · Medical Mycology Journal · doi:10.3314/mmj.54.147 · Cited by 12
Caring for patients with prosthetic heart valves.
Bettadapur, M. S., Griffin, B. P., & Asher, C. R. (2002) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.69.1.75 · Cited by 12
Propionibacterium acnes Endocarditis of a Prosthetic Aortic Valve
List, R. J., Sheikh, N., Theologou, T., Mitchell, I. M., & Mathew, T. (2009) · Clinical Cardiology · doi:10.1002/clc.20492 · Cited by 12
Endocardites à : étude rétrospective de 12 patients
Abgueguen, P., Gouëllo, J. P., Pichard, É., Chabasse, D., Donal, E., & Alquier, P. (2002) · La Revue de Médecine Interne · doi:10.1016/s0248-8663(01)00512-4 · Cited by 14
Fair comparison of mortality data following cardiac surgery
Écochard, R., GEVIGNEY, G. D., & Colin, C. (2000) · Heart · doi:10.1136/heart.84.1.5 · Cited by 12
TRANSESOPHAGEAL ECHOCARDIOGRAPHY
Porembka, D. T. (1996) · Critical Care Clinics · doi:10.1016/s0749-0704(05)70284-0 · Cited by 13
Propionibacterium acnes: A rare cause of late prosthetic valve endocarditis and aortic root abscess
Kanjanauthai, S., & Kanluen, T. (2008) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.11.062 · Cited by 11
“In our case, if an anaerobic blood culture was performed, we would have detected P. acnes bacteremia and determined a correct diagnosis of PVE secondary to P. acnes instead of culture negative endocarditis initially.”
MethodInfluentialKupferwasser, I., Mohr-Kahaly, S., Erbel, R. M., Nolting, A., Dohmen, G., Oelert, H., & Meyer, J. (1997) · Echocardiography · doi:10.1111/j.1540-8175.1997.tb00736.x · Cited by 11
ASSESSMENT OF ENDOCARDITIS AND ASSOCIATED COMPLICATIONS WITH TRANSESOPHAGEAL ECHOCARDIOGRAPHY
Shanewise, J. S., & Martin, R. P. (1996) · Critical Care Clinics · doi:10.1016/s0749-0704(05)70253-0 · Cited by 11
Self-citationLiu, F., Ge, J., Kupferwasser, I., Meyer, J., Mohr-Kahaly, S., Rohmann, S., & Erbel, R. M. (1995) · Echocardiography · doi:10.1111/j.1540-8175.1995.tb00857.x · Cited by 12
Tsutsumi, T., & Eron, L. J. (2012) · Infectious Diseases in Clinical Practice · doi:10.1097/ipc.0b013e318261143a · Cited by 10
ECG-Gated MDCT After Aortic and Mitral Valve Surgery
Ghersin, E., Martinez, C. A., Singh, V., Fishman, J. E., Macon, C. J., Therrien, J. E. R., & Litmanovich, D. E. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.13.12404 · Cited by 10
“However, TTE has inherent limitations in the evaluation of valvular abnormalities, including interobserver variability, poor acoustic windows due to body habitus or chronic obstructive pulmonary disease, and the possibility of acoustic shadows, which impede visualization of prosthetic valves [1, 2].”
BackgroundInfections associated with implanted medical devices
Millar, M. R., & Wareham, D. W. (2010) · Elsevier eBooks · doi:10.1016/b978-0-7020-4064-1.00042-7 · Cited by 11
(2016) · Elsevier eBooks · doi:10.1016/b978-0-323-26011-4.09957-5 · Cited by 9
Metz, E., Hartmann, M., von Birgelen, C., Haalebos, M. M. P., & Verhorst, P. M. J. (2006) · International journal of cardiac imaging · doi:10.1007/s10554-006-9106-7 · Cited by 10
“usually associated with significant diastolic leakage [2–5, 8, 9, 13].”
