The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
A review of the immobilization of enzymes in electropolymerized films
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Polyphenol permselective membranes are able to electropolymerize within an enzyme layer in a controllable manner, yielding a film with a thickness that is self-limiting (10–100 nm).”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [59]
Citations
Cites
Ferrocene-mediated enzyme electrode for amperometric determination of glucose
Cass, A. E. G., Davis, G. B., Francis, G. D., Hill, H. A. O., Aston, W. J., Higgins, I. J., Plotkin, E., Scott, L. D. L., & Turner, A. P. F. (1984) · Analytical Chemistry · doi:10.1021/ac00268a018 · Cited by 1,667
Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers
Foulds, N. C., & Lowe, C. R. (1988) · Analytical Chemistry · doi:10.1021/ac00173a008 · Cited by 613
Protein-modified electrodes. The glucose oxidase/polypyrrole system
Umaña, M., & Waller, J. (1986) · Analytical Chemistry · doi:10.1021/ac00127a018 · Cited by 588
Malitesta, C., Palmisano, F., Torsi, L., & Zambonin, P. G. (1990) · Analytical Chemistry · doi:10.1021/ac00223a016 · Cited by 570
Foulds, N. C., & Lowe, C. R. (1986) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19868201259 · Cited by 532
Sasso, S. V., Pierce, R. J., Walla, R., & Yacynych, A. M. (1990) · Analytical Chemistry · doi:10.1021/ac00210a004 · Cited by 343
Electrochemical immobilisation of enzymes
Bartlett, P. N., & Whitaker, R. G. (1987) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(87)85082-9 · Cited by 329
Mell, L. D., & Maloy, J. T. (1975) · Analytical Chemistry · doi:10.1021/ac60352a006 · Cited by 292
Rotating ring-disk enzyme electrode for surface catalysis studies
Shu, F. R., & Wilson, G. S. (1976) · Analytical Chemistry · doi:10.1021/ac50006a014 · Cited by 254
Electrochemical immobilisation of enzymes
Bartlett, P. N., & Whitaker, R. G. (1987) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(87)85081-7 · Cited by 248
Research works printed but not linked: 12
- Narasimham, 1986, Anal. Chem., 58, 2989
- Diaz, 1986, 1, 81
- Chandler, 1985, 10, 117
- Bentley, 1973, 7, 567
- Dicks, 1989, Ann. Biol. Clin., 47, 607
- Engasser, 1976, 1, 127
- Bartlett, 1991, Progr. React. Kinet., 16, 55
- J.M. Cooper and D. Bloor, Electroanalysis in press.
- Scott, 1983, J. Phys. B, 28, 2140
- Ohnuki, 1984, J. Electroanal. Chem., 158, 55
- Oshaka, 1984, Anal. Chem., 59, 1758
- Sasso, 1990, Anal. Chem., 62, 1111, 10.1021/ac00210a004 · DOI
Cited by
Sorted by citations
Application of conducting polymers to biosensors
Gerard, M. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00312-8 · Cited by 1,661
Potential of Different Enzyme Immobilization Strategies to Improve Enzyme Performance
Garcia‐Galan, C., Berenguer‐Murcia, Á., Fernández‐Lafuente, R., & Rodrigues, R. C. (2011) · Advanced Synthesis & Catalysis · doi:10.1002/adsc.201100534 · Cited by 1,617
Bobacka, J., Ivaska, A. U., & Lewenstam, A. (2008) · Chemical Reviews · doi:10.1021/cr068100w · Cited by 980
Electrochemistry of Poly(3,4‐alkylenedioxythiophene) Derivatives
Groenendaal, L., Zotti, G., Aubert, P., Waybright, S. M., & Reynolds, J. R. (2003) · Advanced Materials · doi:10.1002/adma.200300376 · Cited by 943
Multifunctional 3D nanoarchitectures for energy storage and conversion
Rolison, D. R., Long, J. W., Lytle, J. C., Fischer, A. E., Rhodes, C. P., McEvoy, T. M., Bourg, M., & Lubers, A. M. (2008) · Chemical Society Reviews · doi:10.1039/b801151f · Cited by 822
Metadata
- Authors
- Barlett, P. N., & Cooper, J. M.
- Affiliations
- University of Southampton (GB)
- University of Glasgow (GB)
- ORCID
- Cooper, J.M.
- Venue
- Journal of Electroanalytical Chemistry
- Publisher
- Elsevier BV
- Published
- 1993-12
- Volume
- 362
- Issue
- 1-2
- Pages
- 1-12
- ISSN
- 1572-6657 (ISSN-L)
- OpenAlex
- W1987410104
- Cited by
- 472
- References
- 72
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 5 · 2023: 5 · 2022: 3 · 2021: 3 · 2020: 6 · 2019: 9 · 2018: 9 · 2017: 6 · 2016: 12 · 2015: 8 · 2014: 16 · 2013: 22 · 2012: 11
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Electroanalytical Chemistry (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Enzyme Catalysis and Immobilization
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Keywords
- enzyme immobilization, electropolymerization, conducting polymer films, electrode surface
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review