Electrical resistance of brain microvascular endothelium
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
A newly developed technique for determination of the electrical resistance of the capillary wall was applied to microvessels at the surface of the frog brain. Current was injected into a capillary or venule via a microelectrode and the ensuing intravascular potential profile away from the current source was determined with a second microelectrode placed at various positions along the capillary. The membrane resistance was calculated according to the theory for leaky cables used in determinations of axon membrane resistance. The average resistance was 1870 omega . cm2. Since the surface vessels of the frog brain are devoid of glial investment but otherwise similar to brain parenchymal vessels, the results prove that the endothelium is the site of the blood-brain barrier. The electrical resistance is similar to that of a 'tight' epithelium.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, many of these experiments were performed with BMECs that had TEER values well below the range considered to be physiological (1500–8000 Ω cm2) [20–24].”
From Role of iPSC-derived pericytes on barrier function of iPSC-derived brain microvascular endothelial cells in 2D and 3D (2019) · cites this paper as [23]
Citations
Cites
Katz, B. (1966) · Medical Entomology and Zoology · Cited by 1,410
THE IONIC BASIS OF ELECTRICAL ACTIVITY IN NERVE AND MUSCLE
HODGKIN, A. L. (1951) · Biological Reviews · doi:10.1111/j.1469-185x.1951.tb01204.x · Cited by 955
The Concept of a Blood-Brain Barrier
(1980) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(80)90073-7 · Cited by 790
Lower limits of cerebrovascular permeability to nonelectrolytes in the conscious rat
Ohno, K., Pettigrew, K. D., & Rapoport, S. I. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.235.3.h299 · Cited by 444
The Concept of a Blood-Brain Barrier
Dunn, J. S. (1980) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.43.4.374-c · Cited by 380
NATURE OF SHUNT PATH AND ACTIVE SODIUM TRANSPORT PATH THROUGH FROG SKIN EPITHELIUM.
Ussing, H. H., & Windhager, E. E. (1964) · PubMed · Cited by 380
Testing of a hypothesis for osmotic opening of the blood-brain barrier
Rapoport, S., Hori, M., & Klatzo, I. (1972) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1972.223.2.323 · Cited by 377
Advances in Physiological Science
Adam, G., Mészáros, I., & Bányai, É. (1981) · Cited by 370
Regulation of brain water permeability by centrally-released vasopressin
Raichle, M. E., & Grubb, R. L. (1978) · Brain Research · doi:10.1016/0006-8993(78)90766-7 · Cited by 211
The Application of ion-selective microelectrodes
Zeuthen, T. (1981) · Medical Entomology and Zoology · Cited by 166
Research works printed but not linked: 3
- Crone, 1977, Transport of solutes and water across the blood-brain barrier, J. Physiol. (Lond.), 266, 34
- Olesen, 1982, Determination of membrane resistance of capillary endothelium in frog muscle, Acta physiol. scand., 114
- Weerasuriya, 1979, Electrical impedance of the perineurium of the frog sciatic nerve, Biophys. J., 25, 300a
Cited by
Items 201–300 of 489
Bai, W., & Zhou, Y. (2017) · Frontiers in Molecular Neuroscience · doi:10.3389/fnmol.2017.00400 · Cited by 65
“It has a high electrical impedance (≈2000 /cm2), and restricts even the passage of ions (Crone and Olesen, 1982; Sifat et al., 2017).”