BackgroundInfective endocarditis: a review of the best treatment options
Calza, L., Manfredi, R., & Chiodo, F. (2004) · Expert Opinion on Pharmacotherapy · doi:10.1517/14656566.5.9.1899 · Cited by 12
“The overall sensitivity for detecting valvular vegetations ranges 75 – 95% for transoesophageal echocardiography, with a specificity of 85 – 98% [32,33].”
BackgroundMykén, P. S. U., Berggren, H., Larsson, S., Roberts, B., Wallentin, I., & Caidahl, K. (1998) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(98)70166-7 · Cited by 9
A case of trichosporon beigelii endocarditis 8 years after aortic valve replacement
Sidarous, M. G., O'Reilly, M. V., & Cherubim, C. E. (1994) · Clinical Cardiology · doi:10.1002/clc.4960170413 · Cited by 9
2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Cuartas, M. M., Abreu, A., Adamo, M., Marsan, N. A., Barili, F., Bonaros, N. E., Cosyns, B., et al. (2025) · European Heart Journal - Valvular and Structural Heart Disease · doi:10.1093/ehjvshd/xwag001 · Cited by 73
Stuck leaflet of bileaflet prosthesis in mitral position - five cases to make us think
Almeida, J., Santos, A. C., Barreiros, F., García, M., & Pinho, P. (2007) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1510/icvts.2006.145193 · Cited by 8
Mitral Prosthetic Valve Assessment by Echocardiographic Guidelines
Hahn, R. T. (2013) · Cardiology Clinics · doi:10.1016/j.ccl.2013.03.004 · Cited by 10
Vogt, M. O., & Kühn, A. (2016) · Wiley eBooks · doi:10.1002/9781118742440.ch40 · Cited by 8
Daniel, W. G., & Flachskampf, F. A. (2009) · doi:10.1093/med/9780199566990.003.022 · Cited by 8
Self-citationChoi, J. Y., & Kim, K. S. (2008) · Journal of Cardiovascular Ultrasound · doi:10.4250/jcu.2008.16.3.84 · Cited by 7
Guerrero, M. L. F., Alonso, J. M., Rey, M., Martinell, J., Górgolas, M., Artiz, V., & Fraile, J. (2009) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2009.06.019 · Cited by 7
Burkule, N. J., Govind, S. C., Sola, S., & Bansal, M. (2018) · Journal of The Indian Academy of Echocardiography & Cardiovascular Imaging · doi:10.4103/jiae.jiae_7_18 · Cited by 7
Safety and clinical benefits of transsubxiphoidal left ventricular puncture
Zuguchi, M., Shindoh, C., Chida, K., Saito, H., Takai, Y., Yamada, S., Iguchi, A., Endo, M., Akimoto, H., & Tabayashi, K. (2001) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.10073 · Cited by 7
“Compared with mitral valve prosthesis, however, the diagnosis of aortic prosthetic valve anomalies appears to be not as accurate by either transthoracic echocardiography or transesophageal echocardiography [15].”
BackgroundUse of Echocardiography in Patients With Known or Suspected Infective Endocarditis
Lerakis, S., Lindner, J. R., & Stouffer, G. A. (1998) · The American Journal of the Medical Sciences · doi:10.1016/s0002-9629(15)40404-5 · Cited by 9
Southwestern Internal Medicine Conference: Clinical Applications of Transesophageal Echocardiography
Grayburn, P. A. (1994) · The American Journal of the Medical Sciences · doi:10.1097/00000441-199402000-00015 · Cited by 7
JCS 2026 Guideline on the Management of Infective Endocarditis
Izumi, C., Daimon, M., Kaji, S., Masumoto, A., Ashihara, K., Amano, M., Uemura, S., Ota, H., Ohara, T., Okada, K., et al. (2026) · Circulation Journal · doi:10.1253/circj.cj-25-0987 · Cited by 7
Thong, E. H., Kong, W. K. F., Poh, K. K., Wong, R. C.-C., Chai, P., & Sia, C. (2023) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd11010013 · Cited by 6
“In addition, TOE provides an unobstructed view due to the proximity of the oesophagus to the heart as well as higher-frequency transducers allowing for the visualisation of smaller masses and the better visualisation of the device’s atrial surface [230].”
