Effect of in vivo crown margin discrepancies on periodontal health
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Numerous reports have suggested a relationship between marginal adaptation of dental castings and periodontal tissue health, and this study examined this relationship quantitatively. Forty-two crown restorations in 29 randomly selected patients were selected for this study using three criteria. (1) The crowns were placed at the University of North Carolina School of Dentistry; (2) the crowns were in service for a minimum of 4 years; and (3) the crown margins were within the intracrevicular crevice (subgingival). Replica impressions of the facial margins of specific crowns were made with a vinyl polysiloxane impression material, and poured casts were prepared for scanning electron micrograph evaluation. Marginal discrepancy measurements were identified on each micrograph at 10 equally spaced locations along the margin and averaged for each specimen. Periodontal indices of pocket depths, crevicular fluid volume, and gingival index were accumulated for clinical measurements. Pearson correlation and Bonferroni adjusted probability tests were performed, but no significant correlation was found between marginal discrepancy (0.16 +/- 0.13 mm) and pocket depth (2.4 +/- 0.9 mm). However, a strong correlation (p less than 0.001) existed between marginal discrepancy and gingival index (2 +/- 0.8) and between marginal discrepancies and crevicular fluid volume (49.9 +/- 31.1). These results established that a significant quantitative relationship existed between the marginal discrepancy and periodontal tissue inflammation for subgingivally located crown margins.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal Condition
Silness, J., & Löe, H. (1964) · Acta Odontologica Scandinavica · doi:10.3109/00016356408993968 · Cited by 7,932
Bacterial leakage around dental restorations: its effect on the dental pulp
Bergenholtz, G., Cox, C. F., Loesche, W. J., & Syed, S. A. (1982) · Journal of Oral Pathology & Medicine · doi:10.1111/j.1600-0714.1982.tb00188.x · Cited by 459
Marginal fit of gold inlay castings
Christensen, G. J. (1966) · The Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(66)90082-5 · Cited by 428
Lang, N. P., Kiel, R. A., & Anderhalden, K. (1983) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1983.tb01295.x · Cited by 399
VALDERHAUGW, J., & BIRKELAND, J. M. (1976) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.1976.tb00949.x · Cited by 204
Effect of bacterial products on inflammatory reactions in the dental pulp
BERGEMHOLTZ, G. (1977) · European Journal of Oral Sciences · doi:10.1111/j.1600-0722.1977.tb00542.x · Cited by 180
Silness, J. (1970) · Journal of Periodontal Research · doi:10.1111/j.1600-0765.1970.tb00721.x · Cited by 163
Relationship of crown margin placement to gingival inflammation
Richter, W., & Ueno, H. (1973) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(73)90050-4 · Cited by 124
Valderhaug, J. (1980) · PubMed · Cited by 119
Relief of resistance of cement of full cast crowns
Fusayama, T., Ide, K., & Hosoda, H. (1964) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(64)90124-6 · Cited by 113
Research works printed but not linked: 2
- Strub, 1978, Parodontalzustand bei Patienten mit kronen und bruckenprothetischem Ersatz, SSO: Schweizerische Monattsschrift Fur Zahnheilkunde, 88, 569
- Golub, 1974, An intracrevicular technique for monitoring gingival crevicular fluid (GCF) flow [Abstract], J Dent Res, 53, 175
Cited by
Marginal adaptation of ceramic crowns: A systematic review
Contrepois, M., Soenen, A., Bartala, M., & Laviole, O. (2013) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2013.08.003 · Cited by 440
Reich, S., Wichmann, M. G., Nkenke, E., & Proeschel, P. (2005) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.2004.00197.x · Cited by 364
Nawafleh, N. A., Mack, F., Evans, J., Mackay, J., & Hatamleh, M. M. (2013) · Journal of Prosthodontics · doi:10.1111/jopr.12006 · Cited by 346
Groten, M., Axmann, D., Pröbster, L., & Weber, H. (2000) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(00)70087-4 · Cited by 308
Papadiochou, S., & Pissiotis, A. L. (2018) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2017.07.001 · Cited by 304
Fit of zirconia fixed partial denture: a systematic review
ABDUO, J., LYONS, K., & SWAIN, M. (2010) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2010.02113.x · Cited by 249
Mously, H. A., Finkelman, M., Zandparsa, R., & Hirayama, H. (2014) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2014.03.017 · Cited by 230
The effect of cement thickness on the fracture strength of all‐ceramic crowns
Tuntiprawon, M., & Wilson, P. R. (1995) · Australian Dental Journal · doi:10.1111/j.1834-7819.1995.tb05607.x · Cited by 232
May, L. G., Kelly, J. R., Bottino, M. A., & Hill, T. (2012) · Dental Materials · doi:10.1016/j.dental.2012.04.033 · Cited by 206
“Only one clinical study of subgingival marginal miss-fits of crowns appears to exist with the only negative outcome being a mild gingivitis response; finding correlations between marginal gap and gingival index and crevicular fluid volume, but none with pocket depth [5].”
