The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
Abstract
Experimental determination of the elastic modulus and ultimate strength of human tibial trabecular bone as a function of metaphyseal location is presented. A 1 cm cubic matrix with planes parallel to the subchondral plate was defined on five fresh frozen cadaver tibias. Approximately 400, 7 mm X 10 mm cylindrical bone plugs were cut from the locations defined by the matrix and tested in uniaxial compressive stress at a strain rate of 0.1%S-1. Results of the study indicate that the trabecular bone properties vary as much as two orders of magnitude from one location to another. As might be predicted from Wolff's law, and noted by previous investigators, concentrations of strength arise from the medial and lateral metaphyseal cortices toward the major medial and lateral contact regions. These results may be valuable for improved analytical modeling and optimal prosthetic design.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Young’s modulus can vary by as much as 100-fold, and strength as much as fivefold, within a single epiphysis (88).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [88]
In the citing paper
“Young’s modulus can vary by as much as 100-fold, and strength as much as fivefold, within a single epiphysis (88).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [88]
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Bone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Koch, J. C. (1917) · American Journal of Anatomy · doi:10.1002/aja.1000210202 · Cited by 628
The mechanical properties of bone.
Evans, F. G. (1969) · PubMed · Cited by 562
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 418
Physical properties of trabecular bone
Galante, J. O., Rostoker, W., & Ray, R. D. (1970) · Calcified Tissue International · doi:10.1007/bf02017552 · Cited by 302
Mechanical Property Distributions in the Cancellous Bone of the Human Proximal Femur
Brown, T. D., & Ferguson, A. B. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990819 · Cited by 280
Performance of the tibial component in total knee replacement.
Bartel, D. L., Burstein, A. H., Santavicca, E. A., & Insall, J. N. (1982) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-198264070-00009 · Cited by 266
Tibiofemoral Contact Area-Determination and Implications
Kettelkamp, D. B., & Jacobs, A. W. (1972) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197254020-00013 · Cited by 247
The load-bearing area in the knee joint
Walker, P. S., & Hajek, J. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90030-9 · Cited by 231
Research works printed but not linked: 5
- Hayes, 1979, Correlations between stress and morphology in trabecular bone of the patella, Vol. 4, 88
- Kummer, 1966, Photoelastic studies on the functional structure of bone, Folia biotheor., 6, 31
- Meyer, 1867, Die Architektur der Spongiosa, Arch. Anat. Physiol., 47, 615
- Pauwels, 1948, Bedentung and Kausale Erklung der Spongiosaarchitektur in neuer Auffassung, Arztl. Wschr., 3, 379
- Wolff, 1870, Uber die innere Architektur der Knochen and ihre Bedeutung fur die Frame von Knockenwaschstum, Virchows Arch. path. Anat. Physiol., 50
Cited by
Sorted by citations
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“Young’s modulus can vary by as much as 100-fold, and strength as much as fivefold, within a single epiphysis (88).”
Bone tissue engineering: A review in bone biomimetics and drug delivery strategies
Porter, J. R., Ruckh, T. T., & Popat, K. C. (2009) · Biotechnology Progress · doi:10.1002/btpr.246 · Cited by 812
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 807
“For example, compressive modulus can vary 100-fold from one location to another within a single proximal tibia (19) (Figure 2), and strength can vary fivefold within the proximal femur (20).”
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 726
Evolution of bone transplantation: molecular, cellular and tissue strategies to engineer human bone
Yaszemski, M. J., Payne, R. G., Hayes, W. C., Langer, R., & Mikos, A. G. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85762-0 · Cited by 729
Metadata
- Authors
- Goldstein, S. A., Wilson, D. L., Sonstegard, D. A., & Matthews, L. S.
- Affiliations
- University of Michigan (US)
- ORCID
- Goldstein, Steven A.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1983-01
- Volume
- 16
- Issue
- 12
- Pages
- 965-969
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2038929699
- Cited by
- 292
- References
- 29
- Citations by year
- 2026: 7 · 2025: 3 · 2024: 10 · 2023: 6 · 2022: 8 · 2021: 9 · 2020: 10 · 2019: 5 · 2018: 8 · 2017: 6 · 2016: 10 · 2015: 8 · 2014: 10 · 2013: 10 · 2012: 6
- FWCI
- 13.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, tibia, elastic modulus, ultimate strength, uniaxial compression, bone mechanical properties, Wolff's law, cortical bone, bone plug, prosthesis design
- MeSH terms
- Aged, Biomechanical Phenomena, Cadaver, Female, Humans, Male, Middle Aged, Stress, Mechanical, Tibia
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review