Short- and long-term reproducibility of time and frequency domain heart rate variability measurements in normal subjects
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To obtain data relating to the reproducibility of the time and frequency domain measurements obtained from 10-min ECG recordings. METHODS: Eighteen normal volunteers underwent evaluations of time and frequency domain heart rate variability 2 weeks and 7 months after baseline analysis. The time domain parameters were mean NN, the standard deviation of NN intervals, the percentage of successive NN intervals > 50 ms and the root mean square successive difference of NN intervals. The frequency domain evaluations (total power, low frequency, and high frequency) were made by means of both the Fast Fourier Transform algorithm (FFT) and the autoregressive method (AR) from 10-min ECG recordings made under three different conditions: rest, controlled respiration, and after a passive head-up tilt test. Reproducibility was evaluated by means of the interclass correlation coefficient (ICC), comparing baseline values with the results obtained at the second week and the seventh month. Time domain evaluation were also made from 10-min ECG. RESULTS: All of the time domain measurements had an ICC > or = 0.75, except for the standard deviation of NN intervals, which had an ICC of 0.57. The frequency domain parameters obtained by means of either FFT or AR showed similar reproducibility. Low frequency was reproducible under all three conditions, total power only at rest, and high frequency only during controlled respiration. CONCLUSION: The reproducibility of frequency domain parameters depends on the analysed condition. These results are of primary importance when the effects of drugs or other interventions on heart rate variability are under investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Cardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569
Assessment of autonomic function in humans by heart rate spectral analysis
Pomeranz, B., Macaulay, R. J., Caudill, M. A., Kutz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J., et al. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h151 · Cited by 2,876
Montano, N., Ruscone, T. G., Porta, A., Lombardi, F., Pagani, M., & Malliani, A. (1994) · Circulation · doi:10.1161/01.cir.90.4.1826 · Cited by 1,108
Analysis of Heart Rate Variability
SAYKRS, B. M. (1973) · Ergonomics · doi:10.1080/00140137308924479 · Cited by 946
Changes in autonomic regulation induced by physical training in mild hypertension.
Pagani, M., Somers, V, Furlan, R., Dell'Orto, S., Conway, J., Baselli, G., Cerutti, S., Sleight, P., & Malliani, A. (1988) · Hypertension · doi:10.1161/01.hyp.12.6.600 · Cited by 745
Modulation of cardiac autonomic activity during and immediately after exercise
Arai, Y., Saul, J. P., Albrecht, P., Hartley, L. H., Lilly, L. S., Cohen, R. J., & Colucci, W. S. (1989) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1989.256.1.h132 · Cited by 703
Cited by
Melillo, P., Bracale, M., & Pecchia, L. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-96 · Cited by 328
“Some studies [44,45] showed that different breathing conditions may have an impact on the reproducibility of HRV.”
BackgroundThe reliability of short-term measurements of heart rate variability
Sandercock, G. R. H., Bromley, P. D., & Brodie, D. A. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.09.013 · Cited by 307
“One example of the former type of assessment [59] produced CVs in healthy subjects, similarly to those reported for resting conditions.”
BackgroundResultInfluentialValidity and Reliability of Short-Term Heart-Rate Variability from the Polar S810
NUNAN, D., DONOVAN, G., JAKOVLJEVIC, D. G., HODGES, L. D., SANDERCOCK, G. R. H., & BRODIE, D. A. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318184a4b1 · Cited by 302
Heart rate variability measures: a fresh look at reliability
Pinna, G. D., Maestri, R., Torunski, A., Danilowicz-Szymanowicz, L., Szwoch, M., La Rovere, M. T., & Raczak, G. (2007) · Clinical Science · doi:10.1042/cs20070055 · Cited by 261
De Meersman, R. E., & Stein, P. K. (2007) · Biological Psychology · doi:10.1016/j.biopsycho.2006.04.008 · Cited by 228
Quigley, K. S., Gianaros, P. J., Norman, G. J., Jennings, J. R., Berntson, G. G., & de Geus, E. J. C. (2024) · Psychophysiology · doi:10.1111/psyp.14604 · Cited by 225
Stability of heart rate variability indices reflecting parasympathetic activity.
Bertsch, K., Hagemann, D., Naumann, E., Schächinger, H., & Schulz, A. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2011.01341.x · Cited by 185
Comparison of time and frequency domain measures of RSA in ambulatory recordings
Goedhart, A. D., Van Der Sluis, S., Houtveen, J. H., Willemsen, G., & De Geus, E. J. C. (2007) · Psychophysiology · doi:10.1111/j.1469-8986.2006.00490.x · Cited by 180
“79 for the 24-h RMSSD level (Pitzalis et al., 1996).”
Repeatability of heart rate variability measures
Schroeder, E. B., Whitsel, E. A., Evans, G. W., Prineas, R. J., Chambless, L. E., & Heiss, G. (2004) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2004.04.004 · Cited by 170
Five-minute heart rate variability can predict obstructive angiographic coronary disease
Kotecha, D., New, G., Flather, M. D., Eccleston, D., Pepper, J., & Krum, H. (2012) · Heart · doi:10.1136/heartjnl-2011-300033 · Cited by 63
Vagal nerve activity as a moderator of brain-immune relationships
Ohira, H., Matsunaga, M., Osumi, T., Fukuyama, S., Shinoda, J., Yamada, J., & Gidron, Y. (2013) · Journal of Neuroimmunology · doi:10.1016/j.jneuroim.2013.04.011 · Cited by 47
“As the average of HRV values in normal people in a resting state is around 50% (Pitzalis et al., 1996), means of HRV in the low and high HRV groups in the present study suggest that the median split could make an appropriate contrast between the two groups in this study (Table 1).”
ResultNeijts, M., Van Lien, R., Kupper, N., Boomsma, D., Willemsen, G., & de Geus, E. J. C. (2014) · Psychophysiology · doi:10.1111/psyp.12246 · Cited by 29
Metadata
- Authors
- Pitzalis, M.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-08
- Volume
- 32
- Issue
- 2
- Pages
- 226-233
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2111840911
- Cited by
- 162
- References
- 25
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.