BackgroundAnti-infective treatment of peri-implant mucositis: a randomised controlled clinical trial
Heitz-Mayfield, L. J. A., Salvi, G. E., Botticelli, D., Mombelli, A., Faddy, M., Lang, N. P., & On Behalf of the Implant Complication Research Group (ICRG) (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2010.02078.x · Cited by 185
“considering the association between subgingival restoration margins at teeth and periodontal inflammation and loss of attachment (Strub & Belser 1978; Lang et al. 1983; Felton et al. 1991; Schätzle et al. 2001).”
BackgroundResultGonzalo, E., Suárez, M. J., Serrano, B., & Lozano, J. F. L. (2009) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(09)60198-0 · Cited by 179
Evaluation of marginal and internal fit of ceramic crown copings
Colpani, J. T., Borba, M., & Bona, Á. D. (2012) · Dental Materials · doi:10.1016/j.dental.2012.10.012 · Cited by 162
“The presence of a marginal gap can lead to dissolution of the luting agent, creating an area for biofilm development that may cause caries and periodontal diseases [1–3].”
BackgroundPeriodontal tissue responses after insertion of artificial crowns and fixed partial dentures
Knoernschild, K. L., & Campbell, S. D. (2000) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2000.110262 · Cited by 162
Clinical outcomes of three different crown systems with CAD/CAM technology
Batson, E. R., Cooper, L. F., Duqum, I., & Mendonça, G. (2014) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2014.05.002 · Cited by 179
Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns
Kale, E., Şeker, E., Yılmaz, B., & Özçelik, T. B. (2016) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2016.05.006 · Cited by 155
“Excessive discrepancy at the crown margins may promote microleakage through increased cement dissolution,(28) which may lead to secondary caries and inflammation of dental pulp,(29,30) an increase in plaque accumulation,(31) and a predisposition to periodontal disease.(32,33) The accuracy of fit may depend on the diff…”
Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses
Att, W., Komine, F., Gerds, T. A., & Strub, J. R. (2009) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(09)60047-0 · Cited by 154
Trueness and precision of 3D-printed versus milled monolithic zirconia crowns: An in vitro study
Lerner, H., Nagy, K., Pranno, N., Zarone, F., Admakin, O. I., & Mangano, F. G. (2021) · Journal of Dentistry · doi:10.1016/j.jdent.2021.103792 · Cited by 153
Adaptation of all-ceramic fixed partial dentures
Borba, M., Cesar, P. F., Griggs, J. A., & Bona, Á. D. (2011) · Dental Materials · doi:10.1016/j.dental.2011.08.004 · Cited by 193
“Felton et al [10] investigated the in vivo the relationship between marginal adaptation and periodontal tissue health and noticed that an increase in the marginal discrepancy resulted in an increase in gingival inflammation.”
Tan, P. L., Gratton, D. G., Diaz‐Arnold, A. M., & Holmes, D. C. (2008) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2008.00302.x · Cited by 147
Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems
Balkaya, M. C., Cinar, A., & Pamuk, S. (2005) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2005.02.003 · Cited by 146
Effect of Sintering on the Marginal and Internal Fit of CAD/CAM-fabricated Zirconia Frameworks
Kunii, J., HOTTA, Y., Tamaki, Y., Ozawa, A., Kobayashi, Y., Fujishima, A., Miyazaki, T., & Fujiwara, T. (2007) · Dental Materials Journal · doi:10.4012/dmj.26.820 · Cited by 145
Kohorst, P., Brinkmann, H., Li, J., Borchers, L., & Stiesch, M. (2009) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.2009.00622.x · Cited by 168
Souza, R. O. D. A. E., Özcan, M., Pavanelli, C. A., Buso, L., Lombardo, G. H. L., Michida, S. M. D. A., Mesquita, A. M. M., & Bottıno, M. A. (2011) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2011.00793.x · Cited by 139
Euán, R., Figueras-Álvarez, Ò., Cabratosa‐Termes, J., & Oliver-Parra, R. (2014) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2013.10.012 · Cited by 137
Revilla‐León, M., Methani, M. M., Morton, D., & Zandinejad, A. (2020) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2019.09.018 · Cited by 136
Sakornwimon, N., & Leevailoj, C. (2017) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2016.10.019 · Cited by 122
“Significant periodontal inflammation was found to occur in crowns with marginal discrepancies from 250 to 430 mm.(16) Nevertheless, the most appropriate, clinically acceptable value for maximum marginal discrepancy has not been reached.”
