Electrical resistance of brain microvascular endothelium
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
A newly developed technique for determination of the electrical resistance of the capillary wall was applied to microvessels at the surface of the frog brain. Current was injected into a capillary or venule via a microelectrode and the ensuing intravascular potential profile away from the current source was determined with a second microelectrode placed at various positions along the capillary. The membrane resistance was calculated according to the theory for leaky cables used in determinations of axon membrane resistance. The average resistance was 1870 omega . cm2. Since the surface vessels of the frog brain are devoid of glial investment but otherwise similar to brain parenchymal vessels, the results prove that the endothelium is the site of the blood-brain barrier. The electrical resistance is similar to that of a 'tight' epithelium.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, many of these experiments were performed with BMECs that had TEER values well below the range considered to be physiological (1500–8000 Ω cm2) [20–24].”
From Role of iPSC-derived pericytes on barrier function of iPSC-derived brain microvascular endothelial cells in 2D and 3D (2019) · cites this paper as [23]
Citations
Cites
Katz, B. (1966) · Medical Entomology and Zoology · Cited by 1,410
THE IONIC BASIS OF ELECTRICAL ACTIVITY IN NERVE AND MUSCLE
HODGKIN, A. L. (1951) · Biological Reviews · doi:10.1111/j.1469-185x.1951.tb01204.x · Cited by 955
The Concept of a Blood-Brain Barrier
(1980) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(80)90073-7 · Cited by 790
Lower limits of cerebrovascular permeability to nonelectrolytes in the conscious rat
Ohno, K., Pettigrew, K. D., & Rapoport, S. I. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.235.3.h299 · Cited by 444
The Concept of a Blood-Brain Barrier
Dunn, J. S. (1980) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.43.4.374-c · Cited by 380
NATURE OF SHUNT PATH AND ACTIVE SODIUM TRANSPORT PATH THROUGH FROG SKIN EPITHELIUM.
Ussing, H. H., & Windhager, E. E. (1964) · PubMed · Cited by 380
Testing of a hypothesis for osmotic opening of the blood-brain barrier
Rapoport, S., Hori, M., & Klatzo, I. (1972) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1972.223.2.323 · Cited by 377
Advances in Physiological Science
Adam, G., Mészáros, I., & Bányai, É. (1981) · Cited by 370
Regulation of brain water permeability by centrally-released vasopressin
Raichle, M. E., & Grubb, R. L. (1978) · Brain Research · doi:10.1016/0006-8993(78)90766-7 · Cited by 211
The Application of ion-selective microelectrodes
Zeuthen, T. (1981) · Medical Entomology and Zoology · Cited by 166
Research works printed but not linked: 3
- Crone, 1977, Transport of solutes and water across the blood-brain barrier, J. Physiol. (Lond.), 266, 34
- Olesen, 1982, Determination of membrane resistance of capillary endothelium in frog muscle, Acta physiol. scand., 114
- Weerasuriya, 1979, Electrical impedance of the perineurium of the frog sciatic nerve, Biophys. J., 25, 300a
Cited by
TEER Measurement Techniques for In Vitro Barrier Model Systems
Srinivasan, B., Kolli, A. R., Esch, M. B., Abaci, H. E., Shuler, M. L., & Hickman, J. J. (2015) · SLAS Technology · doi:10.1177/2211068214561025 · Cited by 2,145
Intranasal delivery of biologics to the central nervous system
Lochhead, J. J., & Thorne, R. G. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.11.002 · Cited by 1,214
“The presence of TJ at the BBB creates a high transendothelial electrical resistance of 1500–2000 Ω∙cm(2) compared to 3–30 Ω∙cm(2) across most peripheral microvessels [2,3].”
BackgroundHelms, H. C., Abbott, N. J., Burek, M., Cecchelli, R., Couraud, P.-O., Deli, M. A., Förster, C., Galla, H. J., Romero, I. A., Shusta, E. V., et al. (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x16630991 · Cited by 843
Patton, N., Aslam, T., MacGillivray, T., Pattie, A., Deary, I. J., & Dhillon, B. (2005) · Journal of Anatomy · doi:10.1111/j.1469-7580.2005.00395.x · Cited by 807
“In addition, it has been postulated that the asymmetric distribution of plasma membrane proteins on the endothelia (luminal vs. abluminal) creates a polarized endothelium, which helps to create an electrical resistance to permeability (Crone & Olesen, 1982).”
