Abstract

Starting from the observation that the part above 6 Hz of the power spectrum of force tremor during isometric contractions can be related to the unfused twitches of motor units firing asynchronously, an attempt was made to study the usefulness of force tremor spectral analysis as a global descriptor of motoneurone pool activity. To compensate for the mechanical low-pass filter characteristic of skeletal muscle which leads to increased damping of mechanical ripples at higher frequencies, a numerical compensation rule was derived from data obtained by electrical microstimulation of small ensembles of motor units (MUs). Hidden line plots of consecutive partially overlapping spectra allowed visualization of changes in spectral composition during ongoing muscle activity. The resulting muscle activity spectra (MAS) showed broad peaks according to the range of onset firing rates in normal subjects. These tended to shift to higher frequencies with increasing force. Under conditions with increased synchronization of the MUs these broad peaks were replaced by sharp peaks corresponding to the burst repetition rate. Patients with different motor dysfunctions were selected to illustrate how alterations of MU activity are reflected in the MAS. Decreased or increased firing rates were observed as well as abnormal states of synchronization. It is concluded that the MAS provides useful information about some aspects of the discharge characteristics of ensembles of MUs and therefore represents a method to monitor some qualitative 'image' of the MU activities within a muscle.

Overview

Integrity signals

Registry

Crossref · 10.1016/0013-4694(86)90087-8

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • This 8-12 Hz tremor corresponds in peak frequency to the isometrically recorded force tremor emerging during prolonged isometric contractions at maximal forces.

    “Furthermore this 8-12 Hz tremor corresponds in peak frequency to the isometrically recorded force tremor emerging during prolonged isometric contractions at maximal forces.2”

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 3

  1. Freund, 1978, The relationship between physiological and pathological tremor, Vol. 5, 66
  2. Hömberg, 1983, Mechanical and neural factors in generation of physiological and pathological tremors, Neurosci. Lett., 170
  3. Reiners, 1985, Veränderungen des Entladungsverhaltens motorischer Einheiten bei spinalen Muskelatrophien und hereditären motorischen und sensiblen Neuropathien, Z. EEG-EMG, 16, 37

Cited by

Sorted by citations

Metadata

Authors
Hömberg, V, Reiners, K., Hefter, H., & Freund, H.-J.
Affiliations
Düsseldorf University Hospital (DE)
Corresponding author
Hömberg, V
Venue
Electroencephalography and Clinical Neurophysiology
Publisher
Elsevier BV
Published
1986-03
Volume
63
Issue
3
Pages
209-222
ISSN
0013-4694 (ISSN-L)
OpenAlex
W1983154747
Cited by
35
References
41
Citations by year
2022: 1 · 2015: 1
FWCI
2.56
Type
journal article
Language
en
Open access
closed
Locations
  • Electroencephalography and Clinical Neurophysiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
  • Health Sciences › Medicine › Clinical Neurology › Peripheral Nerve Disorders
Keywords
motor unit activity, motor unit synchronization, motor unit firing rate
MeSH terms
Adolescent, Adult, Aged, Humans, Isometric Contraction, Middle Aged, Motor Neurons, Movement Disorders, Muscles, Spectrum Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review