BackgroundThe role of blood vessels in high-resolution volume conductor head modeling of EEG
Fiederer, L. D. J., Vorwerk, J., Lucka, F. F., Dannhauer, M., Yang, S., Dümpelmann, M., Schulze‐Bonhage, A., Aertsen, A., Speck, O., Wolters, C. H., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.041 · Cited by 62
“As researchers (Butt et al., 1990; Crone and Olesen, 1982) have measured the electrical resistance of the brain endothelium (although in rat and frog), two paths towards a solution are currently investigated: (i) implementing separate compartments for blood vessel endothelium and lumen, requiring a…”
Quagliarello, V. J., Ma, A., Stukenbrok, H., & Palade, G. E. (1991) · The Journal of experimental medicine · doi:10.1084/jem.174.3.657 · Cited by 56
Valdovinos-Flores, C., & Gonsebatt, M. E. (2012) · Neurochemistry International · doi:10.1016/j.neuint.2012.05.019 · Cited by 60
3D hydrogel models of the neurovascular unit to investigate blood–brain barrier dysfunction
Potjewyd, G., Kellett, K. A. B., & Hooper, N. M. (2021) · Neuronal Signaling · doi:10.1042/ns20210027 · Cited by 56
Gao, X., Xu, J., Yao, T., Liu, X., Zhang, H., & Zhan, C. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114362 · Cited by 59
Vogel, P. A., Halpin, S. T., Martin, R. S., & Spence, D. M. (2011) · Analytical Chemistry · doi:10.1021/ac2004746 · Cited by 54
Form and Function of the Vertebrate and Invertebrate Blood-Brain Barriers
Dunton, A. D., Göpel, T., Ho, D. H., & Burggren, W. W. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms222212111 · Cited by 58
“This creates the high electrical resistance typical of other tight junctions [151], which was suggested to result from the endothelial cells themselves given that at least in the frog brain there is no glial covering of the subarachnoid vessels [143].”
BackgroundCantrill, C., Skinner, R. A., Rothwell, N. J., & Penny, J. I. (2012) · Brain Research · doi:10.1016/j.brainres.2012.08.031 · Cited by 62
Mittapalli, R. K., Manda, V. K., Adkins, C. E., Geldenhuys, W. J., & Lockman, P. R. (2010) · Therapeutic Delivery · doi:10.4155/tde.10.76 · Cited by 65
Blood–Brain and Spinal Cord Barriers in Stress
SHARMA, H. S. (2004) · Elsevier eBooks · doi:10.1016/b978-012639011-7/50019-x · Cited by 57
Appelt‐Menzel, A., Oerter, S., Mathew, S., Haferkamp, U., Hartmann, C., Jung, M., Neuhaus, W., & Pleß, O. (2020) · Current Protocols in Stem Cell Biology · doi:10.1002/cpsc.122 · Cited by 57
Measurement of filtration coefficient in single cerebral microvessels of the frog.
Fraser, P. A., Dallas, A. D., & Davies, S. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp018026 · Cited by 52
Pontine lesions produce apneusis in the rat
Morrison, S. F., Cravo, S. L. D., & Wilfehrt, H. M. (1994) · Brain Research · doi:10.1016/0006-8993(94)90320-4 · Cited by 51
Kristensen, M., & Brodin, B. (2017) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2017.04.080 · Cited by 55
Physiological and Pathological Factors Affecting Drug Delivery to the Brain by Nanoparticles
Islam, Y., Leach, A. G., Smith, J. A., Pluchino, S., Coxon, C. R., Sivakumaran, M., Downing, J. E., Fatokun, A. A., Teixidò, M., & Ehtezazi, T. (2021) · Advanced Science · doi:10.1002/advs.202002085 · Cited by 57
Acute effects of bradykinin on cerebral microvascular permeability in the anaesthetized rat
Sarker, M. H., Hu, D. ‐., & Fraser, P. A. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.00177.x · Cited by 51
“…may be estimated independently of pressure by using single microvessel techniques (Easton & Fraser, 1994), an approach pioneered in the brain by Crone & Olesen (1982) who used changes in the electrical cable properties of 500 ìm lengths of pial venular capillaries as the basis of the…”
MethodCrone, C. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015338 · Cited by 50
Self-citationReview of Design Considerations for Brain-on-a-Chip Models
Cameron, T., Bennet, T. J., Rowe, E. M., Anwer, M., Wellington, C. L., & Cheung, K. C. (2021) · Micromachines · doi:10.3390/mi12040441 · Cited by 54
“Animal studies suggest that a physiological TEER value of the brain microvasculature is between 1500 and 8000 Ω·cm2 [70,71], compared to peripheral capillary vessels, which have TEERs of 2–20 Ω·cm2 [72,73].”