BackgroundInflammatory Mediators and Modulation of Blood–Brain Barrier Permeability
Abbott, N. J. (2000) · Cellular and Molecular Neurobiology · doi:10.1023/a:1007074420772 · Cited by 803
Electrical resistance across the blood-brain barrier in anaesthetized rats: a developmental study.
Butt, A. M., Jones, H. C., & Abbott, N. J. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp018243 · Cited by 775
A cell culture model of the blood-brain barrier.
Rubin, L. L., Hall, D. E., Porter, S., Barbu, K., Cannon, C., Horner, H. C., Janatpour, M., Liaw, C. W., Manning, K., & Morales, J. (1991) · The Journal of cell biology · doi:10.1083/jcb.115.6.1725 · Cited by 765
Mechanisms of macular edema: Beyond the surface
Daruich, A., Matet, A., Moulin, A., Kowalczuk, L., Nicolas, M., Sellam, A., Rothschild, P.-R., Omri, S., Gélizé, E., Jonet, L., et al. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.10.006 · Cited by 708
The blood-brain barrier: an engineering perspective
Wong, A. D., Ye, M., Levy, A. F., Rothstein, J. D., Bergles, D. E., & Searson, P. C. (2013) · Frontiers in Neuroengineering · doi:10.3389/fneng.2013.00007 · Cited by 662
“…first in vivo transendothelial electrical resistance measurements were performed on frog brain microvessels in a twoelectrode configuration with one electrode inserted into the vessel and the other used to measure the voltage drop as a function of distance along the vessel (Crone and Olesen, 1982).”
MethodPermeability Studies on In Vitro Blood–Brain Barrier Models: Physiology, Pathology, and Pharmacology
Deli, M. A., Ábrahám, C. S., Kataoka, Y., & Niwa, M. (2005) · Cellular and Molecular Neurobiology · doi:10.1007/s10571-004-1377-8 · Cited by 643
Mechanisms of fluid movement into, through and out of the brain: evaluation of the evidence
Hladky, S. B., & Barrand, M. A. (2014) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-11-26 · Cited by 633
“Instead the endothelial cells are sealed together by tight junctions that prevent (or at least greatly reduce) the passage of markers like horseradish peroxidase and lanthanum [32,34] and raise the electrical resistance to levels similar to those in tight epithelia [107,108].”
BackgroundDevelopment of the blood-brain barrier
Risau, W., & Wolburg, H. (1990) · Trends in Neurosciences · doi:10.1016/0166-2236(90)90043-a · Cited by 537
Lippmann, E. S., Al-Ahmad, A., Azarin, S. M., Palecek, S. P., & Shusta, E. V. (2014) · Scientific Reports · doi:10.1038/srep04160 · Cited by 508
Structure of the Blood–Brain Barrier and Its Role in the Transport of Amino Acids
Hawkins, R. A., O’Kane, R. L., Simpson, I. A., & Viña, J. R. (2006) · The Journal of Nutrition · doi:10.1093/jn/136.1.218s · Cited by 453
Lochhead, J. J., Yang, J., Ronaldson, P. T., & Davis, T. P. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00914 · Cited by 445
Eigenmann, D. E., Xue, G., Kim, K. S., Moses, A. V., Hamburger, M., & Oufir, M. (2013) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-10-33 · Cited by 421
“Compared to in vivo conditions where TEER values have been estimated to exceed 1000 Ωcm(2) [22,23], this is considerably lower.”
BackgroundStrategy for effective brain drug delivery
Alam, M. I., Beg, S., Samad, A., Baboota, S., Kohli, K., Ali, J., Ahuja, A., & Akbar, M. (2010) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2010.05.003 · Cited by 415
Immune Cells in the BBB Disruption After Acute Ischemic Stroke: Targets for Immune Therapy?
