Validity and Reliability of Short-Term Heart-Rate Variability from the Polar S810

Open access
NUNAN, DAVID, DONOVAN, GAY, JAKOVLJEVIC, DJORDJE G., HODGES, LYNETTE D., SANDERCOCK, GAVIN R. H., BRODIE, DAVID A.·2009·Medicine & Science in Sports & Exercise

Abstract

PURPOSE: : To assess the validity and the reliability of short-term resting heart-rate variability (HRV) measures obtained using the Polar S810 heart-rate monitor and accompanying software. METHODS: : Measures of HRV were obtained from 5-min R to R wave (RR) interval data for 19 males and 14 females during 10 min of quiet rest on three separate occasions at 1-wk intervals using the Polar S810. Criterion measures of HRV were obtained simultaneously using the CardioPerfect (CP; Medical Graphics Corporation, St Paul, MN) 12-lead ECG module. Measures of validity of the Polar S810 were estimated by regression analysis, and measures of reliability of both devices were estimated by analysis of change scores. Measures of the SD of normal-to-normal intervals (SDNN), the root mean square of successive differences (RMSSD), and the low-frequency (LF) and the high-frequency (HF) spectral power and their ratio (LF/HF) were analyzed after log transformation, whereas mean RR and LF and HF in normalized units were analyzed without transformation. RESULTS: : There were marginal differences between the Polar and the CP mean measures of HRV, and the uncertainty in the differences was small. The Polar S810 demonstrated high correlations (0.85-0.99) with CP for all measures of HRV indicating good to near-perfect validity. Except for the low- and the high-frequency normalized units, Polar S810 did not add any substantial technical error to the within-subject variability in the repeated measurements of HRV. CONCLUSION: : HRV measures obtained with the Polar S810 and accompanying software have no appreciable bias or additional random error in comparison with criterion measures, but the measures are inherently unreliable over a 1-wk interval. Reliability of HRV from longer (e.g., 10 min) and/or consecutive 5-min RR recordings needs to be investigated with the Polar and criterion instruments.

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e318184a4b1

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
NUNAN, D., DONOVAN, G., JAKOVLJEVIC, D. G., HODGES, L. D., SANDERCOCK, G. R. H., & BRODIE, D. A.
Affiliations
  • Buckinghamshire New University (GB)
  • University of Bedfordshire (GB)
  • University of Essex (GB)
Venue
Medicine & Science in Sports & Exercise
Published
2009-01
Volume
41
Issue
1
Pages
243-250
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2014229115
Cited by
302
References
44
Citations by year
2026: 3 · 2025: 2 · 2024: 14 · 2023: 8 · 2022: 21 · 2021: 19 · 2020: 16 · 2019: 18 · 2018: 24 · 2017: 18 · 2016: 23 · 2015: 21 · 2014: 30 · 2013: 22 · 2012: 22
FWCI
9.95
Type
journal article
Language
en
Open access
Locations
  • Medicine & Science in Sports & Exercise (publishedVersion)
  • PubMed (publishedVersion)
  • Bucks New University Repository (Bucks New University) (submittedVersion)
  • Open Access at Essex (University of Essex) (submittedVersion)
  • Newcastle University ePrints (Newcastle Univesity)
Funders
Medical Research Council (MC_G0802536)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
Keywords
heart rate variability, heart rate monitors, device validity, test-retest reliability, RR interval, spectral power, within-person variability, resting heart rate
MeSH terms
Adult, Algorithms, Female, Heart Rate, Humans, Male, Middle Aged, Surveys and Questionnaires, Regression Analysis, Software, Time Factors, Reproducibility of Results, Electrocardiography, Ambulatory, Confidence Intervals

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review