BackgroundDemir, N., Öztürk, A. N., & Malkoç, M. A. (2014) · European Journal of Dentistry · doi:10.4103/1305-7456.143612 · Cited by 121
“,[14] the perpendicular measurement from the internal surface of the margin of the crown or casting to the outermost edge of the finish line of the tooth margin is termed as the MG.”
BackgroundVigolo, P., & Fonzi, F. (2008) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2008.00366.x · Cited by 135
In vitro evaluation of the "replica technique" in the measurement of the fit of Procera crowns.
Rahme, H. Y., Tehini, G. E., Adib, S. M., Ardo, A. S., & Rifai, K. T. (2008) · PubMed · Cited by 118
Fit of single tooth zirconia copings: comparison between various manufacturing processes
Grenade, C., Mainjot, A. K. J., & Vanheusden, A. J. (2011) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(11)60040-1 · Cited by 138
Keul, C., Stawarczyk, B., Erdelt, K. J., Beuer, F., Edelhoff, D., & Güth, J. (2014) · Dental Materials · doi:10.1016/j.dental.2014.01.006 · Cited by 109
“Inferior marginal fit can lead to washout of the cement and altogether to a negative impact of the adjacent tissues [25].”
BackgroundRiccitiello, F., Amato, M., Leone, R., Spagnuolo, G., & Sorrentino, R. (2018) · The Open Dentistry Journal · doi:10.2174/1874210601812010160 · Cited by 106
Dental prostheses and tooth‐related factors
Ercoli, C., & Caton, J. G. (2018) · Journal of Periodontology · doi:10.1002/jper.16-0569 · Cited by 105
Clinical performance and failures of zirconia-based fixed partial dentures: a review literature
Triwatana, P., Nagaviroj, N., & Tulapornchai, C. (2012) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2012.4.2.76 · Cited by 105
“Excessive marginal gap width could lead to cement leakage, secondary caries, periodontal and endodontic complications which could compromise the survival of a restoration or an abutment tooth.(35) Currently, computer-aided design and computer-aided machine systems (CAD-CAM) are generally available for processing of al…”
BackgroundDifferent CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy
Kohorst, P., Junghanns, J., Dittmer, M. P., Borchers, L., & Stiesch, M. (2010) · Clinical Oral Investigations · doi:10.1007/s00784-010-0415-9 · Cited by 119
Gaintantzopoulou, M. D., & El-Damanhoury, H. M. (2016) · Operative Dentistry · doi:10.2341/15-146-l · Cited by 103
Lulic, M., Brägger, U., Lang, N. P., Zwahlen, M., & Salvi, G. E. (2007) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01438.x · Cited by 100
Biofilm and Dental Biomaterials
Øilo, M., & Bakken, V. (2015) · Materials · doi:10.3390/ma8062887 · Cited by 123
“The border between the tooth and the restorations will always be problematic, since it is virtually impossible to make restorations with perfect adaptations all the way around [42,43].”
BackgroundGhoul, W. E., Özcan, M., Ounsi, H., Tohmé, H., & Salameh, Z. A. (2019) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2018.10.024 · Cited by 100
Reich, S., Uhlen, S., Gozdowski, S., & Lohbauer, U. (2010) · Clinical Oral Investigations · doi:10.1007/s00784-010-0414-x · Cited by 93
“A good marginal accuracy tends to reduce recurrent caries and the risk of a restoration-related periodontal inflammation [ 10 , 11].”
