Systolic blood pressure of dogs at hospital and domestic environment
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index; 9 of the 33 sources its claims cite were checked for support.
Abstract
The measurement of blood pressure (BP) is an important assessment of the cardiovascular system, being influenced by physical and pathological conditions. Certain situations of stress and anxiety during BP measurement can lead to elevated values in small animals, known in medicine as "white coat effect". The aim of this research was to compare systolic blood pressure (SBP) measurement using Doppler ultrasonography in 45 adult healthy dogs in two environments, at a veterinary hospital and at home. Comparison of heart rate, serum concentrations of cortisol and glucose intended to help the evaluation of the stress level of the animals. The mean of SBP at the veterinary hospital was 154.7mmHg and it was significantly (P<0.01) higher than at home (136.3mmHg). It was also observed that HR (mean=122.7bpm), and serum cortisol (median=4.5µg dL-1) and glucose (mean=95.9mg dL-1) concentrations were significantly higher (P<0.01) at the hospital, when compared with values obtained at home (109.6bpm; 1.5µg dL-1 and 85.5mg dL-1, respectively). In conclusion, the environment can influence SBP in dogs, due to factors related to stress.
Overview
CoChat Summary
TL;DR
In 45 healthy adult dogs, systolic blood pressure measured by Doppler ultrasonography was significantly higher at a veterinary hospital (154.7 mmHg) than at home (136.3 mmHg), alongside higher heart rate, serum cortisol, and glucose. The findings support a white-coat effect in dogs and suggest that a single hospital measurement is insufficient to diagnose hypertension.
Key findings
- Mean SBP was significantly higher at the veterinary hospital (154.7 ± 24.9 mmHg) than at home (136.3 ± 21.2 mmHg; P<0.01).
- Heart rate (122.7 ± 26.2 vs. 109.6 ± 25.2 bpm), serum cortisol (median 4.5 vs. 1.5 µg dL⁻¹), and glucose (95.9 ± 13.3 vs. 85.5 ± 15.5 mg dL⁻¹) were also significantly higher at the hospital than at home (P<0.01).
- At home, 5 dogs (11%) had SBP between 160–179 mmHg and 2 (4%) had SBP above 180 mmHg; at the hospital, 8 dogs (18%) had SBP between 160–179 mmHg and 6 (13%) had SBP above 180 mmHg.
- Two dogs with mean hospital SBP of 218 mmHg had normal physical examination and complementary tests, and their home SBP was below 160 mmHg, supporting a white-coat effect.
Methods
- Fifty-two dogs with normal body condition score were screened; 45 were considered healthy based on clinical history, physical examination, ECG, CBC, liver and renal evaluation, and SBP measurement. Seven were excluded for systemic hypertension (2), leucocytosis (1), increased ALT (1), murmur (1), or arrhythmias (2).
- SBP was measured twice in each dog, once at home and once at the University Veterinary Hospital, with a 5–12 day interval; 22 dogs had the first measurement at home and 23 at the hospital. Doppler ultrasonography was used with standardized acclimation, positioning, cuff width at 40% of limb circumference, and the mean of five measurements after discarding the first.
- SBP, HR, and glucose were compared with paired t-tests; cortisol with Wilcoxon test; and possible order-of-measurement influence with Mann Whitney test. P<0.01 was considered significant.
Limitations
- The paper states that further studies are needed to determine whether white-coat hypertension in dogs is benign or predicts diseases such as renal or cardiovascular alterations, and that the relation of hospital BP increases to systemic disease development is unknown.
- The paper notes that the canine population is heterogeneous and BP may be influenced by age, sex, breed, size, body condition, exercise regimen, and measurement method, so further studies are needed to see if white-coat hypertension differs among these groups.
- Evident from the text: the study included only 45 healthy adult dogs, so findings may not generalize to diseased dogs or other populations; the effects of anxiety on BP are described as unpredictable, and the study did not blind examiners to environment/order, although the same personnel and standardized behavior were used.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
6 Valid · 1 Not valid · 12 Not checked · 25 Own results and interpretations
Some cited sources support this claim and some don’t — read each source’s verdict below.
In the paper
“The white coat hypertension was already documented in dogs (REMILLARD et al., 1991; VINCENT et al., 1993; KALLET et al., 1997; BODEY & MICHELL, 1997; MOESGAARD et al., 2007);”
What the sources say
- Disputedcites REMILLARD et al., 1991 sourceExperimental — accuracy not yet measured
The Discussion explicitly says that the expected rise in blood pressure during a clinic visit due to excitement or fear “was not found in our dogs.” The Results likewise report no significant difference between clinic and home systolic or diastolic blood pressure, although heart rate was higher in the clinic. Our copy provides no page number for these passages. (LLM, conf=0.92)
Checked by a reasoning model — may be wrong.
