Electrical resistance of brain microvascular endothelium
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
A newly developed technique for determination of the electrical resistance of the capillary wall was applied to microvessels at the surface of the frog brain. Current was injected into a capillary or venule via a microelectrode and the ensuing intravascular potential profile away from the current source was determined with a second microelectrode placed at various positions along the capillary. The membrane resistance was calculated according to the theory for leaky cables used in determinations of axon membrane resistance. The average resistance was 1870 omega . cm2. Since the surface vessels of the frog brain are devoid of glial investment but otherwise similar to brain parenchymal vessels, the results prove that the endothelium is the site of the blood-brain barrier. The electrical resistance is similar to that of a 'tight' epithelium.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, many of these experiments were performed with BMECs that had TEER values well below the range considered to be physiological (1500–8000 Ω cm2) [20–24].”
From Role of iPSC-derived pericytes on barrier function of iPSC-derived brain microvascular endothelial cells in 2D and 3D (2019) · cites this paper as [23]
Citations
Cites
Katz, B. (1966) · Medical Entomology and Zoology · Cited by 1,410
THE IONIC BASIS OF ELECTRICAL ACTIVITY IN NERVE AND MUSCLE
HODGKIN, A. L. (1951) · Biological Reviews · doi:10.1111/j.1469-185x.1951.tb01204.x · Cited by 955
The Concept of a Blood-Brain Barrier
(1980) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(80)90073-7 · Cited by 790
Lower limits of cerebrovascular permeability to nonelectrolytes in the conscious rat
Ohno, K., Pettigrew, K. D., & Rapoport, S. I. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.235.3.h299 · Cited by 444
The Concept of a Blood-Brain Barrier
Dunn, J. S. (1980) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.43.4.374-c · Cited by 380
NATURE OF SHUNT PATH AND ACTIVE SODIUM TRANSPORT PATH THROUGH FROG SKIN EPITHELIUM.
Ussing, H. H., & Windhager, E. E. (1964) · PubMed · Cited by 380
Testing of a hypothesis for osmotic opening of the blood-brain barrier
Rapoport, S., Hori, M., & Klatzo, I. (1972) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1972.223.2.323 · Cited by 377
Advances in Physiological Science
Adam, G., Mészáros, I., & Bányai, É. (1981) · Cited by 370
Regulation of brain water permeability by centrally-released vasopressin
Raichle, M. E., & Grubb, R. L. (1978) · Brain Research · doi:10.1016/0006-8993(78)90766-7 · Cited by 211
The Application of ion-selective microelectrodes
Zeuthen, T. (1981) · Medical Entomology and Zoology · Cited by 166
Research works printed but not linked: 3
- Crone, 1977, Transport of solutes and water across the blood-brain barrier, J. Physiol. (Lond.), 266, 34
- Olesen, 1982, Determination of membrane resistance of capillary endothelium in frog muscle, Acta physiol. scand., 114
- Weerasuriya, 1979, Electrical impedance of the perineurium of the frog sciatic nerve, Biophys. J., 25, 300a
Cited by
Items 101–200 of 489
Volume regulatory loss of Na, Cl, and K from rat brain during acute hyponatremia
Melton, J. E., Patlak, C. S., Pettigrew, K. D., & Cserr, H. F. (1987) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.1987.252.4.f661 · Cited by 128
Contribution of Proteoglycans to Human Immunodeficiency Virus Type 1 Brain Invasion
Bobardt, M. D., Salmon, P., Wang, L., Esko, J. D., Gabuzda, D. H., Fiala, M., Trono, D., der Schueren, B. V., David, G., & Gallay, P. A. (2004) · Journal of Virology · doi:10.1128/jvi.78.12.6567-6584.2004 · Cited by 135
Capillary permeability and how it may change.
Michel, C. C. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp017275 · Cited by 120
Logan, S., Arzua, T., Canfield, S. G., Seminary, E. R., Sison, S. L., Ebert, A. D., & Bai, X. (2019) · Comprehensive physiology · doi:10.1002/cphy.c180025 · Cited by 154
Is the pial microvessel a good model for blood-brain barrier studies?
