Detection of single fluorescent molecules
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-Speed DNA Sequencing: An Approach Based Upon Fluorescence Detection of Single Molecules
Jett, J. H., Keller, R. A., Martin, J. C., Marrone, B. L., Moyzis, R. K., Ratliff, R. L., Seitzinger, N. K., Shera, E. B., & Stewart, C. C. (1989) · Journal of Biomolecular Structure and Dynamics · doi:10.1080/07391102.1989.10507773 · Cited by 176
Self-citationPeck, K., Stryer, L., Glazer, A. N., & Mathies, R. A. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.11.4087 · Cited by 175
Cited by
Probing Single Molecules and Single Nanoparticles by Surface-Enhanced Raman Scattering
Nie, S., & Emory, S. R. (1997) · Science · doi:10.1126/science.275.5303.1102 · Cited by 10,238
Fluorescence Spectroscopy of Single Biomolecules
Weiss, S. (1999) · Science · doi:10.1126/science.283.5408.1676 · Cited by 2,046
Single Molecules Observed by Near-Field Scanning Optical Microscopy
Betzig, E., & Chichester, R. J. (1993) · Science · doi:10.1126/science.262.5138.1422 · Cited by 1,262
Single-quantum-dot-based DNA nanosensor
Zhang, C.-Y., Yeh, H.-C., Kuroki, M. T., & Wang, T.-H. (2005) · Nature Materials · doi:10.1038/nmat1508 · Cited by 953
Methods of single-molecule fluorescence spectroscopy and microscopy
Moerner, W. E., & Fromm, D. P. (2003) · Review of Scientific Instruments · doi:10.1063/1.1589587 · Cited by 881
Metadata
- Authors
- Brooks Shera, E., Seitzinger, N. K., Davis, L. M., Keller, R. A., & Soper, S. A.
- Venue
- Chemical Physics Letters
- Publisher
- Elsevier BV
- Published
- 1990-11
- Volume
- 174
- Issue
- 6
- Pages
- 553-557
- ISSN
- 0009-2614 (ISSN-L)
- OpenAlex
- W1984748886
- Cited by
- 477
- References
- 2
- FWCI
- 13.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.