BackgroundSmith, Q. R. (1992) · Handbook of experimental pharmacology · doi:10.1007/978-3-642-76894-1_2 · Cited by 49
Helms, H. C. C., Hersom, M., Kuhlmann, L. B., Badolo, L., Nielsen, C. U., & Brodin, B. (2014) · The AAPS Journal · doi:10.1208/s12248-014-9628-1 · Cited by 55
“[21], these cell culture models displayed transendothelial electrical resistance (TEER) values in the range of 100–300 Ω·cm [20, 22, 23], which are relatively low compared to the estimated in vivo barrier TEER of 1,000–2,000 Ω·cm [25, 26].”
BackgroundInteraction of T Lymphocytes with Cerebral Endothelial Cells in vitro
Wekerle, H., Engelhardt, B., Risau, W., & Meyermann, R. (1991) · Brain Pathology · doi:10.1111/j.1750-3639.1991.tb00647.x · Cited by 55
Urbanczyk, M., Zbinden, A., & Schenke‐Layland, K. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114323 · Cited by 59
C-Type Natriuretic Peptide Modulates Permeability of the Blood–Brain Barrier
Bohara, M., Kambe, Y., Nagayama, T., Tokimura, H., Arita, K., & Miyata, A. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2013.234 · Cited by 51
Morphology and Properties of Brain Endothelial Cells
Nag, S. (2010) · Methods in molecular biology · doi:10.1007/978-1-60761-938-3_1 · Cited by 56
Endothelial cell infection and hemostasis
Sahni, S. (2006) · Thrombosis Research · doi:10.1016/j.thromres.2006.06.006 · Cited by 49
Rydkina, E. B., Turpin, L. C., & Sahni, S. (2010) · Infection and Immunity · doi:10.1128/iai.01335-09 · Cited by 57
Zhu, Z. B., Makhija, S. K., Lu, B., Wang, M., Rivera, Á. A., Preuss, M. A., Zhou, F., Siegal, G. P., Alvarez, R. D., & Curiel, D. T. (2004) · Virology · doi:10.1016/j.virol.2004.04.021 · Cited by 52
“, 2003), and across the blood–brain barrier (Butt et al., 1990; Crone and Olesen, 1982) because of epithelial and endothelial cell barriers.”
BackgroundCassella, J. P., Lawrenson, J. G., Allt, G., & Firth, J. A. (1996) · PubMed Central · Cited by 51
In vitro models to predict blood-brain barrier permeability
Eddy, E. P., Maleef, B. E., Hart, T. K., & Smith, P. L. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(96)00435-8 · Cited by 45
Pathophysiology of Blood–Brain Barrier Breakdown
Nag, S. (2003) · Blood-Brain Barrier, · doi:10.1385/1-59259-419-0:97 · Cited by 45
Ultrastructure of Brain Endothelium
Brightman, M. (1992) · Handbook of experimental pharmacology · doi:10.1007/978-3-642-76894-1_1 · Cited by 50
Yamashita, M., Aoki, H., Hashita, T., Iwao, T., & Matsunaga, T. (2020) · Fluids and Barriers of the CNS · doi:10.1186/s12987-020-00197-1 · Cited by 47
In vitro and in vivo optimization of liposomal nanoparticles based brain targeted vgf gene therapy
Arora, S., & Singh, J. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.121095 · Cited by 46
Chung, C., Chang, Y.-C., Ding, Y., Lim, K. J., Liu, Q., Zhu, L.-J., Zhang, W., Lu, T., Molostvov, G., Zehnder, D., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0176817 · Cited by 45
“(the major component of the blood-brain barrier (BBB)) could be distinguished from other tissue ECs due to several unique characteristics, with the most important being the highly resistant tight junctions that provide high transendothelial electrical resistance and retard paracellular flux [25, 26].”