- Not checked — no full text of the sourcecites VINCENT et al., 1993 source
- Supportedcites KALLET et al., 1997 source
The Discussion (page not supplied) reports that none of the dogs met the study’s hypertension criteria at home, whereas 5 of 14 did during initial clinic measurements. It describes the higher initial clinic pressures as compatible with stress or anxiety, supporting the claim that a white-coat-like effect had been documented in dogs. (LLM, conf=0.92)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“In the present study, the mean values of SBP found at the two environments can be considered similar when compared to other studies performed in healthy dogs, using noninvasive methods (REMILLARD et al., 1991; BODEY & MICHELL, 1996; STEPIEN et al., 2003; CABRAL et al., 2010).”
What the sources say
- Supportedcites REMILLARD et al., 1991 source
The Discussion reports that blood-pressure results from healthy dogs measured at home compared favorably with results from healthy dogs measured indirectly in a clinical setting. It also states that systolic arterial pressure values from the study’s healthy-dog samples under different conditions had greatly overlapping confidence intervals. The supplied passages do not give page numbers. (LLM, conf=0.90)
- Not checked — no full text of the sourcecites BODEY & MICHELL, 1996 source
- Not checked — no full text of the sourcecites STEPIEN et al., 2003 source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“In addition, all SBP measurements were made between 9:00 and 16:00 hours, avoiding the two pressure peaks described in dogs, which correspond to 8:00 and 19:00 hours (MISHINA et al., 1999).”
What the sources say
- Supportedcites MISHINA et al., 1999 source
In “Examination into diurnal BP variations,” the paper reports that hourly averages of systolic, mean, and diastolic blood pressure in dogs showed peaks at 8:00 and 19:00. The 9:00–16:00 measurement schedule describes the citing authors’ own procedure, not a finding attributed to Mishina et al. (LLM, conf=0.94)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“This method is more accurate to measure the systolic than diastolic pressure (BROWN et al., 2007; CABRAL et al., 2010)”
What the sources say
- Not checked — no full text of the sourcecites BROWN et al., 2007 source
- Supportedcites CABRAL et al., 2010 source
The Conclusions report that Doppler provides reliable systolic blood-pressure values in dogs, while diastolic values do not correlate with those from the oscillometric method. The Results also describe Doppler diastolic measurement as subjective. Together, these support the citing sentence’s comparative point. (LLM, conf=0.87)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“There was no influence of location of the first assessment over the SBP values observed at both environments (P=0.72).”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
10 more claims
Create a free account to see all 44 claims and every source verdict.
- It may state two separate claims as one. 20
- Probably not a substantial claim. 14
Citations
Cites
Clinical Biochemistry of Domestic Animals
(1970) · Elsevier eBooks · doi:10.1016/c2013-0-10928-2 · Cited by 3,699
Clinical Biochemistry of Domestic Animals
(1980) · Elsevier eBooks · doi:10.1016/c2013-0-10929-4 · Cited by 1,791
Guyton, A. C., & Hall, J. E. (2011) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 1,096
Brown, S., Atkins, C., Bagley, R., Carr, A., Cowgill, L., Davidson, M., Egner, B., Elliott, J., Henik, R., Labato, M., et al. (2007) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2007.tb03005.x · Cited by 748
Behavioural, saliva cortisol and heart rate responses to different types of stimuli in dogs
Beerda, B., Schilder, M. B. H., van Hooff, J. A. R. A. M., de Vries, H. W., & Mol, J. A. (1998) · Applied Animal Behaviour Science · doi:10.1016/s0168-1591(97)00145-7 · Cited by 574
Brown, S. A., Atkins, C. E., Bagley, R., et al. (2007) · Journal of Veterinary Internal Medicine · doi:10.1892/0891-6640(2007)21[542:gftiea]2.0.co;2 · Cited by 556
Mancia, G., Parati, G., Hennig, M., Flatau, B., Omboni, S., Glavina, F., Costa, B., Scherz, R., Bond, G., & Zanchetti, A. (2001) · Journal of Hypertension · doi:10.1097/00004872-200111000-00008 · Cited by 291 · cited 1×
“This method is more accurate to measure the systolic than diastolic pressure (BROWN et al., 2007; CABRAL et al., 2010), and it was demonstrated that systolic pressure is more important to assess tissue damage related to hypertension (MANCIA et al., 2001; MENTARI & RAHMAN, 2004).”
