Polymer membranes in clinical sensor applications
The DOI matches its Crossref record; 126 of the 133 references it cites were found in a registry or an index.
Abstract
Polymer membranes are used in a wide variety of molecular sensing devices many of which are of potential clinical interest. The role of the polymer and the physical properties required of it are, however, rarely clearly defined. An extensive review is presented of the range of polymers whose use as membranes is described in the sensor literature. This forms the basis of an overview of membrane function in potentiometric amperometric and fibre optic sensors. In particular, the interaction of permeability, permselectivity and transmembrane potential is highlighted, together with the role of polymer membranes as matrices for the immobilization of reactive chemical and biological agents.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The biggest drawback to this technique is the large dispersity and poor control over molecular mass.”
From Quaternary ammonium-based biomedical materials: State-of-the-art, toxicological aspects and antimicrobial resistance (2017) · cites this paper as [120]
Citations
Cites
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
PVC matrix membrane ion-selective electrodes. Construction and laboratory experiments
Craggs, A., Moody, G. J., & Thomas, J. D. R. (1974) · Journal of Chemical Education · doi:10.1021/ed051p541 · Cited by 533
Hwang, S., & Kammermeyer, K. (1975) · Cited by 482
Chemical Sensors Based on Fiber Optics
Seitz, W. R. (1984) · Analytical Chemistry · doi:10.1021/ac00265a001 · Cited by 417
Ion-Selective Electrodes in Analytical Chemistry
(1978) · Springer eBooks · doi:10.1007/978-1-4684-2592-5 · Cited by 383
Jhon, M. S., & Andrade, J. D. (1973) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820070604 · Cited by 324
Fiber-Optic Sensors for Biomedical Applications
Peterson, J. I., & Vurek, G. G. (1984) · Science · doi:10.1126/science.6422554 · Cited by 300
Potassium ion-sensitive field effect transistor
Moss, S. D., Janata, J., & Johnson, C. C. (1975) · Analytical Chemistry · doi:10.1021/ac60363a005 · Cited by 237
Theory and applications of ion-selective electrodes
Koryta, J. (1972) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)95071-8 · Cited by 213
Cited by
Jiao, Y., Niu, L.-N., Ma, S., Li, J., Tay, F. R., & Chen, J.-H. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.03.001 · Cited by 639
Biosensors for chemical and biological agents of defence interest
Paddle, B. M. (1996) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)82333-5 · Cited by 240
Imprinted Polymer Membranes for the Selective Transport of Targeted Neutral Molecules
Mathew, J., & Shea, K. J. (1996) · Journal of the American Chemical Society · doi:10.1021/ja954066j · Cited by 202
Thin Hydrogel Films for Optical Biosensor Applications
Mateescu, A., Wang, Y., Dostalek, J., & Jonas, U. (2012) · Membranes · doi:10.3390/membranes2010040 · Cited by 189
A novel self-assembled monolayer (SAM) coated microcantilever for low level caesium detection
Ji, H., Dabestani, R., Brown, G. M., & Britt, P. F. (2000) · Chemical Communications · doi:10.1039/a908143g · Cited by 134
Metadata
- Authors
- Davies, M. L., Hamilton, C. J., Murphy, S. M., & Tighe, B. J.
- Affiliations
- Aston University (GB)
- Corresponding author
- Tighe, B.J.
- ORCID
- Tighe, B.J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1992
- Volume
- 13
- Issue
- 14
- Pages
- 971-978
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1535048972
- Cited by
- 47
- References
- 133
- Citations by year
- 2025: 2 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 1 · 2018: 1 · 2017: 3 · 2016: 2 · 2015: 1 · 2014: 4 · 2013: 1 · 2012: 1
- FWCI
- 0.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- polymer membranes, molecular detection, potentiometric sensors, amperometric sensor, fiber optic sensors, membrane permeability, permselectivity, membrane potential, chemical sensors
- MeSH terms
- Biocompatible Materials, Electrochemistry, Enzymes, Immobilized, Fiber Optic Technology, Humans, Membrane Potentials, Membranes, Artificial, Permeability, Polymers, Potentiometry, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polymer membranes in clinical sensor applications. https://app.cochat.ai/papers/10.1016/0142-9612(92)90147-g
- The paper
- Davies, M. L., Hamilton, C. J., Murphy, S. M., & Tighe, B. J. (1992). Polymer membranes in clinical sensor applications. Biomaterials. https://doi.org/10.1016/0142-9612(92)90147-g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.