BackgroundMicrophysiological systems for recapitulating physiology and function of blood-brain barrier
Seo, S., Kim, H., Sung, J. H., Choi, N., Lee, K., & Kim, H. N. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119732 · Cited by 47
“TEER can be calculated based on the theory developed by Crone & Olesen in 1982 by using various parameters including the resistivity of blood, radius of the vessel, vessel cross-sectional area, and length constant [202,203].”
MethodNormal and abnormal development of the blood‐brain barrier
Farrell, C. L., & Risau, W. (1994) · Microscopy Research and Technique · doi:10.1002/jemt.1070270604 · Cited by 48
“The resistance has never been measured directly in intraparenchymal vessels but rather has been inferred from the measurement of high resistances in the leptomeningeal vessels in frog (Crone and Olesen, 1982) and rat (Butt et al.”
BackgroundGlucose transport by isolated plasma membranes of the bovine blood-brain barrier
Lee, W. J., Peterson, D. R., Sukowski, E. J., & Hawkins, R. A. (1997) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1997.272.5.c1552 · Cited by 44
Peptide Mediated Brain Delivery of Nano- and Submicroparticles: A Synergistic Approach
McCully, M., Sánchez‐Navarro, M., Teixidò, M., & Giralt, E. (2018) · Current Pharmaceutical Design · doi:10.2174/1381612824666171201115126 · Cited by 49
“These tight junctions produce high Transendothelial Electrical Resistance (TEER) values as high as 2000 Ω·cm [2, 9].”
BackgroundRegulation of Brain Volume Under Isosmotic and Anisosmotic Conditions
Cserr, H. F., & Patlak, C. S. (1991) · Advances in comparative and environmental physiology · doi:10.1007/978-3-642-76226-0_3 · Cited by 43
Mulac, D., Hüwel, S., Galla, H., & Humpf, H. (2011) · Molecular Nutrition & Food Research · doi:10.1002/mnfr.201100431 · Cited by 45
“With the use of this model system, a very good comparison to the in vivosetting (1800O cm(2)) is possible [26].”
MethodImpaired Regulation of pH Homeostasis by Oxidative Stress in Rat Brain Capillary Endothelial Cells
Sipos, I., Törőcsik, B., Tretter, L., & Ádám‐Vizi, V. (2005) · Cellular and Molecular Neurobiology · doi:10.1007/s10571-004-1379-6 · Cited by 43
“, 2001) resulting in high transendothelial electrical resistance (Crone and Olesen, 1982).”
BackgroundBradbury, M. W. B., & Lightman, S. L. (1990) · Eye · doi:10.1038/eye.1990.36 · Cited by 43
Effects of Cardiac Microstructure on Propagating Electrical Waveforms
Spach, M. S., & Barr, R. C. (2000) · Circulation Research · doi:10.1161/01.res.86.2.e23 · Cited by 42
Transport across the Blood-Brain Barrier
Bradbury, M. W. B. (1989) · Springer eBooks · doi:10.1007/978-1-4613-0701-3_5 · Cited by 46
Shamul, J. G., Wang, Z., Gong, H., Ou, W., White, A. M., Garcia, D. P. M., Gu, S., Clyne, A. M., Quiñones‐Hinojosa, A., & He, X. (2024) · Nature Biomedical Engineering · doi:10.1038/s41551-024-01250-2 · Cited by 46
“Although this increase was observed, the TEER still differed greatly from that of normal BBBs (1,500–8,000 Ω cm 2 ) 114,115 .”