Qiu, Y.-M., Zhang, C.-L., Chen, A.-Q., Wang, H.-L., Zhou, Y.-F., Li, Y.-N., & Hu, B. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.678744 · Cited by 399
“M1-type monocytes secrete ROS, cytokines, and chemokines through the activation of the inflammasome to degrade TJs between ECs in the BBB.”
BackgroundInfluentialTargeted nanoparticles for drug delivery through the blood–brain barrier for Alzheimer's disease
Roney, C., Kulkarni, P., Arora, V., Antich, P., Bonte, F., Wu, A., Mallikarjuana, N. N., Manohar, S., Liang, H.-F., Kulkarni, A. R., et al. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.07.024 · Cited by 406
Erickson, M. A., & Banks, W. A. (2018) · Pharmacological Reviews · doi:10.1124/pr.117.014647 · Cited by 378
“The tight barriers of the brain vasculature were further exemplified by Crone and Olesen (1982) and by Butt et al. (1990), who showed that brain vessels have exceptionally low ion permeabilities due to very high transendothelial electrical resistance (TEER), averaging over 1000 V/cm2 in frog and…”
BackgroundDevelopment of the blood-brain barrier
Engelhardt, B. (2003) · Cell and Tissue Research · doi:10.1007/s00441-003-0751-z · Cited by 379
“The complex TJs between endothelial cells are primarily responsible for the barrier function and, unlike simple TJs, provide a high electrical resistance (about 2000 W cm2; Crone and Olesen 1982).”
BackgroundEvaluation of the MDR-MDCK cell line as a permeability screen for the blood–brain barrier
Wang, Q., Rager, J. D., Weinstein, K., Kardos, P. S., Dobson, G. L., Li, J., & Hidalgo, I. J. (2005) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2004.10.007 · Cited by 348
Hatherell, K., Couraud, P.-O., Romero, I. A., Weksler, B., & Pilkington, G. J. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.05.012 · Cited by 334
Fischer, S., Wobben, M., Marti, H. H., Renz, D., & Schaper, W. (2002) · Microvascular Research · doi:10.1006/mvre.2001.2367 · Cited by 316
“The barrier properties of the BBB result from the absense of fenestrations, the low number of pinocytotic vesicles, and the presence of tight intercellular junctions between the endothelial cells (Crone and Olesen, 1982).”
BackgroundHaseloff, R. F., Blasig, I. E., Bauer, H. C., & Bauer, H. (2005) · Cellular and Molecular Neurobiology · doi:10.1007/s10571-004-1375-x · Cited by 301
“Pial vessels from frog and rat exhibit all features of the BBB, but lack an astrocytic covering (Butt et al., 1990; Crone and Olesen, 1982).”
BackgroundCraniotomy: True Sham for Traumatic Brain Injury, or a Sham of a Sham?
Cole, J. T., Yarnell, A., Kean, W. S., Gold, E., Lewis, B., Ren, M., McMullen, D. C., Jacobowitz, D. M., Pollard, H. B., O'Neill, J. T., et al. (2011) · Journal of Neurotrauma · doi:10.1089/neu.2010.1427 · Cited by 296
“Using rat (Olesen, 1987), frog (Crone and Olesen, 1982), cat (Navari et al, 1978), and rabbit (Edvinsson and West, 1972) models, marked changes in brain microvasculature have been demonstrated following craniotomy alone.”
BackgroundEnergy metabolism in mammalian brain during development
Erecinska, M., Cherian, S., & Silver, I. A. (2004) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2004.06.003 · Cited by 297
The blood-brain barrier and glutamate
Hawkins, R. A. (2009) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2009.27462bb · Cited by 291
Hladky, S. B., & Barrand, M. A. (2016) · Fluids and Barriers of the CNS · doi:10.1186/s12987-016-0040-3 · Cited by 290
“This is less than the best available measurements of barrier conductance, 5–7 × 10−4 S cm−2 [271, 272].”