BackgroundHosseini, M., Worsaae, N., Schiødt, M., & Gotfredsen, K. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02514.x · Cited by 100
Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses
Kohorst, P., Brinkmann, H., Dittmer, M. P., Borchers, L., & Stiesch, M. (2010) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2009.02053.x · Cited by 91
An, S., Kim, S., Choi, H., Lee, J. H., & Moon, H. (2014) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2013.12.024 · Cited by 113
Computer-assisted milling of dental restorations using a new CAD/CAM data acquisition system
Willer, J., Roßbach, A., & Weber, H. (1998) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(98)70136-2 · Cited by 101
Marginal Fit Comparison of CAD/CAM Crowns Milled from Two Different Materials
Azarbal, A., Azarbal, M., Engelmeier, R. L., & Kunkel, T. C. (2017) · Journal of Prosthodontics · doi:10.1111/jopr.12683 · Cited by 101
“Some of the reported complications resulting from poor marginal fit are dissolution of the luting agent (2), microleakage (3, 6), caries (2, 3, and 6), hypersensitivity and periodontal inflammation (5, 7, 57-59)”
Politano, G., MEERBEEK, B. V., & Peumans, M. (2018) · PubMed · doi:10.3290/j.jad.a41630 · Cited by 87
Fit, Precision, and Trueness of 3D-Printed Zirconia Crowns Compared to Milled Counterparts
Abualsaud, R., & Alalawi, H. (2022) · Dentistry Journal · doi:10.3390/dj10110215 · Cited by 87
“The marginal mismatch at the restoration/tooth interface can cause the cement to dissolve [24,25], allow microleakage, jeopardize the pupal health [22], initiate secondary caries [23,24], as well as promote periodontal inflammation [24,26].”
BackgroundFonseca, J. C., Henriques, G. E. P., Sobrinho, L. C., & de Góes, M. F. (2003) · Dental Materials · doi:10.1016/s0109-5641(03)00014-9 · Cited by 87
“As a visibly detected problem that could be affected by distortion, increased marginal discrepancy is treated as the most clinically relevant issue [16] with repercussion on the cement margin, increased gingival inflammation and risk of secondary caries [17].”
BackgroundLüchtenborg, J., Willems, E., Zhang, F., Wesemann, C., Weiß, F., Nold, J., Sun, J., Sandra, F., Bai, J., Reverón, H., et al. (2022) · Dental Materials · doi:10.1016/j.dental.2022.06.026 · Cited by 86
Clinical fit of four‐unit zirconia posterior fixed dental prostheses
Reich, S., Kappe, K., Teschner, H., & Schmitt, J. (2008) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.2008.00580.x · Cited by 86
“Marginal misfit can lead to recurrent caries, periodontal disease (9, 10), and optical drawbacks.”
BackgroundEffect of posterior crown margin placement on gingival health
Reitemeier, B., Hänsel, K., Walter, M. H., Kastner, C., & Toutenburg, H. (2002) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2002.121585 · Cited by 83
Additive Manufacturing of Dental Ceramics: A Systematic Review and Meta‐Analysis
Hamad, K. Q. A., Al‐Rashdan, B. A., Ayyad, J. Q., Omrani, L. M. A., Sharoh, A. M., Nimri, A. M. A., & Al‐Kaff, F. T. (2022) · Journal of Prosthodontics · doi:10.1111/jopr.13553 · Cited by 83
Vojdani, M., Torabi, K., Farjood, E., & Khaledi, A. A. R. (2013) · PubMed Central · Cited by 83
The marginal fit of E.max Press and E.max CAD lithium disilicate restorations: A critical review
Mounajjed, R., Layton, D., & Azar, B. (2016) · Dental Materials Journal · doi:10.4012/dmj.2016-008 · Cited by 81
Clinical marginal and internal gaps of zirconia all-ceramic crowns
Kokubo, Y., Tsumita, M., Kano, T., Sakurai, S., & Fukushima, S. (2010) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2010.09.001 · Cited by 80
“The large gap may cause cement solubility and result in plaque accumulation, marginal leakage, second caries, and eventually crown failure [6,7].”
BackgroundStresses and distortions within zirconia-fixed dental prostheses due to the veneering process
Dittmer, M. P., Borchers, L., Stiesch, M., & Kohorst, P. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.04.025 · Cited by 80
Marginal gap and internal fit of 3D printed versus milled monolithic zirconia crowns
Refaie, A., Fouda, A. M., Bourauel, C. P., & Singer, L. (2023) · BMC Oral Health · doi:10.1186/s12903-023-03184-8 · Cited by 79
“Poor marginal adaptation can lead to plaque accumulation, microleakage, recurrent caries, and periodontal disease [10].”
