Rapid adrenocorticotropic hormone test in practice. Retrospective review
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Retrospective analysis of the rapid adrenocorticotropic hormone (ACTH) test in a large adult population shows a marked interdependence of the basal cortisol concentration, peak cortisol concentration, and increase in cortisol concentration. Repetition of the rapid ACTH test in the same patient does not improve diagnostic accuracy. A significant number of falsely abnormal rapid ACTH test results were observed (in comparison to continuous ACTH infusion as a reference test). This supports the use of the rapid ACTH test as a screening test, but not as a diagnostic test for adrenocortical failure. It is proposed that a peak cortisol level greater than or equal to 20 micrograms/dl (550 nmol/liter) is a sufficient single criterion for normal adrenal function as assessed by the rapid ACTH test.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This threshold is based on older serum cortisol assays.”
From New Cutoffs for the Biochemical Diagnosis of Adrenal Insufficiency after ACTH Stimulation using Specific Cortisol Assays (2021) · cites this paper as [12]
In the citing paper
“As with any endocrine test, no absolute cortisol cutoff for the ACTH stimulation test is perfect for the diagnosis of AI [4, 7, 11, 12].”
From New Cutoffs for the Biochemical Diagnosis of Adrenal Insufficiency after ACTH Stimulation using Specific Cortisol Assays (2021) · cites this paper as [12]
Citations
Cites
Principles and procedures of statistics.
Steel, R. G. D., & Torrie, J. H. (1960) · Cited by 24,135
Robinson, H. F. (1961) · Agronomy Journal · doi:10.2134/agronj1961.00021962005300050002x · Cited by 17,713
A rapid test of adrenocortical function
Wood, J. B., James, V. H. T., Frankland, A. W., & Landon, J. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91526-6 · Cited by 312
Burke, C. W. (1985) · Clinics in Endocrinology and Metabolism · doi:10.1016/s0300-595x(85)80084-0 · Cited by 268
Irvine, W. J., & Barnes, E. W. (1972) · Clinics in Endocrinology and Metabolism · doi:10.1016/s0300-595x(72)80030-6 · Cited by 136
Reliability of the 30-minute ACTH test in assessing hypothalamic-pituitary-adrenal function
LINDHOLM, J., KEHLET, H., BLICHERT-TOFT, M., DINESEN, B., & RIISHEDE, J. (1978) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-47-2-272 · Cited by 134
Kehlet, H., & Binder, C. (1973) · BMJ · doi:10.1136/bmj.2.5859.147 · Cited by 134
Screening for Adrenocortical Insufficiency With Cosyntropin (Synthetic ACTH)
Speckart, P. (1971) · Archives of Internal Medicine · doi:10.1001/archinte.128.5.761 · Cited by 123
Borst, G. C., Michenfelder, H. J., & O'Brian, J. T. (1982) · New England Journal of Medicine · doi:10.1056/nejm198206173062405 · Cited by 111
Adrenocorticotropic Effects of a Synthetic Polypeptide—β1–24-Corticotropin—in Man
LANDON, J., JAMES, V. H. T., CRYER, R. J., WYNN, V., & FRANKLAND, A. W. (1964) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-24-11-1206 · Cited by 100
Cited by
Bornstein, S. R., Allolio, B., Arlt, W., Barthel, A., Don-Wauchope, A., Hammer, G. D., Husebye, E. S., Merke, D. P., Murad, M. H., Stratakis, C. A., et al. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-1710 · Cited by 1,769
“Traditionally, a peak cortisol concentration after acute stimulation with corticotropin exceeding 500 nmol/L (18 (cid:2) g/ dL) is accepted as evidence for sufficient adrenocortical responsiveness (32, 45–47).”
BackgroundDICKSTEIN, G., SHECHNER, C., NICHOLSON, W. E., ROSNER, I., SHEN-ORR, Z., ADAWI, F., & LAHAV, M. (1991) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-72-4-773 · Cited by 457
Clinical review 62: Laboratory assessment of adrenal insufficiency.
Grinspoon, S. K., & Biller, B. M. (1994) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.79.4.7962298 · Cited by 442
Measuring cortisol in serum, urine and saliva—Are our assays good enough?
El-Farhan, N., Rees, D. A., & Evans, C. (2017) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/0004563216687335 · Cited by 395
Arafah, B. M. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-0674 · Cited by 332
Metadata
- Authors
- May, M. E., & Carey, R. M.
- Affiliations
- University of Virginia Medical Center (US)
- Corresponding author
- Carey, Robert M.
- Venue
- The American Journal of Medicine
- Publisher
- Elsevier BV
- Published
- 1985-12
- Volume
- 79
- Issue
- 6
- Pages
- 679-684
- ISSN
- 0002-9343 (ISSN-L)
- OpenAlex
- W2036678313
- Cited by
- 174
- References
- 35
- Citations by year
- 2025: 3 · 2022: 3 · 2021: 7 · 2020: 4 · 2019: 1 · 2018: 3 · 2017: 2 · 2016: 2 · 2015: 2 · 2014: 4 · 2013: 5 · 2012: 3
- FWCI
- 3.12
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- The American Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
- Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- adrenocorticotropic hormone stimulation test, cortisol, adrenal insufficiency, adrenal function testing, false positives, screening test, diagnostic accuracy
- MeSH terms
- Adrenal Cortex Function Tests, Adrenal Insufficiency, Adrenocorticotropic Hormone, False Negative Reactions, False Positive Reactions, Humans, Hydrocortisone, Reference Values, Retrospective Studies, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid adrenocorticotropic hormone test in practice. Retrospective review. https://app.cochat.ai/papers/10.1016/0002-9343(85)90517-0
- The paper
- May, M. E., & Carey, R. M. (1985). Rapid adrenocorticotropic hormone test in practice. Retrospective review. The American Journal of Medicine. https://doi.org/10.1016/0002-9343(85)90517-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.