Stochastic analysis of myoelectric temporal signatures for multifunctional single-site activation of prostheses and orthoses
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper is concerned with a stochastic time-series analysis of the temporal signatures of myoelectric (ME) signals including the determination of model order and sampling rate. The paper considers the use of time-series parameters for the activation of artificial limbs for high-level amputees, of stimulation electrodes or of powered braces for paralysed persons, in several degrees of freedom, from a single or two surface-electrode pairs at locations where considerable ME cross-talk exists. The multifunctional capability from a single site is based on the differences between the time-series (TS) parameters for different muscle activation patterns at the same ME site, these differences being thus used for limb function discrimination via easily trainable muscle activation patterns at the vicinity of the electrode site. Specifically, the analysis is in terms of identifying the AR parameters of a time-domain autoregressive (AR) signature model both for the complete ME spectrum and for parts thereof, and in terms of the autocorrelation of the signal and of the models residual. Determination of sampling rate and of model orders is discussed in detail. It is shown that, using online real-time analysis, differences in the AR time-series parameters can be observed for different trainable patterns of muscle activation, at the same electrode location, even at the same ME power levels, as long as considerable cross-talk exists at the electrode site. These parameter differences can be accentuated if one considers the AR parameters for lower-frequency spectral windows. A case is made in this paper for employing TS analysis to squeeze out information in a distinct but low-level ripple of the low frequency spectrum of the signal. This information tends to be ignored in frequency domain, but is all that the AR parameters care for in TS analysis, since they are not concerned, with a flat-average low-frequency spectrum, i.e., its white-noise-like part, which is the residual term of the AR Model and not an AR parameter. Discrimination between different functions from a single electrode-site, at even the same power level, is thus shown to require considerable cross-talk at the given site, and to require the consideration of only the low-frequency part of the spectrum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Self-citation
Cited by
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Evaluation of the forearm EMG signal features for the control of a prosthetic hand
Boostani, R., & Moradi, M. H. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/307 · Cited by 391
Metadata
- Authors
- Graupe, D., Salahi, J., & Zhang, D.
- Venue
- Journal of Biomedical Engineering
- Publisher
- IOP Publishing
- Published
- 1985-01-01
- Volume
- 7
- Issue
- 1
- Pages
- 18-29
- ISSN
- 0141-5425 (ISSN-L)
- OpenAlex
- W2054538394
- Cited by
- 97
- References
- 1
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stochastic analysis of myoelectric temporal signatures for multifunctional single-site activation of prostheses and orthoses. https://app.cochat.ai/papers/10.1016/0141-5425(85)90004-4
- The paper
- Graupe, D., Salahi, J., & Zhang, D. (1985). Stochastic analysis of myoelectric temporal signatures for multifunctional single-site activation of prostheses and orthoses. Journal of Biomedical Engineering. https://doi.org/10.1016/0141-5425(85)90004-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.