Allt, G., & Lawrenson, J. G. (1997) · Brain Research Reviews · doi:10.1016/s0165-0173(97)00011-8 · Cited by 130
Jamieson, J. J., Linville, R. M., Ding, Y. Y., Gerecht, S., & Searson, P. C. (2019) · Fluids and Barriers of the CNS · doi:10.1186/s12987-019-0136-7 · Cited by 117
Age-related changes in the blood-brain barrier
Shah, G. N., & Mooradian, A. D. (1997) · Experimental Gerontology · doi:10.1016/s0531-5565(96)00158-1 · Cited by 130
Peroxide-scavenging deficit underlies oligodendrocyte susceptibility to oxidative stress
Juurlink, B. H. J., Thorburne, S. K., & Hertz, L. (1998) · Glia · doi:10.1002/(sici)1098-1136(199804)22:4<371::aid-glia6>3.0.co;2-6 · Cited by 196
Recent advances in understanding brain capillary function
Goldstein, G. W., & Betz, A. L. (1983) · Annals of Neurology · doi:10.1002/ana.410140402 · Cited by 113
Grifno, G. N., Farrell, A. M., Linville, R. M., Arevalo, D., Kim, J. H., Gu, L., & Searson, P. C. (2019) · Scientific Reports · doi:10.1038/s41598-019-50193-1 · Cited by 112
Morita, S., & Miyata, S. (2012) · Cell and Tissue Research · doi:10.1007/s00441-012-1421-9 · Cited by 129
“(Crone and Olesen 1982; Hawkins 2009), (2) largely limited vascular permeability of low- and high-molecular-mass trac-”
BackgroundMacdonald, J. A., Murugesan, N., & Pachter, J. S. (2010) · Journal of Neuroscience Research · doi:10.1002/jnr.22316 · Cited by 110
Neuropsychiatric Lupus, the Blood Brain Barrier, and the TWEAK/Fn14 Pathway
Stock, A. D., Wen, J., & Putterman, C. (2013) · Frontiers in Immunology · doi:10.3389/fimmu.2013.00484 · Cited by 119
“Additionally, these multilaminated junctional complexes provide very high electrical resistance, dependent on the basal parenchymal presence of astrocytes, yielding remarkably low permeability to smaller and ionic molecules (45, 46).”
BackgroundLochhead, J. J., & Davis, T. P. (2019) · Pharmaceutics · doi:10.3390/pharmaceutics11110598 · Cited by 120
Regulation of the microenvironment of peripheral nerve: Role of the blood-nerve barrier
Rechthand, E., & Rapoport, S. I. (1987) · Progress in Neurobiology · doi:10.1016/0301-0082(87)90006-2 · Cited by 108
In vitro Models of the Blood–Brain Barrier: Tools in Translational Medicine
Williams-Medina, A. R., Deblock, M. C., & Janigro, D. (2021) · Frontiers in Medical Technology · doi:10.3389/fmedt.2020.623950 · Cited by 121
Fischer, S., Wiesnet, M., Marti, H. H., Renz, D., & Schaper, W. (2004) · Journal of Cellular Physiology · doi:10.1002/jcp.10417 · Cited by 108
“The barrier properties of the BBB result from the absence of fenestrations, the low number of pinocytotic vesicles, and the presence of tight intercellular junctions between endothelial cells with extremely high electrical resistance values (Crone and Olesen, 1982).”
BackgroundButt, A. M., & Jones, H. C. (1992) · Brain Research · doi:10.1016/0006-8993(92)90374-i · Cited by 106
Induction of Blood‐Brain Barrier Endothelial Cell Differentiation a
Risau, W. (1991) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1991.tb15630.x · Cited by 112
Corneal Alternations Induced by Topical Application of Benzalkonium Chloride in Rabbit
Chen, W., Li, Z., Hu, J., Zhang, Z., Chen, L., Chen, Y., & Liu, Z. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026103 · Cited by 108
“The tight junction plays an important role in the establishment and maintenance of the barrier function of the endothelium [32,33].”