Chen, W., Hu, J., Zhang, Z., Chen, L., Xie, H., Dong, N., Chen, Y., & Liu, Z. (2012) · PLoS ONE · doi:10.1371/journal.pone.0040893 · Cited by 43
The Blood-Brain Barrier and the Regulation of Amino Acid Uptake and Availability to Brain
Smith, Q. R. (1991) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-5931-9_6 · Cited by 45
Helms, H. C. C., & Brodin, B. (2014) · Methods in molecular biology · doi:10.1007/978-1-4939-0320-7_30 · Cited by 50
Microcirculation and Capillary Exchange
Renkin, E. M., & Crone, C. G. (1996) · Springer eBooks · doi:10.1007/978-3-642-60946-6_98 · Cited by 39
Self-citationChapter 19: The development of ion regulation at the blood-brain barrier
Jones, H. C., Keep, R. F., & Butt, A. M. (1992) · Progress in brain research · doi:10.1016/s0079-6123(08)62326-2 · Cited by 44
The Blood‐Brain Barrier as a Tight Epithelium: Where Is Information Lacking?
Crone, C. (1986) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1986.tb27149.x · Cited by 39
Self-citationMolecular Biology of Blood-Brain Barrier Ontogenesis and Function
Risau, W. (1994) · Springer eBooks · doi:10.1007/978-3-7091-9334-1_28 · Cited by 45
Carrier‐Mediated Transport of Chloride Across the Blood‐Brain Barrier
Smith, Q. R., & Rapoport, S. I. (1984) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1984.tb02747.x · Cited by 38
Engdahl, E., van Schijndel, M. D. M., Voulgaris, D., Criscio, M. D., Ramsbottom, K. A., Rigden, D. J., Herland, A., & Rüegg, J. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22115534 · Cited by 37
“Statistics To compare TEER values, BCRP blockage, BPRP expression (qPCR), LDH release between the treatment groups (DMSO, BPA, BPS, BPF), and the Kruskal–Wallis test were applied.”
BackgroundInfluentialMicrocirculatory Exchange Function
Durán, W. N., Sánchez, F. A., & Breslin, J. W. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-374530-9.00004-8 · Cited by 38
Bouafsoun, A., Helali, S., Mebarek, S., Zeiller, C., Prigent, A., Othmane, A., Kerkeni, A., Jaffrezic-Renault, N. J., & Ponsonnet, L. (2006) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2006.05.012 · Cited by 36
Current aspects of the development of the blood‐brain barrier
Joó, F. (1987) · International Journal of Developmental Neuroscience · doi:10.1016/0736-5748(87)90013-x · Cited by 39
Mapping the fine structure of cortical activity with different micro-ECoG electrode array geometries
Wang, X., Gkogkidis, C. A., Iljina, O., Fiederer, L. D. J., Henle, C., Mader, I., Kaminsky, J., Stieglitz, T., Gierthmuehlen, M., & Ball, T. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa785e · Cited by 35
Piantino, M., Kang, D.-H., Furihata, T., Nakatani, N., Nakayama-Kitamura, K., Shigemoto‐Mogami, Y., Sato, K., & Matsusaki, M. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100324 · Cited by 38
Neutrophils both reduce and increase permeability in a cell culture model of the blood–brain barrier
Inglis, V. I., Jones, M. P., Tse, A. D. Y., & Easton, A. S. (2003) · Brain Research · doi:10.1016/j.brainres.2003.11.031 · Cited by 36
Olesen, S. P. (1987) · The Journal of Physiology · doi:10.1113/jphysiol.1987.sp016562 · Cited by 35
Self-citationMolecular Architecture of the Brain Microvasculature: Perspective on Blood-Brain Transport
Drewes, L. R. (2001) · Journal of Molecular Neuroscience · doi:10.1385/jmn:16:2-3:93 · Cited by 35
“Consequently, the electrical resistance across the brain endothelium is very high (>1000–3000 Ω-cm 2 ) ( Crone and Olesen, 1982 ), except for areas of the brain known as the circumventricular organs that have low resistance because their capillaries are fenestrated and lack tight junctions.”