BackgroundGumbleton, M., & Audus, K. L. (2001) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.1119 · Cited by 286
Delivery of peptide and protein drugs over the blood–brain barrier
Brasnjevic, I., Steinbusch, H. W. M., Schmitz, C., & Martinez-Martinez, P. (2009) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2008.12.002 · Cited by 279
Appelt-Menzel, A., Cubukova, A., Günther, K., Edenhofer, F., Piontek, J., Krause, G., Stüber, T., Walles, H., Neuhaus, W., & Metzger, M. (2017) · Stem Cell Reports · doi:10.1016/j.stemcr.2017.02.021 · Cited by 274
“However, compared with physiological TEER values of more than 1,500 U cm2, which have been measured in or(s). ecommons.org/licenses/by-nc-nd/4.0/). capillaries of rat or frog brains (Crone and Olesen, 1982; Butt et al., 1990), the discrepancies with current in vitro models are significant.”
BackgroundInfluentialBicker, J., Alves, G., Fortuna, A., & Falcão, A. (2014) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2014.03.012 · Cited by 262
Hydrocortisone Reinforces the Blood–Brain Barrier Properties in a Serum Free Cell Culture System
Hoheisel, D., Nitz, T., Franke, H., Wegener, J., Hakvoort, A., Tilling, T., & Galla, H.-J. (1998) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1997.8051 · Cited by 260
Wagner, S., Zensi, A., Wien, S. L., Tschickardt, S. E., Maier, W., Vogel, T., Worek, F., Pietrzik, C. U., Kreuter, J., & von Briesen, H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0032568 · Cited by 257
“Therefore, these cells create a high transendothelial electrical resistance (TER) which yields in vivo values up to 2000 Vcm2 [2,3].”
BackgroundFree radicals in central nervous system ischemia.
Schmidley, J. W. (1990) · Stroke · doi:10.1161/01.str.21.7.1086 · Cited by 256
“These features allow penetration of intact microvessels with microelectrodes and determination of the electrical resistance of the endothelial layer.(20) Topical application of xanthine/XO to the pial surface of the frog brain causes a reversible decrease in electrical resistance of the endothelium, presumably reflect…”
BackgroundMyosin light chain kinase in microvascular endothelial barrier function
Shen, Q., Rigor, R. R., Pivetti, C. D., Wu, M. H., & Yuan, S. Y. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq144 · Cited by 249
Steffen, B. J., Breier, G., Butcher, E. C., Schulz, M., & Engelhardt, B. (1996) · Europe PMC (PubMed Central) · Cited by 286
In Vitro Models of the Blood-Brain Barrier
Neuhaus, W. (2020) · Handbook of Experimental Pharmacology · doi:10.1007/164_2020_370 · Cited by 236
Molecular Anatomy of the Blood-Brain Barrier as Defined by Immunocytochemistry
Dermietzel, R., & Krause, D. (1991) · International Review of Cytology · doi:10.1016/s0074-7696(08)60692-0 · Cited by 239
A dynamic in vivo-like organotypic blood-brain barrier model to probe metastatic brain tumors
Xu, H., Li, Z., Yu, Y., Sizdahkhani, S., Ho, W. S., Yin, F., Wang, L., Zhu, G., Zhang, M., Jiang, L., et al. (2016) · Scientific Reports · doi:10.1038/srep36670 · Cited by 234
Hypoxia induces permeability in brain microvessel endothelial cells via VEGF and NO
Fischer, S., Clauss, M., Wiesnet, M., Renz, D., Schaper, W., & Karliczek, G. F. (1999) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1999.276.4.c812 · Cited by 235
“In vivo, Crone and Olesen (12) reported a value of 1,800 V · cm2 in frog brain endothelial cells, whereas in vitro resistance measurements on monolayers of cultured brain capillary endothelial cells yielded values ranging from 60 to 300 V · cm2 (16, 20, 24, 47).”
BackgroundMolecular mechanisms of brain water transport
MacAulay, N. (2021) · Nature Reviews Neuroscience · doi:10.1038/s41583-021-00454-8 · Cited by 231
Eisenblätter, T., Hüwel, S., & Galla, H.-J. (2003) · Brain Research · doi:10.1016/s0006-8993(03)02401-6 · Cited by 232
Li, G., Simon, M. J., Cancel, L. M., Shi, Z.-D., Ji, X., Tarbell, J. M., Morrison, B., & Fu, B. M. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0023-5 · Cited by 231
Siddharthan, V., Kim, Y. V., Liu, S., & Kim, K. S. (2007) · Brain Research · doi:10.1016/j.brainres.2007.02.029 · Cited by 226
“The BBB cells containing tight junctions serve to restrict and control the movement of substances between the systemic circulation and brain extracellular fluid and are characterized by a high TEER and low permeability [8,11,14,18,49,59].”