BackgroundWegener, J., Abrams, D., Willenbrink, W., Galla, H., & Janshoff, A. (2004) · BioTechniques · doi:10.2144/04374st03 · Cited by 104
Abbruscato, T. J., & Davis, T. P. (1999) · Brain Research · doi:10.1016/s0006-8993(99)01778-3 · Cited by 115
Biegel, D., Spence, D. D., & Pachter, J. S. (1995) · Brain Research · doi:10.1016/0006-8993(95)00511-n · Cited by 103
Penichet, M. L., Kang, Y.-S., Pardridge, W. M., Morrison, S. L., & Shin, S.-U. (1999) · The Journal of Immunology · doi:10.4049/jimmunol.163.8.4421 · Cited by 100
Fluids and barriers of the CNS: a historical viewpoint
Liddelow, S. A. (2011) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-8-2 · Cited by 99
Targeting Nanoparticles Across The Blood–Brain Barrier with Monoclonal Antibodies
Loureiro, J. A., Gomes, B., Coelho, M. A., Carmo Pereira, M. D., & Rocha, S. (2014) · Nanomedicine · doi:10.2217/nnm.14.27 · Cited by 98
Substances that rapidly augment ionic conductance of endothelium in cerebral venules
Olesen, S., & Crone, C. G. (1986) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1986.tb07898.x · Cited by 98
Self-citationOverview of the Assessment of Endothelial Function in Humans
Chia, P. Y., Teo, A., & Yeo, T. W. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.542567 · Cited by 104
“Although TEER has been used in vivo animal studies (157), this technique is currently too invasive in humans, and is thus characterized under in vitro techniques.”
MethodEndothelial cells: adhesion and tight junctions
Rubin, L. L. (1992) · Current Opinion in Cell Biology · doi:10.1016/0955-0674(92)90107-n · Cited by 114
Morphology and Molecular Properties of Cellular Components of Normal Cerebral Vessels
Nag, S. (2003) · Blood-Brain Barrier, · doi:10.1385/1-59259-419-0:3 · Cited by 93
Permeability across a novel microfluidic blood-tumor barrier model
Terrell-Hall, T. B., Ammer, A. G., Griffith, J. I. G., & Lockman, P. R. (2017) · Fluids and Barriers of the CNS · doi:10.1186/s12987-017-0050-9 · Cited by 92
“Second, because the cells are grown in a static media, there is no shear stress (or flow) forced on the endothelial cells, which may contribute to the low passive permeability measurements which can be as low as ~74 Ω cm2 [47], compared to in vivo values of ~2000 Ω cm2 [48].”
Nazer, B., Hong, S., & Selkoe, D. J. (2008) · Neurobiology of Disease · doi:10.1016/j.nbd.2007.12.005 · Cited by 90
Scheld, W. M. (1989) · Clinical Infectious Diseases · doi:10.1093/clinids/11.supplement_7.s1669 · Cited by 90
Transferrin-antibody fusion proteins are effective in brain targeting.
Shin, S.-U., Friden, P. M., Moran, M., Olson, T., Kang, Y., Pardridge, W. M., & Morrison, S. L. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.7.2820 · Cited by 94
Weidner, M., Hüwel, S., Ebert, F., Schwerdtle, T., Galla, H., & Humpf, H. (2013) · PLoS ONE · doi:10.1371/journal.pone.0060484 · Cited by 92
“The model can be related to the barrier function in vivo by measuring the transendothelial electrical resistance (TEER) which averages at about 1000 V*cm(2) in vitro in comparison to an estimated TEER of 1800 V*cm(2) in vivo [27].”