BackgroundMethodResultInfluentialAdvanced Echocardiography for the Diagnosis and Management of Infective Endocarditis
Sedgwick, J., & Scalia, G. M. (2016) · InTech eBooks · doi:10.5772/64800 · Cited by 6
“Imaging with TTE is limited by the availability of an acoustic window, intervening anatomical structures between the probe and the heart, lower transducer frequency, and acoustic shadowing [36].”
BackgroundDietrich, M., Bois, M. C., Ferrufino, R. A., Cobey, F., & Mankad, R. (2020) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2020.07.052 · Cited by 6
Les actualités dans l’endocardite infectieuse
Parize, P., & Mainardi, J. (2010) · La Revue de Médecine Interne · doi:10.1016/j.revmed.2010.10.007 · Cited by 9
Mechanical Prosthetic Valve Thrombosis: Case Report and Review of the Literature
Klugherz, B. D., & Herrmann, H. C. (1998) · Journal of Thrombosis and Thrombolysis · doi:10.1023/a:1008814614213 · Cited by 6
“In a recent series of 126 patients who underwent both transthoracic and transesophageal echocardiography in the evaluation of suspected dysfunctional prostheses, transesophageal echocardiography was successful in identifying thrombus among all eight patients who subsequently had morphologically proven thrombus at reop…”
BackgroundParro, A., Cherubini, M. L. C., Amaral, C. A. F., Jacob, J. L. B., & Nicolau, J. C. (2004) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2004000400006 · Cited by 6
ZNS-Beteiligung bei akuter Endokarditis
Horstkotte, D., Piper, C., Wiemer, M., & Schultheiß, H. R. (1998) · Steinkopff eBooks · doi:10.1007/978-3-642-93694-4_5 · Cited by 9
Echocardiography in Endocarditis
Greco, C. A., Zaccaria, S., Casali, G., Nicolardi, S., & Albanese, M. (2024) · Echocardiography · doi:10.1111/echo.15945 · Cited by 5
Reversible bioprosthetic valve thrombosis from eosinophilia
Kothari, S. S., Deepti, S., & Rai, N. (2018) · BMJ Case Reports · doi:10.1136/bcr-2017-222937 · Cited by 5
Utility of transesophageal echocardiography in infective endocarditis. A review.
Jessurun, C., Mesa, A., & Wilansky, S. (1996) · Europe PMC (PubMed Central) · Cited by 8
Transesophageal echocardiography and stroke
Woods, T. D. (2005) · Current Atherosclerosis Reports · doi:10.1007/s11883-005-0016-2 · Cited by 5
“Due to the acoustic shadowing that occurs from prosthetic valves during transthoracic imaging, the yield for detection of vegetations by TEE is increased even more dramatically when applied to prosthetic heart valves [ 5 ].”