BackgroundUrich, E., Lazic, S. E., Molnos, J., Wells, I., & Freskgård, P.-O. (2012) · PLoS ONE · doi:10.1371/journal.pone.0038149 · Cited by 221
“These numbers should be compared to in vivo values where the resistance has been estimated to be approximately 1500–8000 V/cm2 [67,68,69].”
BackgroundInfluentialMicrofabricated blood vessels for modeling the vascular transport barrier
Polacheck, W. J., Kutys, M. L., Tefft, J. B., & Chen, C. S. (2019) · Nature Protocols · doi:10.1038/s41596-019-0144-8 · Cited by 215
Steffen, B. J., Butcher, E. C., & Engelhardt, B. (1994) · PubMed Central · Cited by 256
Förster, C., Silwedel, C., Golenhofen, N., Burek, M., Kietz, S., Mankertz, J., & Drenckhahn, D. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.084038 · Cited by 214
“…hydrocortisone treatment for primary porcine BCECs (Hoheisel et al. 1998) and cells from epithelial origin (Nguyen & Neville, 1998; Woo et al. 2000), and are comparable to the TER of brain capillaries in vivo, which was estimated to average out at 2000 cm2 (Crone & Olesen, 1982; Rubin et al. 1991).”
BackgroundDanziger, J., & Zeidel, M. L. (2015) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.10741013 · Cited by 200
Linville, R. M., DeStefano, J. G., Sklar, M. B., Xu, Z., Farrell, A. M., Bogorad, M. I., Chu, C., Walczak, P., Cheng, L., Mahairaki, V., et al. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.10.023 · Cited by 199
“physiological (1,500 – 8,000 Ω cm(2)).(9-12) To overcome this limitation, many existing BBB models incorporate supporting cell types of the neu rovascular unit (i.”
Quagliarello, V. J., Long, W. J., & Scheld, W. M. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112407 · Cited by 198
Cerebrovascular Permeability Coefficients to Sodium, Potassium, and Chloride
Smith, Q. R., & Rapoport, S. I. (1986) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1986.tb08491.x · Cited by 196
Wolff, A., Antfolk, M., Brodin, B., & Tenje, M. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24329 · Cited by 191
Al-Obaidi, M. M. J., & Desa, M. N. M. (2018) · Cellular and Molecular Neurobiology · doi:10.1007/s10571-018-0609-2 · Cited by 188
Bradbury, M. (1993) · Experimental Physiology · doi:10.1113/expphysiol.1993.sp003698 · Cited by 191
The blood-brain barrier. Transport across the cerebral endothelium.
Bradbury, M. W. (1985) · Circulation Research · doi:10.1161/01.res.57.2.213 · Cited by 189
Tight Junctions in Brain Barriers During Central Nervous System Inflammation
Coisne, C., & Engelhardt, B. (2011) · Antioxidants & Redox Signaling · doi:10.1089/ars.2011.3929 · Cited by 186
“…adjacent CNS microvascular endothelial cells are therefore primarily responsible for the unique restriction of the paracellular diffusion pathway be-tween the endothelial cells, which establishes unlike in simple TJs, a high electrical resistance of about 1800–2000 O $ cm 2 across the BBB (14, 21).”