BackgroundBlood–Brain Barrier Breakdown in Neuroinflammation: Current In Vitro Models
Brandl, S., & Reindl, M. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms241612699 · Cited by 104
Cytokine regulation of MCP-1 expression in brain and retinal microvascular endothelial cells
Harkness, K. A., Sussman, J. D., Davies-Jones, G. A. B., Greenwood, J., & Woodroofe, M. N. (2003) · Journal of Neuroimmunology · doi:10.1016/s0165-5728(03)00251-0 · Cited by 92
“The endothelial cells (EC) of the blood–brain barrier (BBB) and blood–retinal barrier (BRB) form a selective interface between blood and neural tissue which helps to protect the homeostasis of the CNS environment (Crone and Oleson, 1982; Bradbury, 1993).”
BackgroundEngineering and monitoring cellular barrier models
Yeste, J., Illa, X., Álvarez, M., & Villa, R. (2018) · Journal of Biological Engineering · doi:10.1186/s13036-018-0108-5 · Cited by 100
“, bacterial toxins and infectious agents); in situ measurement of TEER is reported to be 1462 Ω cm(2) in rats [66] and 1850 Ω cm(2) in frogs [67].”
BackgroundThe Blood-Brain Barrier and Its Role in Inflammation
Webb, A. A., & Muir, G. D. (2000) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2000.tb02248.x · Cited by 100
Martins, T., Burgoyne, T., Kenny, B.-A., Hudson, N., Futter, C. E., Ambrósio, A. F., Silva, A. P., Greenwood, J., & Turowski, P. (2013) · Neuropharmacology · doi:10.1016/j.neuropharm.2012.08.021 · Cited by 84
“Barrier function is epitomised by the restriction of ionic currents across the BBB, with electrical resistance reaching 1500e 2000 U cm2 in vivo (Crone and Olesen, 1982; Butt et al., 1990).”
Stanimirovic, D. B., Bani-Yaghoub, M., Perkins, M., & Haqqani, A. S. (2015) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2015.974545 · Cited by 83
“Finally, a combination of RA treatment and sequential coculture of hPSC-derived BMECs with human pericytes followed by astrocytes and neurons differentiated from neural progenitors synergistically elevated TEER levels to over 5000 W cm(2), comparable to in vivo values [52,53].”
BackgroundThe blood–brain barrier and cerebral angiogenesis: lessons from the cold-injury model
Nag, S. (2002) · Trends in Molecular Medicine · doi:10.1016/s1471-4914(01)02221-3 · Cited by 85
The Anatomic Basis of the Blood-Brain Barrier
Brightman, M. (1989) · Springer eBooks · doi:10.1007/978-1-4613-0701-3_3 · Cited by 93
Comparative Physiology of the Blood-Brain Barrier
Abbott, N. J. (1992) · Handbook of experimental pharmacology · doi:10.1007/978-3-642-76894-1_15 · Cited by 98
Yamamoto, Y., Välitalo, P. A. J., Huntjens, D. R. H., Proost, J. H., Vermeulen, A., Krauwinkel, W. J. J., Beukers, M. W., van den Berg, D., Hartman, R., Wong, Y. C., et al. (2017) · CPT Pharmacometrics & Systems Pharmacology · doi:10.1002/psp4.12250 · Cited by 95
Morofuji, Y., & Nakagawa, S. (2020) · Current Pharmaceutical Design · doi:10.2174/1381612826666200224112534 · Cited by 90
Complement and blood–brain barrier integrity
Jacob, A., & Alexander, J. J. (2014) · Molecular Immunology · doi:10.1016/j.molimm.2014.06.039 · Cited by 95
AC impedance of the perineurium of the frog sciatic nerve
Weerasuriya, A., Spangler, R. A., Рапопорт, С. И., & Taylor, R. E. (1984) · Biophysical Journal · doi:10.1016/s0006-3495(84)84009-6 · Cited by 80
Miller, D. W., Audus, K. L., & Borchardt, R. T. (1992) · Methods in Cell Science · doi:10.1007/bf01409014 · Cited by 83
