CoChat

An In Vitro Comparison of Vertical Marginal Gaps of CAD/CAM Titanium and Conventional Cast Restorations

Tan, Philip L., Gratton, David G., Diaz‐Arnold, Ana M., Holmes, David C. · 2008 · Journal of Prosthodontics
Cited by 147

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Purpose: To determine if there was a significant difference between the vertical marginal openings of cast restorations, computer‐aided design, and computer‐aided machining restorations. Materials and Methods: Ten working dies were created from a single master die and used to fabricate ten restorations in each of the following groups: computer‐aided design/computer‐assisted machining (CAD/CAM), WAX/CAM, and WAX/CAST. The CAD/CAM titanium restorations were fabricated using the scanning and crown design modules of the KaVo Everest system. The WAX/CAM titanium restorations were fabricated using the double scan technique with the KaVo Everest system. The WAX/CAST high noble copings were fabricated using the conventional lost wax casting technique. The restorations were seated on the master die, and high‐resolution digital photographs were made of the marginal area on all four sides. The vertical marginal opening was then measured using a calibrated digital software program. One‐way ANOVA and Tukey's post hoc tests were used to determine the presence of statistically significant differences. Results: The vertical margin openings were CAD/CAM: 79.43 ± 25.46 μm; WAX/CAM: 73.12 ± 24.15 μm; WAX/CAST: 23.91 ± 9.80 μm. There was a statistically significant difference between the WAX/CAST group and the remaining groups. Conclusions: There was no difference between the vertical marginal gaps of the CAD/CAM and WAX/CAM. The WAX/CAST technique resulted in smaller vertical marginal gaps than either CAD/CAM or WAX/CAM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1532-849x.2008.00302.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 147

Metadata

Authors
Tan, P. L., Gratton, D. G., Diaz‐Arnold, A. M., & Holmes, D. C.
Venue
Journal of Prosthodontics
Publisher
Wiley
Published
2008-07
Volume
17
Issue
5
Pages
378-383
ISSN
  • 1059-941X (ISSN-L)
  • 1532-849X
OpenAlex
W2024830835
Cited by
147
References
1
FWCI
6.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An In Vitro Comparison of Vertical Marginal Gaps of CAD/CAM Titanium and Conventional Cast Restorations. https://app.cochat.ai/papers/10.1111/j.1532-849x.2008.00302.x
The paper
Tan, P. L., Gratton, D. G., Diaz‐Arnold, A. M., & Holmes, D. C. (2008). An In Vitro Comparison of Vertical Marginal Gaps of CAD/CAM Titanium and Conventional Cast Restorations. Journal of Prosthodontics. https://doi.org/10.1111/j.1532-849x.2008.00302.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.