CoChat

Rhodopsin levels and retinal function in cats during recovery from vitamin A deficiency

Open access
Kemp, Colin M., Jacobson, Samuel G., Borruat, François-Xavier, Chaitin, Michael H. · 1989 · Experimental Eye Research
Cited by 29

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Extended vitamin A deficiency in the cat led to an abnormal appearance in the tapetal fundus with the formation of a dark brown streak centered on the area centralis. At this time rod sensitivity, as measured by the b-wave of the electroretinogram, was reduced by more than two log units; the level of rod visual pigment was reduced by about 90% throughout the paracentral retinal region and was essentially absent from the area centralis. Following oral supplementation with vitamin A there was a rapid partial recovery of both rhodopsin levels and rod sensitivity. Further recovery continued over more than 18 days to levels that were not substantially below normal. This recovery was absent from the area centralis, in which measured visual pigment levels remained very low. In supplemented cats, the brown color in the fundus faded but there remained a small hyper-reflective zone at the area centralis. Morphological examination of the central retina in a supplemented cat showed an outer nuclear layer reduced to one or two rows in the small zone with low rhodopsin levels. Cone but not rod photoreceptors were present in this zone and they appeared to lack outer segments. During recovery, the increase in rod sensitivity was approximately linearly related to the recovery of rhodopsin levels. Thus, in these conditions reduction in sensitivity resulting from previous vitamin A deficiency was limited by the ability of the photoreceptors to absorb incident quanta. The time course of the recovery of rhodopsin and sensitivity suggests that at least two processes were involved. The faster of these may be the regeneration of rhodopsin from existing opsin molecules in the outer segments, while the slower may depend on the renewal of the outer segments themselves.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0014-4835(89)90075-4

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 29

Metadata

Authors
Kemp, C. M., Jacobson, S. G., Borruat, F.-X., & Chaitin, M. H.
Venue
Experimental Eye Research
Publisher
Elsevier BV
Published
1989-07
Volume
49
Issue
1
Pages
49-65
ISSN
0014-4835 (ISSN-L)
OpenAlex
W2155698095
Cited by
29
References
1
FWCI
0.37
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.