BackgroundWang, W., & Sun, J. (2020) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2020.02.032 · Cited by 78
Ercoli, C., Tarnow, D., Poggio, C. E., Tsigarida, A., Ferrari, M., Caton, J. G., & Chochlidakis, K. (2021) · Journal of Prosthodontics · doi:10.1111/jopr.13292 · Cited by 58
Paniz, G., Nart, J., Gobbato, L., Chierico, A., Lops, D., & Michalakis, K. (2016) · Clinical Oral Investigations · doi:10.1007/s00784-015-1616-z · Cited by 67
Dental prostheses and tooth‐related factors
Ercoli, C., & Caton, J. G. (2018) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12950 · Cited by 67
Marginal accuracy and internal fit of machine-milled and cast titanium crowns
Han, H.-S., Yang, H.-S., Lim, H., & Park, Y.-J. (2011) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(11)60120-0 · Cited by 67
Komine, F., Gerds, T. A., Witkowski, S., & Strub, J. R. (2005) · Acta Odontologica Scandinavica · doi:10.1080/00016350500264313 · Cited by 66
Two imaging techniques for 3D quantification of pre-cementation space for CAD/CAM crowns
Rungruanganunt, P., Kelly, J. R., & Adams, D. J. (2010) · Journal of Dentistry · doi:10.1016/j.jdent.2010.08.015 · Cited by 62
Juntavee, N., Juntavee, A., & Plongniras, P. (2018) · International Journal of Nanomedicine · doi:10.2147/ijn.s165080 · Cited by 62
“Improper marginal adaptation of dental restoration induces bacterial deposition on the plaque, which initiates periodontal disease and decay, leading to the failure of restoration.(2) Underprivileged marginal fit of CAD– CAM restoration often causes decay around the finishing line of restoration, which is generally pl…”
BackgroundInterdisciplinary interface between fixed prosthodontics and periodontics
Abduo, J., & Lyons, K. M. (2017) · Periodontology 2000 · doi:10.1111/prd.12189 · Cited by 55
“Although several laboratory studies have shown such features to be important, a large proportion of the clinical complications in fixed prosthodontics have been biological in nature, such as caries and periodontal disease (38, 48, 62, 134).”
Boeckler, A. F., Stadler, A., & Setz, J. M. (2005) · The Journal of Contemporary Dental Practice · doi:10.5005/jcdp-6-4-26 · Cited by 68
“Thus, for clinical evaluation of fit, it can be assumed overextensions are safer to detect than gaps.(4-8) White et al.”
BackgroundChatzistavrou, X., Tsigkou, O., Amin, H. D., Paraskevopoulos, K., Salih, V. M., & Boccaccini, A. R. (2012) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2012.04.037 · Cited by 60
Marginal Accuracy and Internal Fit of 3-D Printing Laser-Sintered Co-Cr Alloy Copings
Kim, M., Choi, Y., Kim, S., Heo, S., & Koak, J. (2017) · Materials · doi:10.3390/ma10010093 · Cited by 60
“Subgingival marginal discrepancies in implant-supported restorations are related to changes in the ecologic environment, that may contribute to the occurrence of peri-implantitis or to bone loss in the marginal portion of the implant [24,27].”
BackgroundEvaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology
Borba, M., Miranda, W. G., Cesar, P. F., Griggs, J. A., & Bona, Á. D. (2013) · Brazilian Oral Research · doi:10.1590/s1806-83242013000500003 · Cited by 59
Fit of anterior restorations made of 3D-printed and milled zirconia: An in-vitro study
Rues, S., Zehender, N., Zenthöfer, A., Bömicke, W., Herpel, C., Ilani, A., Erber, R., Roser, C. J., Lux, C. J., Rammelsberg, P., et al. (2023) · Journal of Dentistry · doi:10.1016/j.jdent.2023.104415 · Cited by 58
Gervais, M. J., & Wilson, P. R. (2007) · PubMed · Cited by 76
Gingival Displacement for Impression Making in Fixed Prosthodontics
Baba, N. Z., Goodacre, C. J., Jekki, R., & Won, J. (2013) · Dental Clinics of North America · doi:10.1016/j.cden.2013.09.002 · Cited by 57
Hamad, K. Q. A., Al‐Rashdan, B. A., Omari, W. M. A., & Baba, N. Z. (2018) · Journal of Prosthodontics · doi:10.1111/jopr.12961 · Cited by 57
Full-arch prostheses from translucent zirconia: Accuracy of fit
Sachs, C., Groesser, J., Stadelmann, M., Schweiger, J., Erdelt, K. J., & Beuer, F. (2014) · Dental Materials · doi:10.1016/j.dental.2014.05.001 · Cited by 65
“[19] Felton DA, Kanoy BE, Bayne SC, Wirthman GP.”