BackgroundThe Effects of Propofol on a Human in vitro Blood-Brain Barrier Model
Hughes, J. M., Neese, O., Bieber, D. D., Lewis, K. A., Ahmadi, L. M., Parsons, D., & Canfield, S. G. (2022) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2022.835649 · Cited by 35
“The enhanced BBB properties of iPSC-derived BMECs compared to other in vitro models in addition to their human origin enable them to screen the efficacy and safety of a number of anesthetics (Crone and Olesen, 1982).”
BackgroundSpach, M. S., Heidlage, J. F., Dolber, P. C., & Barr, R. C. (1998) · Circulation Research · doi:10.1161/01.res.83.11.1144 · Cited by 33
Si, J., Liu, Z., Gu, F., Jin, X., & Ma, Y. (2025) · International Journal of Oncology · doi:10.3892/ijo.2025.5789 · Cited by 38
Cultured Vascular Endothelial Cells of the Brain.
Deli, M. A., & Joó, F. (1996) · The Keio Journal of Medicine · doi:10.2302/kjm.45.183 · Cited by 34
What is the Blood-Brain Barrier? A Molecular Perspective
Drewes, L. R. (1999) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-4711-2_10 · Cited by 33
Regulation of Permeability Across the Blood-Brain Barrier
Easton, A. S. (2013) · Advances in experimental medicine and biology · doi:10.1007/978-1-4614-4711-5_1 · Cited by 38
Chen, L., Cruz, E., Oikari, L. E., Padmanabhan, P., Song, J. H., & Götz, J. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114517 · Cited by 38
Intranasal Drug Delivery to the Brain
Lochhead, J. J., & Thorne, R. G. (2013) · AAPS advances in the pharmaceutical sciences series · doi:10.1007/978-1-4614-9105-7_14 · Cited by 39
The blood-brain barrier in and out of cell culture
Rubin, L. L. (1991) · Current Opinion in Neurobiology · doi:10.1016/0959-4388(91)90053-a · Cited by 39
Erben, M., Decker, S., Franke, H., & Galla, H. (1995) · Journal of Biochemical and Biophysical Methods · doi:10.1016/0165-022x(95)00011-x · Cited by 31
Joó, F., Tósaki, Á., Oláh, Z., & Koltai, M. (1989) · Brain Research · doi:10.1016/0006-8993(89)90439-3 · Cited by 31
In vitro and in vivo models of BBB to evaluate brain targeting drug delivery
Sharma, B., Luhach, K., & Kulkarni, G. T. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-814001-7.00004-4 · Cited by 35
The tight junction: Structure and function
Hirsch, M., & Noske, W. (1993) · Micron · doi:10.1016/0968-4328(93)90057-8 · Cited by 34
Transcellular Barriers to Glucose Delivery in the Body
Klip, A., Bock, K. D., Bilan, P. J., & Richter, E. A. (2024) · Annual Review of Physiology · doi:10.1146/annurev-physiol-042022-031657 · Cited by 31
Chen, J., Chen, T.-G., Chang, Y.-C., Chen, C., & Chen, R. (2015) · Toxicology · doi:10.1016/j.tox.2015.11.006 · Cited by 31
Blood-Brain Barrier (BBB) Permeability and Transport Measurement In Vitro and In Vivo
Fu, B. M., Zhao, Z., & Zhu, D. (2020) · Methods in molecular biology · doi:10.1007/7651_2020_308 · Cited by 36
Piantino, M., Louis, F., Shigemoto‐Mogami, Y., Nakayama-Kitamura, K., Sato, K., Yamaguchi, T., Kawabata, K., Yamamoto, S., Iwasaki, S., Hirabayashi, H., et al. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100232 · Cited by 34
“6 values from the brains of other species such as rat [54] and frog [55] have been estimated to exceed 1000 Ω cm2.”