Regulation of Endothelial Barrier Function
Yuan, S. Y., & Rigor, R. R. (2011) · Colloquium Series on Integrated Systems Physiology: From Molecule to Function · doi:10.4199/c00025ed1v01y201101isp013 · Cited by 177
Marino, A., Tricinci, O., Battaglini, M., Filippeschi, C., Mattoli, V., Sinibaldi, E., & Ciofani, G. (2018) · Small · doi:10.1002/smll.201702959 · Cited by 179
Engelhardt, B., Vestweber, D., Hallmann, R., & Schulz, M. (1997) · Blood · doi:10.1182/blood.v90.11.4459 · Cited by 176
Morphological and functional characterization of an in vitro blood–brain barrier model
Stanness, K. A., Westrum, L. E., Fornaciari, E., Mascagni, P., Nelson, J. A., Stenglein, S. G., Myers, T., & Janigro, D. (1997) · Brain Research · doi:10.1016/s0006-8993(97)00829-9 · Cited by 171
Rap1 GTPase Inhibits Leukocyte Transmigration by Promoting Endothelial Barrier Function
Wittchen, E. S., Worthylake, R. A., Kelly, P., Casey, P. J., Quilliam, L. A., & Burridge, K. (2005) · Journal of Biological Chemistry · doi:10.1074/jbc.m412595200 · Cited by 168
Fatty acid transport into the brain: Of fatty acid fables and lipid tails
Mitchell, R. W., & Hatch, G. M. (2011) · Prostaglandins, Leukotrienes and Essential Fatty Acids (PLEFA) · doi:10.1016/j.plefa.2011.04.007 · Cited by 167
Alyaudtin, R. N., Reichel, A., Löbenberg, R., Ramge, P., Kreuter, J., & Begley, D. J. (2001) · Journal of Drug Targeting · doi:10.3109/10611860108997929 · Cited by 166
Cerebrospinal fluid production by the choroid plexus: a century of barrier research revisited
MacAulay, N., Keep, R. F., & Zeuthen, T. (2022) · Fluids and Barriers of the CNS · doi:10.1186/s12987-022-00323-1 · Cited by 161
“high endothelial electrical resistance representing poor transendothelial permeability towards ions [67, 68].”
BackgroundReview: Molecular pathogenesis of blood–brain barrier breakdown in acute brain injury
Nag, S., Kapadia, A., & Stewart, D. J. (2011) · Neuropathology and Applied Neurobiology · doi:10.1111/j.1365-2990.2010.01138.x · Cited by 161
Ghandour, M. S., Langley, O. K., Zhu, X. L., Waheed, A., & Sly, W. S. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.15.6823 · Cited by 158
Development of the blood‐brain barrier: A historical point of view
Ribatti, D., Nico, B., Crivellato, E., & Artico, M. (2006) · The Anatomical Record Part B: The New Anatomist · doi:10.1002/ar.b.20087 · Cited by 143
Bioavailability and Transport of Peptides and Peptide Drugs into the Brain
Egleton, R. D., & Davis, T. P. (1997) · Peptides · doi:10.1016/s0196-9781(97)00242-8 · Cited by 169
Greenwood, J., Pryce, G., Devine, L., Male, D. K., dos‐Santos, W. L. C., Calder, V. L., & Adamson, P. (1996) · Journal of Neuroimmunology · doi:10.1016/s0165-5728(96)00130-0 · Cited by 161
Arora, S., Layek, B., & Singh, J. (2021) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.0c00461 · Cited by 149
Amirifar, L., Shamloo, A., Nasiri, R., de Barros, N. R., Wang, Z. Z., Unluturk, B. D., Libanori, A., Ievglevskyi, O., Diltemiz, S. E., Sances, S., et al. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121531 · Cited by 147
Fischer, S., Wiesnet, M., Renz, D., & Schaper, W. K. A. (2005) · European Journal of Cell Biology · doi:10.1016/j.ejcb.2005.03.002 · Cited by 150
Raimondi, I., Izzo, L., Tunesi, M., Comar, M., Albani, D., & Giordano, C. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00435 · Cited by 156
“For mammalian BBBs, the physiological values for the TEER ranges from 1,500 to 2,000 ·cm2 (Crone and Olesen, 1982; Butt et al., 1990).”
BackgroundIn Vitro Models of the Blood–Brain Barrier
Czupalla, C. J., Liebner, S., & Devraj, K. (2014) · Methods in molecular biology · doi:10.1007/978-1-4939-0320-7_34 · Cited by 171
“Decades ago, it was shown that there is a direct correlation between EC permeability and its electrical resistance [ 20 ].”
