Non-invasive measurement of arterial blood pressure in dogs: a potential indicator for the identification of stress.
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The reproducibility of indirect measurements of arterial pressure in dogs was assessed using the Dinamap 1846 SX oscillometric monitor and tail cuffs. Measurements on different days correlated excellently in 20 working dogs, with indistinguishable group means for systolic, diastolic and mean arterial pressure, whereas heart rates differed, though not significantly. The similarity of the means did not simply result from 'cancelling out' of individual variations; the rank correlation was also highly significant (P < 0.01 diastolic, P < 0.002 systolic). Remeasurement in the veterinary clinic, rather than 'neutral territory' showed significant increases in pressure but not heart rate. Anticipation of work raised systolic pressure whereas heart rate and diastolic pressure were unchanged. Exposure of a dog to a known stressor for that individual (sound) raised systolic and diastolic pressure as well as heart rate; diastolic pressure was the fastest to recover, heart rate the slowest. The data are compared with other observations on non-invasive blood pressure measurement in both dogs and humans.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The white coat hypertension was already documented in dogs (REMILLARD et al., 1991; VINCENT et al., 1993; KALLET et al., 1997; BODEY & MICHELL, 1997; MOESGAARD et al., 2007);”
From Systolic blood pressure of dogs at hospital and domestic environment (2012) · cites this paper as VINCENT et al., 1993
In the citing paper
“The increase of BP in the hospital environment, known as white coat hypertension, is well described in humans and has already been studied in dogs (REMILLARD et al., 1991; VINCENT et al., 1993; KALLET et al., 1997; BODEY & MICHELL, 1997; MOESGAARD et al., 2007) and cats (BELEW et al., 1999).”
From Systolic blood pressure of dogs at hospital and domestic environment (2012) · cites this paper as VINCENT et al., 1993
In the citing paper
“In dogs, a change of sympathetic tone caused by the presence of foreign people and/or environment is mainly responsible for the fast increase of BP under clinical conditions (VINCENT et al., 1993).”
From Systolic blood pressure of dogs at hospital and domestic environment (2012) · cites this paper as VINCENT et al., 1993
In the citing paper
“Also, the canine population is very heterogeneous, and BP values may be influenced by age, sex, breed, size, body condition, exercise regimen of the animals, and by the method of measurement (VINCENT et al., 1993; BODEY & MICHELL, 1996; BODEY & MICHELL, 1997; MICHELL, 2000; MONTOYA et al., 2006; BROWN et al., 2007; CABRAL et al., 2010).”
From Systolic blood pressure of dogs at hospital and domestic environment (2012) · cites this paper as VINCENT et al., 1993
Citations
Cites
Report of the second Task Force on Blood Pressure Control in Children―1987
Horan, M. J. (1987) · PEDIATRICS · Cited by 1,125
"White coat" versus "sustained" borderline hypertension in Tecumseh, Michigan.
Julius, S., Mejia, A., Jones, K., Krause, L., Schork, N., van de Ven, C., Johnson, E., Petrin, J., Sekkarie, M. A., & Kjeldsen, S. E. (1990) · Hypertension · doi:10.1161/01.hyp.16.6.617 · Cited by 272
Biological and Psychological Factors in Cardiovascular Disease
(1986) · Springer eBooks · doi:10.1007/978-3-642-71234-0 · Cited by 228
Comparison of cortisol concentrations in saliva and plasma of dogs.
Vincent, I. C., & Michell, A. R. (1992) · Research in Veterinary Science · doi:10.1016/0034-5288(92)90137-q · Cited by 172
Self-citationComparison of direct and indirect blood pressure measurement in anesthetized dogs.
Sawyer, D. C., Brown, M., Striler, E. L., Durham, R. A., Langham, M., & Rech, R. H. (1991) · PubMed · Cited by 76
Measurement of Systemic Arterial Blood Pressure
Kittleson, M. D., & Olivier, N. B. (1983) · Veterinary Clinics of North America Small Animal Practice · doi:10.1016/s0195-5616(83)50032-6 · Cited by 69
Blood pressures obtained by indirect measurement in conscious dogs
Coulter, D. B., & Keith, J. C. (1984) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.1984.184.11.1375 · Cited by 61
The Effect of Cuff Width on Accuracy of Indirect Measurement of Blood Pressure in Dogs
Valtonen, M., & Eriksson, L. (1970) · Research in Veterinary Science · doi:10.1016/s0034-5288(18)34303-0 · Cited by 56
Physiological Aspects of the Requirement for Sodium in Mammals
Michell, A. R. (1989) · Nutrition Research Reviews · doi:10.1079/nrr19890012 · Cited by 42
Self-citationClinical significance of "white coat" hypertension.
Mancia, G., & Parati, G. (1990) · Hypertension · doi:10.1161/01.hyp.16.6.624 · Cited by 37
Cited by
Brown, S., Atkins, C., Bagley, R., Carr, A., Cowgill, L., Davidson, M., Egner, B., Elliott, J., Henik, R., Labato, M., et al. (2007) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2007.tb03005.x · Cited by 748
Epidemiological study of blood Sressure in omestic dogs
Bodey, A. R., & Michell, A. R. (1996) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.1996.tb02358.x · Cited by 251
Self-citationEvaluation of the Effects of Hospital Visit Stress on Physiologic Parameters in the Cat
Quimby, J. M., Smith, M. L., & Lunn, K. F. (2011) · Journal of Feline Medicine and Surgery · doi:10.1016/j.jfms.2011.07.003 · Cited by 203
Kallet, A. J., Cowgill, L. D., & Kass, P. H. (1997) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.1997.210.05.651 · Cited by 63
Stepien, R. L., Rapoport, G. S., Henik, R. A., Wenholz, L., & Thomas, C. B. (2003) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2003.tb01325.x · Cited by 62
“Mean (SD) Range 160 (27) 95–204 156 (22) 99–191 165 (33) 116–243”
Metadata
- Authors
- Vincent, I. C., Michell, A. R., & Leahy, R. A.
- Affiliations
- University of London (GB)
- Venue
- Research in Veterinary Science
- Publisher
- Elsevier BV
- Published
- 1993-03
- Volume
- 54
- Issue
- 2
- Pages
- 195-201
- ISSN
- 0034-5288 (ISSN-L)
- OpenAlex
- W2032630532
- Cited by
- 42
- References
- 19
- Citations by year
- 2025: 1 · 2024: 1 · 2022: 1 · 2021: 1 · 2018: 2 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 3
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Research in Veterinary Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Life Sciences › Agricultural and Biological Sciences › Animal Science and Zoology › Animal Behavior and Welfare Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- arterial blood pressure, dogs, non-invasive blood pressure measurement, oscillometric blood pressure, stress response, heart rate, working dogs, stress exposure, anticipatory stress
- MeSH terms
- Animals, Arteries, Blood Pressure, Blood Pressure Determination, Dog Diseases, Dogs, Female, Heart Rate, Male, Sound, Stress, Physiological, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive measurement of arterial blood pressure in dogs: a potential indicator for the identification of stress. https://app.cochat.ai/papers/10.1016/0034-5288(93)90056-l
- The paper
- Vincent, I. C., Michell, A. R., & Leahy, R. A. (1993). Non-invasive measurement of arterial blood pressure in dogs: a potential indicator for the identification of stress. Research in Veterinary Science. https://doi.org/10.1016/0034-5288(93)90056-l
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.