Background“Flap Valve Phenomenon” Limiting Aortic Regurgitation in Prosthetic Valve Dehiscence
Nijmeh, G., Silverman, P., & Zelinger, A. B. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.09.019 · Cited by 5
“Transesophageal echocardiography is superior to transthoracic echocardiography in diagnosing prosthetic valve endocarditis and its complications because of the image artifacts caused by the prosthesis on transthoracic examination.(1,2,4,5) Besides visualizing a vegetation or abscess, identifying a new dehiscence of a…”
BackgroundKodali, S., Vivas, Y. R., Jakub, C., Srinivasan, V., Sharma, B., Porkolab, F. L., & Traub, D. M. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.01.008 · Cited by 5
Wang, A., & Cabell, C. H. (2009) · Humana Press eBooks · doi:10.1007/978-1-59745-411-7_21 · Cited by 16
Cardiovascular Imaging: A Handbook for Clinical Practice
Bax, J. J., Kramer, C., Marwick, T., & Wijns, W. (2005) · Wiley eBooks · doi:10.1002/9781444312898 · Cited by 7
Pronóstico a corto y largo plazo de la endocarditis sobre prótesis en pacientes no drogadictos
Castillo, J. C., Sánchez, M. P. A., Moreno, A. R., Rubio, J. R. S., Calvo, F. T., Rubio, D. M., Zapata, M. F., Carvajal, I. M., Ruiz, M. C., & Belsúe, F. V. (2000) · Revista Española de Cardiología · doi:10.1016/s0300-8932(00)75140-2 · Cited by 7
“viridans 10 (23) 1 (12,5) 1 (7) 8 (38) Enterococos 3 (7) 2 (25) 1 (7) – Difteroides 4 (9) – 3 (21) 1 (5) Coxiella burnetii 5 (12) – – 5 (24) Hongos 3 (7) – 2 (14) 1 (5) Otros 3 (7) – 2 (14) 1 (5) Desconocido 5 (12) 3 (37,5) 1 (7) 1 (5)”
Relevance of cardiac imaging in the evolving landscape of infective endocarditis management
Haouzi, A. A., Khayata, M., & Xu, B. (2024) · Therapeutic Advances in Cardiovascular Disease · doi:10.1177/17539447241305587 · Cited by 4
Echocardiographic Doppler Evaluation of Prosthetic Valve Function and Dysfunction
Goldman, M. E. (2004) · KARGER eBooks · doi:10.1159/000079799 · Cited by 4
Nagaratnam, N., Nagaratnam, K., & Cheuk, G. (2017) · Springer eBooks · doi:10.1007/978-3-319-32700-6_7-1 · Cited by 4
Moreo, A. M., Lobiati, E., Chiara, B. C. D., & Mauri, F. (2007) · Heart and Vessels · doi:10.1007/s00380-007-0982-0 · Cited by 4
“Although transthoracic two-dimensional echocardiography represents the standard technique in the evaluation of tissue valve prostheses, the echogenic sewing ring and struts may limit the visualization of the leafl ets and the atrial surface of a mitral prosthetic valve.(1) An improvement in image acquisition can be ob…”
BackgroundMitral regurgitation secondary to ruptured papillary muscle
Kalra, P. R., OHRI, S. K., & MORGAN, J. M. (2000) · Heart · doi:10.1136/heart.84.1.13 · Cited by 4
Infective Endocarditis and Valvular Heart Disease
Kosowsky, J. M. (2010) · Elsevier eBooks · doi:10.1016/b978-0-323-05472-0.00081-5 · Cited by 5
“Transesophageal echocardiography (TEE), on the other hand, although more invasive and time-consuming, is far superior to TTE in its sensitivity and specificity.(17,18) Explicit criteria for the diagnosis of IE are important because underdiagnosis can lead to serious morbidity and death, whereas overdiagnosis can resul…”
BackgroundRole of echocardiography in the diagnosis and management of infective endocarditis.
Al Hashimi, H., Windy, N. A., Jc, M., Galema, T. W., ten Cate, F. J., & Simoons, M. L. (2004) · PubMed Central · Cited by 5
Mackenzie, G. S., & Heinle, S. K. (1996) · Critical Care Clinics · doi:10.1016/s0749-0704(05)70252-9 · Cited by 4
Cardiac surgical mortality: the tip of the quality assurance iceberg
Keogh, B. E. (2000) · Heart · doi:10.1136/heart.84.1.7 · Cited by 6
Additional Applications of Transesophageal Echocardiography
Wong, P. C. (2013) · Springer eBooks · doi:10.1007/978-1-84800-064-3_16 · Cited by 3
Antibiotic Therapy for Infective Endocarditis in Childhood
Calza, L., Manfredi, R., & Chiodo, F. (2006) · The Journal of Pediatric Pharmacology and Therapeutics · doi:10.5863/1551-6776-11.2.64 · Cited by 3
Obstructive Bioprosthetic Mitral Valve Thrombosis
Shetty, S. S., Malik, A. H., Aronow, W. S., Staffey, K. S., & Accaoui, R. N. E. (2020) · Future Cardiology · doi:10.2217/fca-2019-0094 · Cited by 3
Contemporary Multi-modality Imaging of Prosthetic Aortic Valves
Abadie, B. Q., & Wang, T. K. M. (2025) · Reviews in Cardiovascular Medicine · doi:10.31083/rcm25339 · Cited by 3
Hadjigeorgiou, N., Melanarkiti, D., Plakomyti, T. E., Demou, V., Giannakopoulos, V., Sapouridis, C., & Mouzarou, A. (2025) · Reviews in Cardiovascular Medicine · doi:10.31083/rcm36771 · Cited by 3
“However, in cases of PVE, the sensitivity of TTE diminishes to 36–69%, while TEE maintains a higher sensitivity, reported between 86% and 100% [51,54].”