BackgroundBiscaro, L., Bonfiglioli, R., Soattin, M., & Vigolo, P. (2012) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2012.00907.x · Cited by 66
Mostafa, N. Z., Ruse, N. D., Ford, N. L., Carvalho, R. M., & Wyatt, C. C. L. (2017) · Journal of Prosthodontics · doi:10.1111/jopr.12656 · Cited by 61
Prevalence of colibacillosis in chickens in greater Mymensingh district of Bangladesh
Matin, M. A., Islam, M. A., & Khatun, M. M. (2017) · Veterinary World · doi:10.14202/vetworld.2017.29-33 · Cited by 53
Marginal and internal adaptation of milled cobalt-chromium copings
Kane, L., Chronaios, D., Sierraalta, M., & George, F. M. (2015) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.04.020 · Cited by 52
Hosseini, M., Worsaae, N., Schiødt, M., & Gotfredsen, K. (2011) · PubMed · Cited by 51
Additive manufacturing of dental ceramics in prosthodontics: The status quo and the future
Zhu, H., Jiang, J., Wang, Y., Wang, S., He, Y., & He, F. (2024) · Journal of Prosthodontic Research · doi:10.2186/jpr.jpr_d_23_00119 · Cited by 53
Ahmed, W. M., Abdallah, M., McCullagh, A., Wyatt, C. C. L., Troczynski, T., & Carvalho, R. M. (2019) · Journal of Prosthodontics · doi:10.1111/jopr.13021 · Cited by 50
Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems
Ha, S.-J., & Cho, J.-H. (2016) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2016.8.6.439 · Cited by 49
Jahangiri, L., Wahlers, C., Hittelman, E. L., & Matheson, P. (2005) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2004.11.007 · Cited by 49
Acar, Ö., Erkut, S., Özçelik, T. B., Özdemir, E., & Akçil, M. (2013) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2013.08.009 · Cited by 48
Morsy, N., Kateb, M. E., Azer, A. S., & Fathalla, S. (2021) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2021.08.025 · Cited by 53
Effect of digital impressions and production protocols on the adaptation of zirconia copings
Kocaağaoğlu, H., Kılınç, H. İ., & Albayrak, H. (2016) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2016.06.004 · Cited by 57
Effect of different retraction and impression techniques on the marginal fit of crowns
Wöstmann, B., Rehmann, P., Trost, D., & Balkenhol, M. (2008) · Journal of Dentistry · doi:10.1016/j.jdent.2008.03.013 · Cited by 64
“The importance of a good fitting restoration to prevent periodontal damage and caries is unquestionable, though the size of the clinically acceptable misfit is still unclear.(17,18) Nevertheless, there is evidence that the precision achievable in laboratory investigations is not reflected in patients.”
BackgroundA systematic review on the accuracy of zirconia crowns and fixed dental prostheses
Svanborg, P. (2020) · Biomaterial Investigations in Dentistry · doi:10.1080/26415275.2019.1708202 · Cited by 46
“Also, crowns with the poor marginal fit on subgingivally placed margins may increase bacterial retention and cause gingival inflammation [2].”
BackgroundNejatidanesh, F., Shakibamehr, A. H., & Savabi, O. (2015) · Implant Dentistry · doi:10.1097/id.0000000000000346 · Cited by 50
“The consequence of cement dissolution is increase in gingival inflammation and periodontal or periimplant disease because of changes in the subgingival microflora and plaque retention.(17,20) In addition, marginal fit”
BackgroundKauling, A. E. C., Güth, J., Erdelt, K. J., Edelhoff, D., & Keul, C. (2019) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2019.09.003 · Cited by 51
Kim, J., Cho, B., Lee, J.-H., Kwon, S.-J., Yi, Y., Shin, Y., Roh, B., & Seo, D. (2014) · Acta Odontologica Scandinavica · doi:10.3109/00016357.2014.956145 · Cited by 45
“Poor marginal fit can exacerbate degradation of luting cements in the oral environment, resulting in microleakage, recurrent caries, periodontal disease and marginal discoloration [10,11].”