Zenker, D., Begley, D., Bratzke, H., Rubsamen-Waigmann, H., & Briesen, H. (2003) · The Journal of Physiology · doi:10.1111/j.1469-7793.2003.01023.x · Cited by 79
Nitz, T., Eisenblaetter, T., Psathaki, K., & Galla, H. (2003) · Brain Research · doi:10.1016/s0006-8993(03)02834-8 · Cited by 95
The role of the blood-brain barrier in HIV infection of the central nervous system
Hurwitz, A. A., Berman, J. W., & Lyman, W. D. (1994) · Advances in Neuroimmunology · doi:10.1016/s0960-5428(06)80263-9 · Cited by 78
Endothelial cell activation in central nervous system inflammation
Wu, F., Liu, L., & Zhou, H. Y. (2017) · Journal of Leukocyte Biology · doi:10.1189/jlb.3ru0816-352rr · Cited by 90
“Structure High number of mitochondria [20, 21] Unique characteristics of TJs [22] Tricellular TJs in cerebral endothelial cells [17] TJs enhanced by astrocytes [16] Paucity of pinocytotic vesicles [23, 24] Morphologic and growth characteristics [15] Function and special expression Barrier properties (impermeability) […”
BackgroundInsulin transport into the brain
Gray, S. M., & Barrett, E. J. (2018) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00240.2017 · Cited by 83
“In muscle, TEER values approximate 30 cm(2) (96), while brain endothelium TEER is 1,800 cm(2) (28).”
BackgroundLeakiness of rat brain microvessels to fluorescent probes following craniotomy
OLESEN, S. P. (1987) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1987.tb08112.x · Cited by 76
Self-citationThe blood‐brain barrier: Cellular basis
Janzer, R. C. (1993) · Journal of Inherited Metabolic Disease · doi:10.1007/bf00711897 · Cited by 96
“This is also reflected by a very high transendothelial electrical resistance comparable to the values obtained in the skin or the urothel (Crone and Olesen 1982; Butt et al 1990).”
ResultEffect of astroglial cells on hypoxia-induced permeability in PBMEC cells
Fischer, S., Wobben, M., Kleinstück, J., Renz, D., & Schaper, W. (2000) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.2000.279.4.c935 · Cited by 76
“The barrier properties of the BBB result from the absence of fenestrations and the presence of tight intercellular junctions between endothelial cells with extremely high electrical resistance values, which limits the amount of paracellular flux (18).”
BackgroundSchilling, L., & Wahl, M. (1999) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-4711-2_11 · Cited by 90
Transport Across the Blood-Brain Barrier
Fu, B. M., & Akli, L. F. A. (2018) · Advances in experimental medicine and biology · doi:10.1007/978-3-032-22285-5_15 · Cited by 88
Helms, H. C., Madelung, R., Waagepetersen, H. S., Nielsen, C. U., & Brodin, B. (2012) · Glia · doi:10.1002/glia.22321 · Cited by 74
Easton, A. S., & Abbott, N. J. (2002) · Brain Research · doi:10.1016/s0006-8993(02)03281-x · Cited by 82
Butt, A. M. (1995) · Brain Research · doi:10.1016/0006-8993(95)00811-4 · Cited by 76
Ultrastructure of frog cerebral and pial microvessels and their impermeability to lanthanum ions
Bundgaard, M. (1982) · Brain Research · doi:10.1016/0006-8993(82)91228-8 · Cited by 73
Engineering the human blood-brain barrier in vitro
Jamieson, J. J., Searson, P. C., & Gerecht, S. (2017) · Journal of Biological Engineering · doi:10.1186/s13036-017-0076-1 · Cited by 72
“While TEER values across human BMECs cannot be easily measured in vivo, TEER values across rat and frog brain ECs have been measured in the range of 1200–1900 Ω cm(2) [89, 90].”
