The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Fetal umbilical artery flow velocity waveforms and placental resistance: clinical significance
Abstract
Summary. Since the umbilical arteries carry fetal blood to the placenta we studied flow velocity waveforms in these vessels with a simple continuous wave Doppler system to assess placental blood flow. The ratio of peak systolic to least diastolic (A/B) flow velocity was measured as an index of placental flow resistance. In 15 normal pregnancies there was a small but significant decrease in this ratio through the last trimester. The A/B ratio was measured on 436 occasions in 168 high‐risk pregnancies. In 32 of 43 fetuses subsequently shown to be small for gestational age there was an increase in placental flow resistance with reduced, absent or even reversed flow in diastole. This finding was also present in the one fetus which died in utero. Serial studies in patients with fetal compromise indicated increasing flow resistance, a reverse of the normal trend. These results were not available to the clinician yet of 24 fetuses born before 32 weeks 13 had a high A/B ratio, and all of them were born electively. Maternal hypertension was associated with an increase in fetal placental flow resistance. The umbilical artery A/B ratio provides a new and non‐invasive measure of fetoplacental blood flow resistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Non-invasive measurement of human fetal circulation using ultrasound: a new method.
FitzGerald, D. E., & Drumm, J. E. (1977) · BMJ · doi:10.1136/bmj.2.6100.1450 · Cited by 397
FETAL BLOOD VELOCITY WAVEFORMS IN NORMAL PREGNANCY
Stuart, B., Drumm, J., FitzGerald, D. E., & Duignan, N. M. (1980) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1980.tb04613.x · Cited by 309
Pulsed Doppler with B-mode imaging for quantitative blood flow measurement
Gill, R. W. (1979) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(79)90014-0 · Cited by 265
Measurement of human fetal blood flow.
Sauders, J. B., Wright, N., & Lewis, K. O. (1980) · BMJ · doi:10.1136/bmj.280.6210.283 · Cited by 237
Fetal umbilical venous flow measured in utero by pulsed Doppler and B-mode ultrasound
Gill, R. W., Trudinger, B. J., Garrett, W. J., Kossoff, G., & Warren, P. S. (1981) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(81)90495-6 · Cited by 163
Self-citationFetal blood velocity waveforms
McCallum, W. D., Williams, C. S., Napel, S. A., & Daigle, R. E. (1978) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(78)90779-2 · Cited by 151
Physiological interpretation of doppler-shift waveforms—I theoretical considerations
Skidmore, R., & Woodcock, J. P. (1980) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(80)90057-5 · Cited by 87
Cardiovascular changes associated with fetal breathing
Fouron, J., Korcaz, Y., & Leduc, B. (1975) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(75)90864-9 · Cited by 35
AN INTRODUCTION TO SOME RECENT DEVELOPMENTS IN ARTERIAL HÆMODYNAMICS
Taylor, M. G. (1966) · Australasian Annals of Medicine · doi:10.1111/imj.1966.15.1.71 · Cited by 26
Cited by
Placental Pathology in Early-Onset and Late-Onset Fetal Growth Restriction
Mifsud, W., & Sebire, N. J. (2014) · Fetal Diagnosis and Therapy · doi:10.1159/000359969 · Cited by 328
PRENATAL STRESSORS OF HUMAN LIFE AFFECT FETAL BRAIN DEVELOPMENT
Lou, H. C., Hansen, D., Nordentoft, M., Pryds, O., Jensen, F., Nim, J., & Hetnmingsen, R. (1994) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.1994.tb08192.x · Cited by 307
Fetal and umbilical Doppler ultrasound in high-risk pregnancies
Alfirevic, Z., Stampalija, T., & Dowswell, T. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007529.pub4 · Cited by 304
Oxidative stress, placental ageing-related pathologies and adverse pregnancy outcomes
Sultana, Z., Maiti, K., Aitken, J., Morris, J., Dedman, L., & Smith, R. (2017) · American Journal of Reproductive Immunology · doi:10.1111/aji.12653 · Cited by 288
Flow velocity waveforms in the maternal uteroplacental and fetal umbilical placental circulations
Trudinger, B. J., Giles, W. B., & Cook, C. M. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(85)80016-8 · Cited by 255
Self-citation
Metadata
- Authors
- TRUDINGER, B. J., GILES, W. B., COOK, C. M., BOMBARDIERI, J., & COLLINS, L.
- Venue
- BJOG: An International Journal of Obstetrics & Gynaecology
- Publisher
- Wiley
- Published
- 1985-01
- Volume
- 92
- Issue
- 1
- Pages
- 23-30
- ISSN
- 0306-5456 (ISSN-L)
- 1470-0328
- 1471-0528
- OpenAlex
- W2079282203
- Cited by
- 561
- References
- 9
- FWCI
- 65.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fetal umbilical artery flow velocity waveforms and placental resistance: clinical significance. https://app.cochat.ai/papers/10.1111/j.1471-0528.1985.tb01044.x
- The paper
- TRUDINGER, B. J., GILES, W. B., COOK, C. M., BOMBARDIERI, J., & COLLINS, L. (1985). Fetal umbilical artery flow velocity waveforms and placental resistance: clinical significance. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/j.1471-0528.1985.tb01044.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.