Mechanical characterization of skin—Finite deformations
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tregear, R. T. (1966) · Academic Press eBooks · Cited by 394
The Directional Effects of Skin
Ridge, M. D., & Wright, V. A. (1966) · Journal of Investigative Dermatology · doi:10.1038/jid.1966.54 · Cited by 122
Ridge, M. D., & Wright, V. A. (1966) · PubMed · Cited by 120
Viscoelastic properties of soft tissue by discrete model characterization
Jamison, C., Marangoni, R. D., & Glaser, A. A. (1968) · Journal of Biomechanics · doi:10.1016/0021-9290(68)90036-5 · Cited by 83
Determination of the tensile strength of the healing wound as a clinical test.
Sandblom, P., Petersen, P., & MUREN, A. (1953) · PubMed · Cited by 81
Viscoelastic Properties of Soft Tissue by Discrete Model Characterization
Jamison, C., Marangoni, R. D., & Glaser, A. A. (1968) · Journal of Engineering for Industry · doi:10.1115/1.3604620 · Cited by 21
Cited by
Auxetic metamaterials and structures: a review
Ren, X., Das, R., Tran, P., Ngo, T. D., & Xie, Y. M. (2018) · Smart Materials and Structures · doi:10.1088/1361-665x/aaa61c · Cited by 1,277
Constitutive equations for fibrous connective tissues
Lanir, Y. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90041-6 · Cited by 741
Martins, P. A. L. S., Natal Jorge, R. M., & Ferreira, A. J. M. (2006) · Strain · doi:10.1111/j.1475-1305.2006.00257.x · Cited by 521
Thill, C., Etches, J., Bond, I., Potter, K., & Weaver, P. (2008) · The Aeronautical Journal · doi:10.1017/s0001924000002062 · Cited by 487
Skin mechanical properties and modeling: A review
Joodaki, H., & Panzer, M. B. (2018) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411918759801 · Cited by 480
Negative Poisson's Ratio in Modern Functional Materials
Huang, C., & Chen, L. (2016) · Advanced Materials · doi:10.1002/adma.201601363 · Cited by 439
Lanir, Y. (1979) · Journal of Biomechanics · doi:10.1016/0021-9290(79)90027-7 · Cited by 396
Dandekar, K., Raju, B. I., & Srinivasan, M. A. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1613673 · Cited by 326
The materials science of collagen
Sherman, V. R., Yang, W., & Meyers, M. A. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.05.023 · Cited by 324
Functional Properties of Collagenous Tissues
Viidik, A. (1973) · International Review of Connective Tissue Research · doi:10.1016/b978-0-12-363706-2.50010-6 · Cited by 317
Viscoelastic constitutive law in large deformations
Pioletti, D. P., Rakotomanana, L. R., Benvenuti, J.-F., & Leyvraz, P.-F. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00077-3 · Cited by 288
Manufacturing, characteristics and applications of auxetic foams: A state-of-the-art review
Jiang, W., Ren, X., Wang, S. L., Zhang, X. G., Zhang, X. Y., Luo, C., Xie, Y. M., Scarpa, F., Alderson, A., & Evans, K. E. (2022) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2022.109733 · Cited by 284
Carneiro, V. H., Meireles, J., & Puga, H. (2013) · Materials Science-Poland · doi:10.2478/s13536-013-0140-6 · Cited by 221
Ligament material behavior is nonlinear, viscoelastic and rate-independent under shear loading
Weiss, J. A., Gardiner, J. C., & Bonifasi-Lista, C. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00041-6 · Cited by 210
“It was assumed that this stiffening behavior was due to the matrix strain energy, F1: After testing several forms for F1; a form introduced by Veronda and Westmann (Veronda and Westmann, 1970) was adopted: F1 ¼ C1½expðC2ð *I1 3ÞÞ 1 C1C2 2 ð *I2 3Þ: ð3Þ This strain energy is convex and exhibits physically reasonable be…”
MethodInfluentialPurslow, P. P., Wess, T. J., & Hukins, D. W. L. (1998) · Journal of Experimental Biology · doi:10.1242/jeb.201.1.135 · Cited by 208
Groves, R. B., Coulman, S. A., Birchall, J. C., & Evans, S. L. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.10.021 · Cited by 206
Mechanical characteristics of skin and underlying tissues in vivo
Bader, D. L., & Bowker, P. (1983) · Biomaterials · doi:10.1016/0142-9612(83)90033-9 · Cited by 202
Tactile Devices To Sense Touch on a Par with a Human Finger
Maheshwari, V., & Saraf, R. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200703693 · Cited by 193
Non-linear viscoelastic laws for soft biological tissues
Pioletti, D. P., & Rakotomanana, L. R. (2000) · European Journal of Mechanics - A/Solids · doi:10.1016/s0997-7538(00)00202-3 · Cited by 178
Modeling and estimation of the cardiac electromechanical activity
Sainte-Marie, J., Chapelle, D., Cimrman, R., & Sorine, M. (2006) · Computers & Structures · doi:10.1016/j.compstruc.2006.05.003 · Cited by 178
“Based on experimental results, the corresponding stress-strain laws are generally assumed to be of exponential type for Ep [ 17 ], and linear for Es [11].”
BackgroundSong, Y., Debski, R. E., Musahl, V., Thomas, M., & Woo, S. L.-Y. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00261-6 · Cited by 176
Auxetic mechanical metamaterials: from soft to stiff
Li, X., Peng, W., Wu, W., Xiong, J., & Lu, Y. (2023) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ace668 · Cited by 172
Auxetic mechanical metamaterials and their futuristic developments: A state-of-art review
Balan P, M., Mertens A, J., & Bahubalendruni, M. V. A. R. (2023) · Materials Today Communications · doi:10.1016/j.mtcomm.2022.105285 · Cited by 165
Soft network materials with isotropic negative Poisson's ratios over large strains
Liu, J., & Zhang, Y. (2018) · Soft Matter · doi:10.1039/c7sm02052j · Cited by 165
The mechanical behavior of skin: Structures and models for the finite element analysis
Benítez, J. M., & Montáns, F. J. (2017) · Computers & Structures · doi:10.1016/j.compstruc.2017.05.003 · Cited by 162
Age-related changes in the mechanical properties of the epimysium in skeletal muscles of rats
Gao, Y., Kostrominova, T. Y., Faulkner, J. A., & Wineman, A. S. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.021 · Cited by 149
Realistic force feedback for virtual reality based diagnostic surgery simulators
Vuskovic, V., Kauer, M., Szekely, G., & Reidy, M. (2002) · Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065) · doi:10.1109/robot.2000.844824 · Cited by 71
Estermann, S.-J., Förster-Streffleur, S., Hirtler, L., Streicher, J., Pahr, D. H., & Reisinger, A. (2021) · Annals of Anatomy - Anatomischer Anzeiger · doi:10.1016/j.aanat.2021.151717 · Cited by 27
Thermally damaged porcine skin is not a surrogate mechanical model of human skin
Gallagher, S., Kruger, U., Josyula, K., Rahul, Gong, A., Song, A., Sweet, R., Makled, B., Parsey, C., Norfleet, J., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-08551-z · Cited by 17
Metadata
- Authors
- Veronda, D. R., & Westmann, R. A.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1970-01
- Volume
- 3
- Issue
- 1
- Pages
- 111-124
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2072665320
- Cited by
- 555
- References
- 6
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.