The DOI matches its Crossref record.
The polyoxyethylene/polyoxypropylene block co‐polymer Poloxamer‐407 selectively redirects intravenously injected microspheres to sinusoidal endothelial cells of rabbit bone marrow
Open accessAbstract
Small colloidal particulates (150 nm and below, in diameter) can be redirected specifically to the rabbit bone marrow following intravenous administration by coating their surface with the block co‐polymer poloxamer‐407, a non‐ionic surfactant. The coated colloids are sequestered by the sinusoidal endothelial cells of the bone marrow and are accumulated in dense bodies within these cells. The uptake of poloxamer‐4O7‐coated colloids by marrow eondothelial cells suggests that the steric repulsive barrier, imposed by the polyoxyethylene segment of the polymer, to particle‐cell interaction can apparently be overcome by a specific interaction mechanism(s) with the cell surface. Such a dramatic uptake cannot be achieved with other block co‐polymers of similar structure to poloxamer‐407. The application of the current model for the site‐specific targeting or drug carriers to bone marrow and the prevention of the adherence of metastases of tumours which selectively colonize the bone marrow endothelium is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Strategies in the design of nanoparticles for therapeutic applications
Petros, R. A., & DeSimone, J. M. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd2591 · Cited by 3,651
Opsonization, biodistribution, and pharmacokinetics of polymeric nanoparticles
OWENSIII, D., & PEPPAS, N. (2006) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2005.10.010 · Cited by 3,637
Nanomedicine: current status and future prospects
Moghimi, S. M., Hunter, A. C., & Murray, J. C. (2005) · The FASEB Journal · doi:10.1096/fj.04-2747rev · Cited by 2,029
Self-citationFormulation of functionalized PLGA-PEG Nanoparticles for in vivo targeted drug delivery
Cheng, J., Teply, B. A., Sherifi, I., Sung, J., Luther, G., Gu, F. X., Levy-Nissenbaum, E., Radovic-Moreno, A. F., Langer, R., & Farokhzad, O. C. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.047 · Cited by 1,273
Riess, J. G. (2001) · Chemical Reviews · doi:10.1021/cr970143c · Cited by 773
Metadata
- Authors
- Porter, C. J. H., Moghimi, S. M., Illum, L., & Davis, S. S.
- Venue
- FEBS Letters
- Publisher
- Wiley
- Published
- 1992-06-22
- Volume
- 305
- Issue
- 1
- Pages
- 62-66
- ISSN
- 0014-5793 (ISSN-L)
- 1873-3468
- OpenAlex
- W2001101070
- Cited by
- 173
- References
- 0
- FWCI
- 8.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The polyoxyethylene/polyoxypropylene block co‐polymer Poloxamer‐407 selectively redirects intravenously injected microspheres to sinusoidal endothelial cells of rabbit bone marrow. https://app.cochat.ai/papers/10.1016/0014-5793(92)80655-z
- The paper
- Porter, C. J. H., Moghimi, S. M., Illum, L., & Davis, S. S. (1992). The polyoxyethylene/polyoxypropylene block co‐polymer Poloxamer‐407 selectively redirects intravenously injected microspheres to sinusoidal endothelial cells of rabbit bone marrow. FEBS Letters. https://doi.org/10.1016/0014-5793(92)80655-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.