BackgroundKatt, M. E., Mayo, L. N., Ellis, S., Mahairaki, V., Rothstein, J. D., Cheng, L., & Searson, P. C. (2019) · Fluids and Barriers of the CNS · doi:10.1186/s12987-019-0139-4 · Cited by 71
Mayeux, J. P., Teng, S. X., Katz, P. S., Gilpin, N. W., & Molina, P. E. (2014) · Behavioural Brain Research · doi:10.1016/j.bbr.2014.10.053 · Cited by 74
The Physiology of the Blood-Brain Barrier
Johansson, B. B. (1990) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-5799-5_2 · Cited by 71
Rizzo, M. T., & LEAVER, H. A. (2010) · Molecular Neurobiology · doi:10.1007/s12035-010-8132-6 · Cited by 76
“These features confer to the cerebral endothelium a resistance of 1,000– 2000 Ωcm 2 , which is 100 times higher than the resistance of peripheral endothelial cells [ 16 ].”
BackgroundNeuhaus, W., Piontek, A., Protze, J., Eichner, M., Mahringer, A., Subileau, E.-A., Lee, I.-F. M., Schulzke, J. D., Krause, G., & Piontek, J. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.01.028 · Cited by 74
“The TJs of the BBB represent one of the tightest paracellular barriers in the body [2,3].”
BackgroundKondo, T., Kinouchi, H., 川瀬, 誠., & Yoshimoto, T. (1996) · Neuroscience Letters · doi:10.1016/0304-3940(96)12555-6 · Cited by 78
Olesen, S. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015635 · Cited by 69
Self-citationThe tight-junction-specific protein ZO-l is a component of the human and rat blood-brain barriers
Watson, P. M., Anderson, J. M., Vanltallie, C. M., & Doctrow, S. R. (1991) · Neuroscience Letters · doi:10.1016/0304-3940(91)90708-2 · Cited by 69
Two components of blood‐brain barrier disruption in the rat
Easton, A. S., Sarker, M. H., & Fraser, P. A. (1997) · The Journal of Physiology · doi:10.1111/j.1469-7793.1997.613bg.x · Cited by 68
“The measurement of resistance relies on cable theory, which requires a uniform voltage dissipation over the length of the microvessel (at least 200 ìm: Crone & Olesen, 1982).”
BackgroundMethodDissecting the complexities of Alzheimer disease with in vitro models of the human brain
Blanchard, J., Victor, M. B., & Tsai, L. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-021-00578-6 · Cited by 74
ZO Proteins and Redox-Dependent Processes
González‐Mariscal, L., Quirós, M., & Díaz-Coránguez, M. (2011) · Antioxidants and Redox Signaling · doi:10.1089/ars.2011.3913 · Cited by 70
“In vertebrates, the barrier properties of the BBB depend on the low rate of fluid-phase endocytosis (136), the absence of fenestrations, and the presence of ‘‘tight’’ TJs in endothelial cells that make up brain capillaries (33).”
Hoyer, J. D., Popp, R., Meyer, J., Galla, H., & Gögelein, H. (1991) · The Journal of Membrane Biology · doi:10.1007/bf01993963 · Cited by 72
“This socalled blood-brain barrier (BBB) has properties in common with tight epithelia: first the input resistance is in the order of 1-2 kf~ �9 cm 2 [10, 13 ], and second there exist different transport mechanisms in the luminal and antiluminal (brain-facing) membrane [4].”
BackgroundBoulland, J., Rafiki, A., Levy, L. M., Storm‐Mathisen, J., & Chaudhry, F. A. (2003) · Glia · doi:10.1002/glia.10188 · Cited by 71
Wilson, H. K., Canfield, S. G., Shusta, E. V., & Palecek, S. P. (2014) · Stem Cells · doi:10.1002/stem.1797 · Cited by 72
Helms, H. C. C., Waagepetersen, H. S., Nielsen, C. U., & Brodin, B. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9237-6 · Cited by 73
“The observed effects of the HEPES, MOPS, and TESbuffered DM on the tightness of the endothelial cells, could in theory be due to (1) a change in culture media pH caused by acidification of the media when placed in the CO2 incubators, (2) an effect of the buffer concentration itself, by protecting cells from fluctuatio…”
BackgroundDrug delivery across the blood–brain barrier: why is it difficult? how to measure and improve it?
