Cited by 43

The DOI matches its Crossref record.

Rapid and uniform electromagnetic heating of aqueous cryoprotectant solutions from cryogenic temperatures

Ruggera, Paul S., Fahy, Gregory M.·1990·Cryobiology

Abstract

Devitrification (ice formation during warming) is one of the primary obstacles to successful organ vitrification (solidification without ice formation). The only feasible approach to overcoming either devitrification or its damaging effects in a large organ appears at present to be the use of some form of electromagnetic heating (EH) to achieve the required high heating rates. One complication of EH in this application is the need for warming within a steel pressure vessel. We have previously reported that resonant radiofrequency (RF) helical coils provide very uniform heating at ambient temperatures and low heating rates and can be modified for coaxial power transmission, which is necessary if only one cable is to penetrate through the wall of the pressure vessel. We now report our initial studies using a modified helical coil, high RF input power, and cryogenic aqueous cryoprotectant solutions [60% (w/v) solution of 4.37 M dimethylsulfoxide and 4.37 M acetamide in water and 50% (w/w) 1,2-propanediol]. We also describe the electronic equipment required for this type of research. Temperatures were monitored during high-power conditions with Luxtron fiberoptic probes. Thermometry was complicated by the use of catheters needed for probe insertion and guidance. The highest heating rates we observed using catheters occurred at temperatures ranging from about -70 to -40 degrees C, the temperature zone where devitrification usually appears in unstable solutions during slow warming.…

Overview

Integrity signals

Registry

Crossref · 10.1016/0011-2240(90)90035-3

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 15

  1. Allen, 1988, CDRH RF phantom for hyperthermia systems evaluations, Int. J. Hyperthermia, 4, 17, 10.3109/02656738809032046 · DOI
  2. Angell, 1980, Heat capacity changes in glass-forming aqueous solutions and the glass transition in vitreous water, J. Phys. Chem, 84, 268, 10.1021/j100440a009 · DOI
  3. Anhalt, 1990, The CDRH helix—An in vivo evaluation, Int. J. Hyperthermia, 6, 241, 10.3109/02656739009140819 · DOI
  4. Bonner, 1977, Heat capacities of urea and water in water and dimethylformamide, J. Amer. Chem. Soc, 99, 2898, 10.1021/ja00451a009 · DOI
  5. Boutron, 1979, Stability of amorphous state in the system water-1,2-propanediol, Cryobiology, 16, 557, 10.1016/0011-2240(79)90074-9 · DOI
  6. Fahy, 1981, Prospects for vitrification of whole organs, Cryobiology, 18, 617, 10.1016/0011-2240(81)90150-4 · DOI
  7. Fahy, 1987, Vitrification of multicellular systems and whole organs, Cryobiology, 24, 580, 10.1016/0011-2240(87)90152-0 · DOI
  8. Fahy, 1987, Some emerging principles underlying the physical properties, biological actions, and utility of vitrification solutions, Cryobiology, 24, 196, 10.1016/0011-2240(87)90023-X · DOI
  9. Fahy, 1984, Vitrification as an approach to cryopreservation, Cryobiology, 21, 407, 10.1016/0011-2240(84)90079-8 · DOI · Paper page
  10. Fahy, 1990, Physical problems with vitrification of large systems, Cryobiology, 27, 492, 10.1016/0011-2240(90)90038-6 · DOI · Paper page
  11. Kiyohara, 1975, Volumes and heat capacities of dimethylsulfoxide, acetone, and acetamide in water and of some electrolytes in these mixed aqueous solvents, Canad. J. chem, 53, 3263, 10.1139/v75-465 · DOI
  12. MacFarlane, 1981, Homogeneous nucleation and glass formation in cryoprotective systems at high pressures, Cryo-Letters, 2, 353
  13. Olsen, 1989, Simple nonperturbing temperature probe for microwave/radio frequency dosimetry, Bioelectromagnetics, 10, 209, 10.1002/bem.2250100210 · DOI
  14. Ruggera, 1984, Development of a family of RF helical coil applicators which produce transversely uniform axially distributed heating in cylindrical fat-muscle phantoms, IEEE Trans. Biomed. Eng, BME-31, 98, 10.1109/TBME.1984.325375 · DOI
  15. Waterman, 1985, The response of thermometer probes inserted into catheters, Med. Phys, 12, 368, 10.1118/1.595698 · DOI

Cited by

Sorted by citations

See all 43

Metadata

Authors
Ruggera, P. S., & Fahy, G. M.
Venue
Cryobiology
Publisher
Elsevier BV
Published
1990-10
Volume
27
Issue
5
Pages
465-478
ISSN
0011-2240
Cited by
43
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review