BackgroundBlood–brain borders: a proposal to address limitations of historical blood–brain barrier terminology
Badaut, J., Ghersi‐Egea, J., Thorne, R. G., & Konsman, J. P. (2024) · Fluids and Barriers of the CNS · doi:10.1186/s12987-023-00478-5 · Cited by 33
“Among the reasons put forward are the ability of the epithelium to secrete fluid, along with a reportedly low TEER (~ 150 Ω · cm 2 in bullfrog; [30]) as compared to what has been measured across endothelial cells of pial blood vessels (~ 1500–2000 Ω · cm 2 ; [31, 32]).”
ResultBiegel, D., & Pachter, J. S. (1994) · In Vitro Cellular & Developmental Biology - Animal · doi:10.1007/bf02631256 · Cited by 29
“We therefore evaluated the TEER across monolayer cultures of BMEC grown on collagen plugs, as elevated TEER values indicate the presence of tight junctions and are characteristic of blood-brainbarrier (BBB) endothelia in vivo ( 4 ).”
BackgroundIn Vitro Effects of Fentanyl, Methohexital, and Thiopental on Brain Endothelial Permeability
Fischer, S., Renz, D., Schaper, W. K. A., & Karliczek, G. F. (1995) · Anesthesiology · doi:10.1097/00000542-199502000-00015 · Cited by 31
Transport properties of vertebrate blood-nerve barrier: Comparison with blood-brain barrier
Wadhwani, K. C., & Rapoport, S. I. (1994) · Progress in Neurobiology · doi:10.1016/0301-0082(94)90002-7 · Cited by 33
HMEC-1 adopt the mixed amoeboid-mesenchymal migration type during EndMT
Kryczka, J. M., Przygodzka, P., Bogusz, H., & Boncela, J. (2017) · European Journal of Cell Biology · doi:10.1016/j.ejcb.2017.04.002 · Cited by 27
“Endothelial cells establish close cell–cell connections, which form a solid barrier, through desmosomes and tight and adherent junction proteins (Crone and Olesen, 1982; Siflinger-Birnboim et al., 1987; Yuan and Rigor, 2010).”
BackgroundVasculature organotropism in drug delivery
Amruta, A., Iannotta, D., Cheetham, S. W., Lammers, T., & Wolfram, J. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.115054 · Cited by 29
Evaluation of Endothelial Cell Adhesion onto Different Protein/Gold Electrodes by EIS
Bouafsoun, A., Helali, S., Othmane, A., Kerkeni, A., Prigent, A., Jaffrezic-Renault, N. J., Bessueille, F., Léonard, D., & Ponsonnet, L. (2007) · Macromolecular Bioscience · doi:10.1002/mabi.200600263 · Cited by 30
Endothelial Protrusions in Junctional Integrity and Barrier Function
Alves, N. G., Motawe, Z. Y., Yuan, S. Y., & Breslin, J. W. (2018) · Current topics in membranes · doi:10.1016/bs.ctm.2018.08.006 · Cited by 29
“This was performed in frog capillaries/postcapillary venules of the mesentery, muscle, and brain, which yielded electrical resistances of 0.95, 23, and 1870 Ω·cm2, respectively (Crone & Christensen, 1981; Crone & Olesen, 1982; Olesen & Crone, 1983).”
BackgroundInfluentialThe blood-nerve barrier: an in vivo lanthanum tracer study.
Mackenzie, M. L., Ghabriel, M. N., & Allt, G. (1987) · PubMed · Cited by 26
Ahmad, N., Kiriako, G., Saliba, J., Abla, K. K., El-Sabban, M. E., & Mhanna, R. (2024) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.4c00599 · Cited by 28
Xia, Z.-Y., Luo, C., Liu, B., Bian, X.-Q., Yang, L., Pang, A. M., Xu, Y., Tan, H.-M., & Zhao, Y. (2019) · Phytomedicine · doi:10.1016/j.phymed.2019.153158 · Cited by 27
RAMSOHOYE, P. V., & Fritz, I. B. (1998) · Neurochemical Research · doi:10.1023/a:1020932121378 · Cited by 34
“1545 niques developed by Crone and Olsen (1) in the amphibian brain, the electrical resistances measured across the cerebral endothelium of mammals exceeds that of 1000 ohm.”