MethodWhite-Coat Hypertension: New Insights From Recent Studies
Franklin, S. S., Thijs, L., Hansen, T. W., O’Brien, E., & Staessen, J. A. (2013) · Hypertension · doi:10.1161/hypertensionaha.113.01275 · Cited by 274
Samols, E. (1991) · Raven Press eBooks · Cited by 255
Epidemiological study of blood Sressure in omestic dogs
Bodey, A. R., & Michell, A. R. (1996) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.1996.tb02358.x · Cited by 251 · cited 2×
“In the present study, the mean values of SBP found at the two environments can be considered similar when compared to other studies performed in healthy dogs, using noninvasive methods (REMILLARD et al., 1991; BODEY & MICHELL, 1996; STEPIEN et al., 2003; CABRAL et al., 2010).”
MethodResult
Research works printed but not linked: 3
- GELEILETE T.J.M., 2009, Medida ambulatorial da pressão arterial., Revista Brasileira de Hipertensão, 16, 242
- GOOSE P., 2000, Os hormônios adrenocorticais., 813
- TILLEY L.P., 2002, Hipertensão sistêmica., 313
Cited by
Nasciutti, P. R., Moraes, A. T., Santos, T. K., Queiroz, K. K. G., Costa, A. P. A., Amaral, A. R., Olivindo, R. F. G., Pontieri, C. F. F., Jeremias, J. T., Vendramini, T. H. A., et al. (2021) · PLoS ONE · doi:10.1371/journal.pone.0254887 · Cited by 22
“Both arrhythmias are commonly associated with moments of bradycardia [44].”
BackgroundEdwards, P. T., Smith, B. P., McArthur, M. L., & Hazel, S. J. (2022) · Journal of Veterinary Behavior · doi:10.1016/j.jveb.2022.03.003 · Cited by 24
de Sousa, F. G., de Oliveira, B. N. L., Ferreira, N. S., Baldi, M. L. C., Queiroz, F., & Beier, S. L. (2023) · Veterinária e Zootecnia · doi:10.35172/rvz.2023.v30.1542 · Cited by 6
“Para cães e gatos, alguns estudos, embora escassos, apontam que existem diferenças entre as mensurações e dessa forma, seria uma alternativa mais correta para inferir em um diagnóstico real de HAS (26,27).”
Backgroundde Sousa, F. G., Queiroz, F. S. F., Muzzi, R. A. L., Veado, J. C. C., & Beier, S. L. (2025) · Veterinary Sciences · doi:10.3390/vetsci12050453 · Cited by 6
Effectiveness of providing a box, or partially covering the cage front, on reducing cat stress
Wright, C., & Baugh, S. (2018) · The Veterinary Nurse · doi:10.12968/vetn.2018.9.6.328 · Cited by 6
Metadata
- Authors
- Soares, F. A. C., Neuwald, E. B., Mombach, V. S., D'Avila, A. E. R., Conrado, F. D. O., & González, F. H. D.
- Affiliations
- Universidade Federal do Rio Grande do Sul (BR)
- UFRGS, Brasil
- Venue
- Ciência Rural
- Publisher
- FapUNIFESP (SciELO)
- Published
- 2012-06-14
- Volume
- 42
- Issue
- 7
- Pages
- 1242-1248
- ISSN
- 0103-8478 (ISSN-L)
- 1678-4596
- OpenAlex
- W2098270243
- Cited by
- 13
- References
- 33
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 1 · 2018: 2 · 2013: 3
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- Locations
- Ciência Rural (publishedVersion, cc-by-nc)
- Redalyc (Universidad Autónoma del Estado de México) (submittedVersion)
- The Scientific Electronic Library Online (Fundação de Amparo à Pesquisa do Estado de São Paulo) (submittedVersion, other-oa)
- Topics
- Health Sciences › Veterinary › Small Animals › Veterinary Medicine and Surgery
- Life Sciences › Agricultural and Biological Sciences › Animal Science and Zoology › Animal Behavior and Welfare Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Keywords
- systolic blood pressure, dogs, white coat effect, family environment, stress, heart rate, serum cortisol, serum glucose, Doppler ultrasound
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Systolic blood pressure of dogs at hospital and domestic environment. https://app.cochat.ai/papers/10.1590/s0103-84782012005000036
- The paper
- Soares, F. A. C., Neuwald, E. B., Mombach, V. S., D'Avila, A. E. R., Conrado, F. D. O., & González, F. H. D. (2012). Systolic blood pressure of dogs at hospital and domestic environment. Ciência Rural. https://doi.org/10.1590/s0103-84782012005000036
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.