BackgroundIn vitro evaluation of the internal and marginal misfit of CAD/CAM zirconia copings
Lins, L., Pinto, V. B. B., Queiroz, C. S., & Canabarro, A. (2014) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2014.09.010 · Cited by 49
Human epithelial tissue culture study on restorative materials
Forster, A., Ungvári, K., Györgyey, Á., Kukovecz, Á., Turzó, K., & Nagy, K. (2013) · Journal of Dentistry · doi:10.1016/j.jdent.2013.11.008 · Cited by 44
Evaluation of the fit of metal ceramic restorations fabricated with a pre-sintered soft alloy
Park, J.-K., Kim, H.-Y., Kim, W., & Kim, J. (2016) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2016.03.024 · Cited by 44
Padrós, R., Giner, L., Herrero‐Climent, M., Falcão, C. A. M., Ríos-Santos, J., & Gil, F. J. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17124276 · Cited by 43
Iatrogenic Damage to Periodontium by Restorative Treatment Procedures: An Overview
Sirajuddin, S., Narasappa, K. M., Gundapaneni, V., Chungkham, S., & Walikar, A. S. (2015) · The Open Dentistry Journal · doi:10.2174/1874210601509010217 · Cited by 49
“Declared none.”
Alani, A., Kelleher, M., Hemmings, K. W., Saunders, M., Hunter, M. J., Barclay, S. C., Ashley, M. P., Djemal, S., Bishop, K., Darbar, U. R., et al. (2015) · BDJ · doi:10.1038/sj.bdj.2015.345 · Cited by 50
Influence of finish line design on marginal adaptation of electroformed metal-ceramic crowns
Shiratsuchi, H., Komine, F., Kakehashi, Y., & Matsumura, H. (2006) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2006.01.009 · Cited by 43
The effect of fixed partial dentures on periodontal status of abutment teeth
Alsinaidi, A. A., & Preethanath, R. S. (2013) · The Saudi Journal for Dental Research · doi:10.1016/j.ksujds.2013.11.001 · Cited by 49
Metadata
- Authors
- Felton, D. A., Kanoy, B. E., Bayne, S. C., & Wirthman, G. P.
- Affiliations
- University of North Carolina at Chapel Hill (US)
- Corresponding author
- Felton, D.A.
- ORCID
- Bayne, S.C.
- Venue
- The Journal of Prosthetic Dentistry
- Publisher
- Elsevier BV
- Published
- 1991-03
- Volume
- 65
- Issue
- 3
- Pages
- 357-364
- ISSN
- 0022-3913 (ISSN-L)
- OpenAlex
- W2045628652
- Semantic Scholar
- 91a4d384640f557cf2e040cd014055d338bf2ecd
- Cited by
- 430
- References
- 26
- Citations by year
- 2026: 16 · 2025: 23 · 2024: 23 · 2023: 27 · 2022: 19 · 2021: 32 · 2020: 29 · 2019: 19 · 2018: 29 · 2017: 23 · 2016: 19 · 2015: 31 · 2014: 18 · 2013: 11 · 2012: 11
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Prosthetic Dentistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Center for Research Resources (RR05333)
- Topics
- Health Sciences › Dentistry › General Dentistry › Dental materials and restorations
- Health Sciences › Dentistry › Periodontics › Oral microbiology and periodontitis research
- Health Sciences › Dentistry › Oral Surgery › Endodontics and Root Canal Treatments
- Keywords
- marginal adaptation, dental crowns, periodontal health, gingival index, probing depth, subgingival margin, periodontal inflammation, scanning electron microscopy
- MeSH terms
- Adult, Aged, Crowns, Dental Cavity Preparation, Denture Design, Denture, Partial, Fixed, Gingival Crevicular Fluid, Humans, Microscopy, Electron, Scanning, Middle Aged, Periodontal Diseases, Periodontal Index, Retrospective Studies, Surface Properties, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.