BackgroundLi, X., Simo, L., Zhao, Q., Kim, E., Ding, Y., & Geng, X. (2025) · European Journal of Neuroscience · doi:10.1111/ejn.16663 · Cited by 30
“Cerebrovascular ECs form a highly restrictive barrier, with low ion permeability due to their high membrane resistance (Crone and Olesen 1982).”
Chen, W., Dong, N., Huang, C., Zhang, Z., Hu, J., Xie, H., Pan, J., & Liu, Z. (2014) · PLoS ONE · doi:10.1371/journal.pone.0089205 · Cited by 24
Goldstein, G. W., Betz, A. L., Bowman, P. D., & Dorovini, K. (1986) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1986.tb27151.x · Cited by 24
Aigner, A. M., Wolf, S., & Gassen, H. G. (1997) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199700241 · Cited by 25
Finite element modeling to analyze TEER values across silicon nanomembranes
Khire, T. S., Nehilla, B. J., Getpreecharsawas, J., Gracheva, M. E., Waugh, R. E., & McGrath, J. L. (2018) · Biomedical Microdevices · doi:10.1007/s10544-017-0251-7 · Cited by 25
“In vivo electrical impedance measurements of the frog blood-brain-barrier is a gold standard in the field of (cerebral) vascular biology (Crone and Olesen 1982).”
InfluentialOchiai, Y., Uchida, Y., Tachikawa, M., Couraud, P., & Terasaki, T. (2019) · Journal of Neurochemistry · doi:10.1111/jnc.14722 · Cited by 24
“The transendothelial electrical resistance value of hCMEC/D3 cells in monolayer culture is about 30–50 Ω cm2 (Weksler et al. 2013), which is much lower than the estimated in vivo value of 1500–2000 Ω cm2 (Crone and Olesen 1982; Butt et al. 1990; Laterra and Goldstein 2000).”
BackgroundDetrimental or beneficial: Role of endothelial ENaC in vascular function
Zhang, J., Yuan, H., Chen, S., & Zhang, Z. (2022) · Journal of Cellular Physiology · doi:10.1002/jcp.30505 · Cited by 23
“…that has tight epithelium properties in controlling the movements of ions, water, oxygen, and nutrients between blood and interstitium (Crone & Olesen, 1982; Kapela et al., 2018), and dysfunction of the barrier usually contributes to various kind of disease (Dongaonkar et al., 2010).”
BackgroundDelivery of Metals to Brain and the Role of the Blood-Brain Barrier
Smith, Q. R., Rabin, O., & Chikhale, E. G. (1997) · Springer eBooks · doi:10.1007/978-1-4899-0197-2_7 · Cited by 26
Metadata
- Authors
- Crone, C., & Olesen, S. P.
- Affiliations
- University of Copenhagen (DK)
- Venue
- Brain Research
- Publisher
- Elsevier BV
- Published
- 1982-06
- Volume
- 241
- Issue
- 1
- Pages
- 49-55
- ISSN
- 0006-8993 (ISSN-L)
- OpenAlex
- W2076634690
- Cited by
- 491
- References
- 35
- Citations by year
- 2026: 6 · 2025: 9 · 2024: 9 · 2023: 15 · 2022: 18 · 2021: 24 · 2020: 17 · 2019: 16 · 2018: 21 · 2017: 21 · 2016: 11 · 2015: 11 · 2014: 17 · 2013: 10 · 2012: 13
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Brain Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Hjerteforeningen
- Topics
- Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion Transport and Channel Regulation
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Connexins and lens biology
- Keywords
- brain microvascular endothelium, electrical resistance, capillary wall, blood-brain barrier, membrane resistance, frog brain, microvessels, tight junctions
- MeSH terms
- Animals, Capillaries, Cell Membrane, Cerebrovascular Circulation, Electric Conductivity, Endothelium, Microcirculation, Potentiometry, Rana temporaria
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.