Helical axes of passive knee joint motions
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,805
A Fortran package for generalized, cross-validatory spline smoothing and differentiation
Woltring, H. J. (1986) · Advances in Engineering Software (1978) · doi:10.1016/0141-1195(86)90098-7 · Cited by 1,055
Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.
Selvik, G. (1989) · PubMed · Cited by 702
Biomechanical analysis of knee flexion and extension
Smidt, G. L. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90040-7 · Cited by 511
Woltring, H. J., Huiskes, R., de Lange, A., & Veldpaus, F. E. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90293-3 · Cited by 468
Self-citationThe envelope of passive knee joint motion
Blankevoort, L., Huiskes, R., & de Lange, A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90280-1 · Cited by 376
Self-citationA three-dimensional mathematical model of the knee-joint
Wismans, J., Veldpaus, F., Janssen, J., Huson, A., & Struben, P. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90354-1 · Cited by 351
Soudan, K., Audekercke, R. V., & Martens, M. A. (1979) · Journal of Biomechanics · doi:10.1016/0021-9290(79)90006-x · Cited by 106
Analytical stereophotogrammetric determination of three-dimensional knee-joint geometry
Huiskes, R., Kremers, J., de Lange, A., Woltring, H. J., Selvik, G., & van Rens, T. J. G. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90011-9 · Cited by 92
Self-citationMeasurement errors in roentgen-stereophotogrammetric joint-motion analysis
de Lange, A., Huiskes, R., & Kauer, J. M. G. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90016-v · Cited by 85
Self-citation
Cited by
A Dynamic Optimization Solution for Vertical Jumping in Three Dimensions
ANDERSON, F. C., & PANDY, M. G. (1999) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255849908907988 · Cited by 573
The movement of the normal tibio-femoral joint
Freeman, M. A. R., & Pinskerova, V. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.006 · Cited by 532
“, 1988), helical axes (see, for example, Beggs, 1966; Shiavi et al., 1987; Blankevoort et al., 1990; Hart et al., 1991; Jonsson and Karrholm, 1994; Reinschmidt et al., 1999), or helical angles (Woltring, 1994).”
BackgroundArticular contact in a three-dimensional model of the knee
Blankevoort, L., Kuiper, J. H., Huiskes, R., & Grootenboer, H. J. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90019-j · Cited by 520
Self-citationThe Transepicondylar Axis Approximates the Optimal Flexion Axis of the Knee
Churchill, D. L., Incavo, S. J., Johnson, C. C., & Beynnon, B. D. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199811000-00016 · Cited by 497
Validation of a functional method for the estimation of hip joint centre location
Leardini, A., Cappozzo, A., Catani, F., Toksvig-Larsen, S., Petitto, A., Sforza, V., Cassanelli, G., & Giannini, S. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00148-1 · Cited by 415
“The former method (Cappozzo, 1984; Blankevoort et al., 1990; Cappozzo et al., 1995b; Shea et al., 1997) estimates the HJC as the pivot point of a 3-D relative movement between femur and pelvis recorded using photogrammetry.”
MethodFunctional calibration procedure for 3D knee joint angle description using inertial sensors
Favre, J., Aissaoui, R., Jolles, B. M., de Guise, J. A., & Aminian, K. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.025 · Cited by 301
Ligament-Bone Interaction in a Three-Dimensional Model of the Knee
Blankevoort, L., & Huiskes, R. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2894883 · Cited by 267
Self-citationHip joint center location from palpable bony landmarks—A cadaver study
Seidel, G. K., Marchinda, D. M., Dijkers, M., & Soutas-Little, R. W. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00149-x · Cited by 200
Injury and Repair of Ligaments and Tendons
Woo, S. L.-Y., Debski, R. E., Zeminski, J., Abramowitch, S. D., Chan Saw, M., & Fenwick, J. A. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.83 · Cited by 182
The components of passive knee movement are coupled to flexion angle
Wilson, D. R., Feikes, J. D., Zavatsky, A. B., & O'Connor, J. J. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00206-7 · Cited by 181
A new approach to measure functional stability of the knee based on changes in knee axis orientation
Grip, H., & Häger, C. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.12.015 · Cited by 46
“Although knee axes have been addressed in previous research, most studies are in-vitro or invasive (Blankevoort et al., 1990; Karrholm et al., 1994; van den Bogert et al., 2008) or investigate simple motion tasks e.”
BackgroundMethodResultInfluential
Metadata
- Authors
- Blankevoort, L., Huiskes, R., & de Lange, A.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1990-01
- Volume
- 23
- Issue
- 12
- Pages
- 1219-1229
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2117532839
- Cited by
- 194
- References
- 14
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.