Semianalytical Method for Parametric Study of Tuned Mass Dampers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Based on wind‐tunnel measurements of wind‐induced response of tall buildings, a semianalytical method of performing parametric study of tuned mass dampers for tall buildings is proposed. This method was verified through a series of aeroelastic model tests of buildings with and without mass dampers, and a close agreement between semianalytical and experimental results was found. The method can be used to provide an accurate estimate of motion reduction of a building without having to conduct aeroelastic model tests of mass damper‐building systems. Both the analytical and experimental results show that the effectiveness of tuned mass dampers depends to some extent on the type of wind excitation. The conventional parametric study method, which is based on a white‐noise excitation model, usually overestimates the performance of tuned mass dampers. The practical application of the proposed method and the selection of the optimal mass damper parameters are demonstrated. The limitation of the present study and the required further research are pointed out.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Theory of the Dynamic Vibration Absorber
Ormondroyd, J., & Den Hartog, J. P. (1928) · Transactions of the American Society of Mechanical Engineers · doi:10.1115/1.4058553 · Cited by 779
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Vibration suppression of structures using tuned mass damper technology: A state-of-the-art review
Yang, F., Sedaghati, R., & Esmailzadeh, E. (2022) · Journal of Vibration and Control · doi:10.1177/1077546320984305 · Cited by 306
Optimum Design of Absorber for MDOF Structures
Hadi, M. N. S., & Arfiadi, Y. (1998) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1998)124:11(1272 · Cited by 257
Performance of tuned mass dampers under wind loads
Kwok, K. C. S., & Samali, B. (1995) · Engineering Structures · doi:10.1016/0141-0296(95)00035-6 · Cited by 206
Self-citationUeng, J., Lin, C., & Wang, J. (2008) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.336 · Cited by 36
Metadata
- Authors
- Xu, Y. L., & Kwok, K. C. S.
- Venue
- Journal of Structural Engineering
- Published
- 1994-03
- Volume
- 120
- Issue
- 3
- Pages
- 747-764
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(1994)120:3(747
- OpenAlex
- W2075962436
- Cited by
- 29
- References
- 1
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Semianalytical Method for Parametric Study of Tuned Mass Dampers. https://app.cochat.ai/papers/10.1061/(asce)0733-9445(1994)120:3(747
- The paper
- Xu, Y. L., & Kwok, K. C. S. (1994). Semianalytical Method for Parametric Study of Tuned Mass Dampers. Journal of Structural Engineering. https://doi.org/10.1061/(asce)0733-9445(1994)120%3A3(747
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.