BackgroundReview: in vitro microvessel models
Bogorad, M. I., DeStefano, J., Karlsson, J., Wong, A. D., Gerecht, S., & Searson, P. C. (2015) · Lab on a Chip · doi:10.1039/c5lc00832h · Cited by 145
Benchmarking in vitro tissue-engineered blood–brain barrier models
DeStefano, J. G., Jamieson, J. J., Linville, R. M., & Searson, P. C. (2018) · Fluids and Barriers of the CNS · doi:10.1186/s12987-018-0117-2 · Cited by 142
Differentiation of the brain vasculature: the answer came blowing by the Wnt
Liebner, S., & Plate, K. H. (2010) · Journal of Angiogenesis Research · doi:10.1186/2040-2384-2-1 · Cited by 141
“The complex TJs between brain ECs establish a high electrical resistance across the endothelial barrier (about 2000Ω × cm(2)) that is the hallmark of the BBB [8].”
BackgroundA new type of amiloride-sensitive cationic channel in endothelial cells of brain microvessels
Vigne, P., Champigny, G., Marsault, R., Barbry, P., Frelin, C., & Lazdunski, M. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)83285-9 · Cited by 142
Biology and Models of the Blood–Brain Barrier
Hajal, C., Le Roi, B., Kamm, R. D., & Maoz, B. M. (2021) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-082120-042814 · Cited by 137
“Measured in vivo values in animals 4 × 10−7 cm/s [rat (51)] 1,300 /cm2 [frog (52)]”
BackgroundRisau, W., Engelhardt, B., & Wekerle, H. (1990) · The Journal of cell biology · doi:10.1083/jcb.110.5.1757 · Cited by 138
“It should be noted that BBB endothelia in situ are highly specialized showing unusual enzyme patterns, membrane receptors, complex intercellular junctions, and lack of pinocytotic vesicles (Coomber and Stewart, 1985; Crone and Olesen, 1982; Nagy et al., 1984; Jefferies et al., 1984; Risau et al., 1986a,b).”
BackgroundThe Cerebral Microvessels in Culture, an Update
Joó, F. (1992) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1992.tb09272.x · Cited by 138
Impedance analysis of epithelial and endothelial cell monolayers cultured on gold surfaces
Wegener, J., Sieber, M., & Galla, H. (1996) · Journal of Biochemical and Biophysical Methods · doi:10.1016/0165-022x(96)00005-x · Cited by 151
Pekny, M., Stanness, K. A., Eliasson, C., Betsholtz, C., & Janigro, D. (1998) · PubMed · Cited by 135
Hamm, S., Dehouck, B., Kraus, J., Wolburg‐Buchholz, K., Wolburg, H., Risau, W., Cecchelli, R., Engelhardt, B., & Dehouck, M. (2004) · Cell and Tissue Research · doi:10.1007/s00441-003-0825-y · Cited by 138
“The complex tight junctions (TJs) between endothelial cells are primarily responsible for the barrier function and unlike simple TJs provide a high electrical resistance (about 2,000 W cm2) (Crone and Olesen 1982).”
BackgroundTight‐Junctional Modification as the Basis of Osmotic Opening of the Blood‐Brain Barriera
RAPOPORT, S. I., & ROBINSON, P. J. (1986) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1986.tb27155.x · Cited by 132
Where is the blood–brain barrier … really?
Ge, S., Song, L., & Pachter, J. S. (2005) · Journal of Neuroscience Research · doi:10.1002/jnr.20313 · Cited by 133
Vigh, J. P., Kincses, A., Ozgür, B., Walter, F. R., Santa-Maria, A. R., Valkai, S., Vastag, M., Neuhaus, W., Brodin, B., Dér, A., et al. (2021) · Micromachines · doi:10.3390/mi12060685 · Cited by 127
“The first direct measurement of the electrical resistance of pial microvenules was performed on anesthetized frogs at room temperature [3].”
