The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Functional calibration procedure for 3D knee joint angle description using inertial sensors
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applied Linear Statistical Models
Ziegel, E. R., Neter, J., Wasserman, W., & Kutner, M. (1992) · Technometrics · doi:10.2307/1269588 · Cited by 9,907
Applied Linear Statistical Models.
Lorenz, F., Neter, J., Wasserman, W., & Kutner, M. H. (1986) · Journal of the American Statistical Association · doi:10.2307/2289108 · Cited by 5,565
Grood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,805
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Cappozzo, A., Catani, F., Della Croce, U., & Leardini, A. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)91394-t · Cited by 1,677
Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait
Kadaba, M. P., Ramakrishnan, H. K., Wootten, M. E., Gainey, J., Gorton, G., & Cochran, G. V. B. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070611 · Cited by 1,476
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Quaternions and Rotation Sequences
Kuipers, J. (2020) · Princeton University Press eBooks · doi:10.2307/j.ctvx5wc3k · Cited by 637
Gait analysis methods in rehabilitation
Baker, R. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-4 · Cited by 587
Cited by
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, T., Raisch, J., & Schauer, T. (2014) · Sensors · doi:10.3390/s140406891 · Cited by 867
Survey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion
Filippeschi, A., Schmitz, N., Miezal, M., Bleser, G., Ruffaldi, E., & Stricker, D. (2017) · Sensors · doi:10.3390/s17061257 · Cited by 361
Inertial Sensor-Based Gait Recognition: A Review
Sprager, S., & Juric, M. (2015) · Sensors · doi:10.3390/s150922089 · Cited by 347
Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics
Zhang, J.-T., Novak, A. C., Brouwer, B., & Li, Q. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/8/n63 · Cited by 314
Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., & Davies, J. (2018) · Sensors · doi:10.3390/s18030719 · Cited by 318
Metadata
- Authors
- Favre, J., Aissaoui, R., Jolles, B. M., de Guise, J. A., & Aminian, K.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2009-10
- Volume
- 42
- Issue
- 14
- Pages
- 2330-2335
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2101901432
- Cited by
- 301
- References
- 36
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functional calibration procedure for 3D knee joint angle description using inertial sensors. https://app.cochat.ai/papers/10.1016/j.jbiomech.2009.06.025
- The paper
- Favre, J., Aissaoui, R., Jolles, B. M., de Guise, J. A., & Aminian, K. (2009). Functional calibration procedure for 3D knee joint angle description using inertial sensors. Journal of Biomechanics. https://doi.org/10.1016/j.jbiomech.2009.06.025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.