Su, Y., & Sinko, P. J. (2006) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.3.3.419 · Cited by 65
“It has been reported that the TEER values of MDCK-II cells range from ∼ 50 to 150 Ω·cm2 [86,91,92], as compared with ≥ 2000 Ω·cm2 for MDCK-I [88] or in vivo BCECs [93,94].”
BackgroundLinville, R. M., Sklar, M. B., Grifno, G. N., Nerenberg, R. F., Zhou, J., Ye, R., DeStefano, J. G., Guo, Z., Jha, R., Jamieson, J. J., et al. (2022) · Fluids and Barriers of the CNS · doi:10.1186/s12987-022-00377-1 · Cited by 67
“Similarly, transendothelial electrical resistance (TEER), a measure of barrier integrity, is expected to be 1500–8000 Ω cm2 in vivo [10, 11], but is usually less than 200 Ω cm2 for primary and immortalized BMECs [12–15].”
BackgroundPathogen translocation across the blood-brain barrier
Pulzová, L., Bhide, M. R., & Kováč, A. (2009) · FEMS Immunology & Medical Microbiology · doi:10.1111/j.1574-695x.2009.00594.x · Cited by 77
“The presence of TJs leads to high transendothelial electrical resistance values of up to 2000O cm2 as compared with 3–33O cm2 in other peripheral tissues, and this results in lower paracellular permeability (Crone & Olesen, 1982).”
BackgroundElectrical resistance of muscle capillary endothelium
Olesen, S., & Crone, C. G. (1983) · Biophysical Journal · doi:10.1016/s0006-3495(83)84366-5 · Cited by 64
“2 by Crone and Olesen (1982).”
BackgroundSelf-citationDuport, S., Robert, F., Muller, D., Grau, G., Parisi, L., & Stoppini, L. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.4.1840 · Cited by 62
Effects of Muscone on the Expression of P-gp, MMP-9 on Blood–Brain Barrier Model In Vitro
Wang, G., Wang, N., & Liao, H.-N. (2015) · Cellular and Molecular Neurobiology · doi:10.1007/s10571-015-0204-8 · Cited by 63
Praça, C., Rosa, S. C., Sevin, E., Cecchelli, R., Dehouck, M., & Ferreira, L. (2019) · Stem Cell Reports · doi:10.1016/j.stemcr.2019.08.002 · Cited by 66
In vitro screening of nanomedicines through the blood brain barrier: A critical review
Aparicio-Blanco, J., Martín‐Sabroso, C., & Torres‐Suárez, A. I. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.06.051 · Cited by 69
“These features provide the BBB with a transendothelial electrical resistance (TEER) as high as 1500 to 2000 Ωcm(2) [49] (compared with 3.”
BackgroundAssessment of Inner Blood–Retinal Barrier: Animal Models and Methods
Bora, K., Kushwah, N. S., Maurya, M., Pavlovich, M. C., Wang, Z., & Chen, J. (2023) · Cells · doi:10.3390/cells12202443 · Cited by 71
“Since its introduction in 1980s, it has become a widely approved method to determine integrity and permeability of BBB/BRB, due to its sensitivity and reliability [325].”
MethodQuantitative vitreous fluorophotometry applying a mathematical model of the eye.