BackgroundMethodResultInfluentialDeterminants of Passive Drug Entry into the Central Nervous System
Habgood, M. D., Begley, D. J., & Abbott, N. J. (2000) · Cellular and Molecular Neurobiology · doi:10.1023/a:1007001923498 · Cited by 152
Villabona-Rueda, A., Erice, C., Pardo, C. A., & Stins, M. F. (2019) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2019.00405 · Cited by 128
Recent progress in translational engineered in vitro models of the central nervous system
Nikolakopoulou, P., Rauti, R., Voulgaris, D., Shlomy, I., Maoz, B. M., & Herland, A. (2020) · Brain · doi:10.1093/brain/awaa268 · Cited by 145
“However, TEER of human primary BMECs (does typically not exceed 200 X (cid:2) cm 2 (Mackic et al. , 1999; Zenker et al. , 2003), which accounts for only 10% of in vivo TEER measurements of the blood–brain barrier in rats and frogs (Crone and Olesen, 1982; Butt et al. , 1990).”
Neutrophils and the blood–brain barrier dysfunction after trauma
Scholz, M., Cinatl, J., Schädel‐Höpfner, M., & Windolf, J. (2007) · Medicinal Research Reviews · doi:10.1002/med.20064 · Cited by 126
Electrical resistance and macromolecular permeability of brain endothelial monolayer cultures
Rutten, M. J., Hoover, R. L., & Karnovsky, M. J. (1987) · Brain Research · doi:10.1016/0006-8993(87)90513-0 · Cited by 131
Extracellular RNA mediates endothelial-cell permeability via vascular endothelial growth factor
Fischer, S., Gerriets, T., Wessels, C., Walberer, M., Kostin, S., Stolz, E., Zheleva, K., Hocke, A., Hippenstiel, S., & Preissner, K. T. (2007) · Blood · doi:10.1182/blood-2006-08-040691 · Cited by 124
“In the heparin treatment group, no vessel occlusion ( ) is seen, whereas edema formation (3) remained.”
BackgroundEndothelial cells of the brain and other organ systems: Some similarities and differences
Joo, F. (1996) · Progress in Neurobiology · doi:10.1016/0301-0082(95)00046-1 · Cited by 134
Modeling the blood–brain barrier using stem cell sources
Lippmann, E. S., Al-Ahmad, A., Palecek, S. P., & Shusta, E. V. (2013) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-10-2 · Cited by 122
“As a result of this adult brain microenvironment and in contrast to the developmental BBB, the adult BBB boasts an elevated TEER, measured at average values between 1000–2000 Ωxcm(2) (and maximum values up to 6000 Ωxcm(2)) and a correspondingly lower passive permeability to molecular tracers [21,25,26].”
Garcia, C. M., Darland, D. C., Massingham, L. J., & D'Amore, P. A. (2004) · Developmental Brain Research · doi:10.1016/j.devbrainres.2004.05.008 · Cited by 132
Colgan, O. C., Ferguson, G., Collins, N. T., Murphy, R. P., Meade, G., Cahill, P. A., & Cummins, P. M. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01177.2006 · Cited by 121
“This barrier forms an effective seal to prevent paracellular diffusion of charged particles, proteins, ions, hydrophilic molecules, and hormones, thus protecting the CNS from changes in blood composition (6, 10, 21).”
Metadata
- Authors
- Crone, C., & Olesen, S. P.
- Affiliations
- University of Copenhagen (DK)
- Venue
- Brain Research
- Publisher
- Elsevier BV
- Published
- 1982-06
- Volume
- 241
- Issue
- 1
- Pages
- 49-55
- ISSN
- 0006-8993 (ISSN-L)
- OpenAlex
- W2076634690
- Cited by
- 491
- References
- 35
- Citations by year
- 2026: 6 · 2025: 9 · 2024: 9 · 2023: 15 · 2022: 18 · 2021: 24 · 2020: 17 · 2019: 16 · 2018: 21 · 2017: 21 · 2016: 11 · 2015: 11 · 2014: 17 · 2013: 10 · 2012: 13
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Brain Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Hjerteforeningen
- Topics
- Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion Transport and Channel Regulation
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Connexins and lens biology
- Keywords
- brain microvascular endothelium, electrical resistance, capillary wall, blood-brain barrier, membrane resistance, frog brain, microvessels, tight junctions
- MeSH terms
- Animals, Capillaries, Cell Membrane, Cerebrovascular Circulation, Electric Conductivity, Endothelium, Microcirculation, Potentiometry, Rana temporaria
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.