Endocardite infecciosa: o que mudou na última década?
Salgado, Â. A., Lamas, C. D. C., & Bóia, M. N. (2013) · Revista Hospital Universitário Pedro Ernesto · doi:10.12957/rhupe.2013.7088 · Cited by 7
Fischer, C. H., Fo, O. C., Moisés, V. A., de Sousa, J. M. A., Machado, C. V., Fo, E. L., Andrade, J. L., Carvalho, A. C., & Fo, D. V. S. (1998) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x1998001200002 · Cited by 3
Vermès, E., Tardif, J., Cartier, R., Mercier, L., & Ducharme, A. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(02)74542-2 · Cited by 3
Pallasch, J., Takahashi, M., Taubert, K. A., Shulman, S. T., Burns, J. C., Falace, D. A., Newburger, J. W., Gewitz, H.-S., Tong, D., Steckelberg, J. M., et al. (2007) · Cited by 3
Jayawardena, S. R., Sooriabalan, D., Burzyantseva, O., & Sinnapunayagm, S. (2008) · Cases Journal · doi:10.1186/1757-1626-1-216 · Cited by 3
“logical abnormalities of prosthetic valves [10].”
Bakterielle Endokarditis: Die Sicht des Kardiologen
Glaser, F. H. (2003) · Journal für Kardiologie (Krause & Pachernegg GmbH) · Cited by 5
Jassal, D. S., & Picard, M. H. (2007) · Infectious disease and therapy · doi:10.3109/9781420019834.013 · Cited by 3
Thiravetyan, B., Puchongmart, C., Cruz, D., Rodriguez, C. C., & Soliman, D. (2025) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2025.09.006 · Cited by 2
Fieber und erniedrigte CD4-Zellzahl bei einem 22-jährigen Patienten aus Ghana
Ghanem, H., Hagel, S., Keller, P. M., Prochnau, D., Stallmach, A., & Pletz, M. W. (2013) · Der Internist · doi:10.1007/s00108-012-3159-6 · Cited by 2
Management of Native Valve Endocarditis
Lee, L. S., Chen, F. Y., & Cohn, L. H. (2010) · Elsevier eBooks · doi:10.1016/b978-1-4160-5225-8.00080-5 · Cited by 2
Prediction of Embolic Events in Infective Endocarditis Using Echocardiography
Iliuță, L. (2018) · InTech eBooks · doi:10.5772/intechopen.76845 · Cited by 2
Transesophageal Echocardiography
(2016) · Elsevier eBooks · doi:10.1016/b978-0-323-26011-4.09949-6 · Cited by 2
Case 9-2024: An 84-Year-Old Man with a Fall
Sargsyan, Z., Srivastava, S. D., Triant, V. A., & Ghoshhajra, B. B. (2024) · New England Journal of Medicine · doi:10.1056/nejmcpc2312731 · Cited by 2
Linee guida ESC/EACTS 2025 per il trattamento delle valvulopatie
Praz, F., Borger, M. A., Lanz, J., Cuartas, M. M., Abreu, A., Adamo, M., Marsan, N. A., Barili, F., Bonaros, N. E., Cosyns, B., et al. (2025) · Giornale Ialiano di Cardiologia · doi:10.1714/4598.46048 · Cited by 2
Dencker, M., & Roijer, A. (2008) · Scandinavian Journal of Infectious Diseases · doi:10.1080/00365540802304521 · Cited by 3
Listeria monocytogenes and Prosthetic Valve Endocarditis: Case Report and Review of the Literature
Best, R., Bhagirath, K. M., Pearce, S., & Jassal, D. S. (2016) · Infectious Diseases in Clinical Practice · doi:10.1097/ipc.0000000000000402 · Cited by 2
“First reported in 1955, approximately 80 cases of endocarditis caused by Listeria monocytogenes have been recorded worldwide to date.(1,6,7) An English-language literature review reveals 29 prior cases of prosthetic valve endocarditis caused by L.”