Lund‐Andersen, H., Krogsaa, B., la Cour, M., & Larsen, J. (1985) · PubMed · Cited by 61
Wasielewska, J. M., & White, A. R. (2022) · Pharmaceutical Research · doi:10.1007/s11095-022-03185-2 · Cited by 69
In vitro biomimetic models for glioblastoma-a promising tool for drug response studies
Stanković, T., Ranđelović, T., Dragoj, M., Burić, S. S., Fernández, L. J., Ochoa, I., Pérez‐García, V. M., & Pešić, M. (2021) · Drug Resistance Updates · doi:10.1016/j.drup.2021.100753 · Cited by 67
Cortical microvessels during brain development: A morphometric study in the rat
Keep, R. F., & Jones, H. C. (1990) · Microvascular Research · doi:10.1016/0026-2862(90)90036-q · Cited by 70
Localization of the Blood-Brain Barrier of an Insect: Electrical Model and Analysis
Schofield, P. K., & Treherne, J. E. (1984) · Journal of Experimental Biology · doi:10.1242/jeb.109.1.319 · Cited by 56
Tunkel, A. R., Rosser, S. W., Hansen, E. J., & Scheld, W. M. (1991) · In Vitro Cellular & Developmental Biology - Animal · doi:10.1007/bf02630996 · Cited by 58
“These characteristics include positive staining for Factor VIII-related antigen, the ability to form junctional complexes in vitro (11,14), and maintenance of a high electrical resistance ( 9 ,30).”
BackgroundThe Complementary Membranes Forming the Blood‐Brain Barrier
Hawkins, R. A., Peterson, D. R., & Viña, J. R. (2002) · IUBMB Life · doi:10.1080/15216540214541 · Cited by 59
“Therefore even ions are restricted by the endothelial cell layer ( 5 ); it is now universally accepted that cerebral endothelial cells are the site of the BBB in mammals.”
BackgroundFree oxygen radicals decrease electrical resistance of microvascular endothelium in brain
OLESEN, S. ‐. (1987) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1987.tb08057.x · Cited by 59
Self-citationSecretion and Bulk Flow of Interstitial Fluid
Cserr, H. F., & Patlak, C. S. (1992) · Handbook of experimental pharmacology · doi:10.1007/978-3-642-76894-1_9 · Cited by 66
Molecular and cellular mechanisms for microbial entry into the CNS
Zhang, J., & TUOMANEN, E. I. (1999) · Journal of NeuroVirology · doi:10.3109/13550289909021288 · Cited by 61
“First, tight junctions between the BMEC possess extremely strong electrical resistance (Crone and Olesen, 1982), which restricts the amount of paracellular ¯ux.”
BackgroundTornabene, E., Helms, H. C. C., Pedersen, S. F., & Brodin, B. (2019) · PLoS ONE · doi:10.1371/journal.pone.0221103 · Cited by 61
“Bovine endothelial monolayers, co-cultured with astrocytes, can obtain a low barrier permeability and thus also a high transendothelial resistance, with values in the range of 1000– 2000 O�cm(2) [10, 11], which approaches estimated in vivo values of ~2000 O�cm(2) (determined in pial vessels) [12].”
BackgroundMenaceur, C., Gosselet, F., Fénart, L., & Saint‐Pol, J. (2021) · Cells · doi:10.3390/cells11010133 · Cited by 68
Metadata
- Authors
- Crone, C., & Olesen, S. P.
- Affiliations
- University of Copenhagen (DK)
- Venue
- Brain Research
- Publisher
- Elsevier BV
- Published
- 1982-06
- Volume
- 241
- Issue
- 1
- Pages
- 49-55
- ISSN
- 0006-8993 (ISSN-L)
- OpenAlex
- W2076634690
- Cited by
- 491
- References
- 35
- Citations by year
- 2026: 6 · 2025: 9 · 2024: 9 · 2023: 15 · 2022: 18 · 2021: 24 · 2020: 17 · 2019: 16 · 2018: 21 · 2017: 21 · 2016: 11 · 2015: 11 · 2014: 17 · 2013: 10 · 2012: 13
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Brain Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Hjerteforeningen
- Topics
- Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion Transport and Channel Regulation
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Connexins and lens biology
- Keywords
- brain microvascular endothelium, electrical resistance, capillary wall, blood-brain barrier, membrane resistance, frog brain, microvessels, tight junctions
- MeSH terms
- Animals, Capillaries, Cell Membrane, Cerebrovascular Circulation, Electric Conductivity, Endothelium, Microcirculation, Potentiometry, Rana temporaria
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.