Trypanosoma brucei: miniature anion-exchange centrifugation technique for detection of low parasitaemias: adaptation for field use
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The miniature anion-exchange/centrifugation (AEC) method, originally developed for the detection of submicroscopic trypanosomaemias in laboratory rodents, has been adapted for the diagnosis of trypanosomiasis in man in the field using blood samples obtained by finger-prick. It has been tested in a survey in The Gambia. The method is shown to be highly sensitive and to fulfil the first essential criteria for exploitation in the field, namely, that it can be operated in the open air under tropical conditions, and that an adequate number of subjects can be examined in a normal working day at an acceptable cost. The method also offers two advantages over the other highly sensitive method applicable to small blood samples, the microhaematocrit buffy-coat microscopy (MBCM) method, namely, that it minimized the requirements for highly critical microscopy and provides, in the same operation, samples of diluted plasma which can be used for serological study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isolation of salivarian trypanosomes from man and other mammals using DEAE-cellulose
Lanham, S. M., & Godfrey, D. G. (1970) · Experimental Parasitology · doi:10.1016/0014-4894(70)90120-7 · Cited by 1,334
An improved parasitological technique for the diagnosis of African trypanosomiasis
Murray, M., Murray, P. K., & McIntyre, W. I. M. (1977) · Transactions of the Royal Society of Tropical Medicine and Hygiene · doi:10.1016/0035-9203(77)90110-9 · Cited by 659
Ultramicro Procedures in Clinical Chemistry
Caraway, W. T., & Fanger, H. (1955) · American Journal of Clinical Pathology · doi:10.1093/ajcp/25.3_ts.317 · Cited by 42
Cited by
Brun, R., Blum, J., Chappuis, F., & Burri, C. (2010) · The Lancet · doi:10.1016/s0140-6736(09)60829-1 · Cited by 926
Options for Field Diagnosis of Human African Trypanosomiasis
Chappuis, F., Loutan, L., Simarro, P., Lejon, V., & Büscher, P. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.1.133-146.2005 · Cited by 362
HUMAN TRYPANOSOMIASIS CAUSED BY TRYPANOSOMA EVANSI IN INDIA: THE FIRST CASE REPORT
JOSHI, P. P., SHEGOKAR, V. R., POWAR, R. M., HERDER, S., KATTI, R., SALKAR, H. R., DANI, V. S., BHARGAVA, A., JANNIN, J., & TRUC, P. (2005) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2005.73.491 · Cited by 310
Laboratory-Acquired Parasitic Infections from Accidental Exposures
Herwaldt, B. L. (2001) · Clinical Microbiology Reviews · doi:10.1128/cmr.14.3.659-688.2001 · Cited by 249
Njiru, Z. K., Mikosza, A. S. J., Matovu, E., Enyaru, J. C. K., Ouma, J. O., Kibona, S. N., Thompson, R. C. A., & Ndung’u, J. M. (2008) · International Journal for Parasitology · doi:10.1016/j.ijpara.2007.09.006 · Cited by 207
“…detection of trypanosomes, a number of diagnostic methods have been developed, including the mini-anion exchange centrifugation technique (mAECT; Lumsden et al., 1979), PCR (Welburn et al., 2001; Gibson et al., 2002; Radwanska et al., 2002; Jamonneau et al., 2003) and recently, a dipstick test…”
Method
Metadata
- Authors
- Lumsden, W. H. R., Kimber, C. D., Evans, D. A., & Doig, S. J.
- Venue
- Transactions of the Royal Society of Tropical Medicine and Hygiene
- Publisher
- Oxford University Press (OUP)
- Published
- 1979-01
- Volume
- 73
- Issue
- 3
- Pages
- 312-317
- ISSN
- 0035-9203 (ISSN-L)
- OpenAlex
- W2027311152
- Cited by
- 170
- References
- 3
- FWCI
- 5.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.