BackgroundResultAcute Presentations of Valvular Heart Disease
Austin, W. J., Ambrose, J., & Greenberg, B. (2010) · Elsevier eBooks · doi:10.1016/b978-1-4160-3773-6.10027-8 · Cited by 2
Anavekar, N. S., Averbach, M., & Bulwer, B. E. (2007) · Humana Press eBooks · doi:10.1007/978-1-59259-977-6_15 · Cited by 2
Endocarditis infecciosa: del diagnóstico al tratamiento
Fernandez‐Gerlinger, M., & Mainardi, J. (2016) · EMC - Tratado de Medicina · doi:10.1016/s1636-5410(16)80656-x · Cited by 5
Delgado, C., & Barturen, F. (1999) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(99)70043-x · Cited by 2
The Challenge of Assessing Heart Valve Prostheses by Doppler Echocardiography
Baumgartner, H. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.02.012 · Cited by 2
Shiran, A., Weissman, N. J., Merdler, A., Karkabi, B., Khader, N., Aviram, S., Goldstein, S. A., Pinnow, E. E., & Lewis, B. S. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)02132-4 · Cited by 2
Horstkotte, D. (1994) · Steinkopff eBooks · doi:10.1007/978-3-642-87079-8_9 · Cited by 2
Prothetischer Herzklappenersatz
Flachskampf, F. A., & Hanrath, P. (2000) · Springer eBooks · doi:10.1007/978-3-662-12156-6_78 · Cited by 2
Metadata
- Authors
- Daniel, W. G., Mügge, A., Grote, J., Hausmann, D., Nikutta, P., Laas, J., Lichtlen, P. R., & Martin, R. P.
- Affiliations
- Emory University (US)
- Corresponding author
- Daniel, Werner G.
- Venue
- The American Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 1993-01
- Volume
- 71
- Issue
- 2
- Pages
- 210-215
- ISSN
- 0002-9149 (ISSN-L)
- OpenAlex
- W2121874306
- Cited by
- 306
- References
- 29
- Citations by year
- 2026: 4 · 2025: 11 · 2024: 10 · 2023: 5 · 2022: 4 · 2021: 6 · 2020: 6 · 2019: 6 · 2018: 7 · 2017: 4 · 2016: 16 · 2015: 5 · 2014: 9 · 2013: 8 · 2012: 7
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The American Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Congenital Heart Disease Studies
- Keywords
- transthoracic echocardiography, transesophageal echocardiography, bioprosthetic heart valves, mechanical heart valves, prosthetic valve endocarditis, prosthetic valve thrombosis, prosthetic valve degeneration, mitral valve prosthesis, aortic valve prosthesis, sensitivity and specificity, acoustic shadowing
- MeSH terms
- Aortic Valve, Bioprosthesis, Echocardiography, Endocarditis, Female, Heart Valve Prosthesis, Humans, Male, Middle Aged, Mitral Valve, Reoperation, Sensitivity and Specificity, Thrombosis, Prosthesis-Related Infections
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.