Polymer membranes in clinical sensor applications
The DOI matches its Crossref record; 126 of the 133 references it cites were found in a registry or an index.
Abstract
Polymer membranes are used in a wide variety of molecular sensing devices many of which are of potential clinical interest. The role of the polymer and the physical properties required of it are, however, rarely clearly defined. An extensive review is presented of the range of polymers whose use as membranes is described in the sensor literature. This forms the basis of an overview of membrane function in potentiometric amperometric and fibre optic sensors. In particular, the interaction of permeability, permselectivity and transmembrane potential is highlighted, together with the role of polymer membranes as matrices for the immobilization of reactive chemical and biological agents.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The biggest drawback to this technique is the large dispersity and poor control over molecular mass.”
From Quaternary ammonium-based biomedical materials: State-of-the-art, toxicological aspects and antimicrobial resistance (2017) · cites this paper as [120]
Citations
Cites
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
PVC matrix membrane ion-selective electrodes. Construction and laboratory experiments
Craggs, A., Moody, G. J., & Thomas, J. D. R. (1974) · Journal of Chemical Education · doi:10.1021/ed051p541 · Cited by 533
Hwang, S., & Kammermeyer, K. (1975) · Cited by 482
Chemical Sensors Based on Fiber Optics
Seitz, W. R. (1984) · Analytical Chemistry · doi:10.1021/ac00265a001 · Cited by 417
Ion-Selective Electrodes in Analytical Chemistry
(1978) · Springer eBooks · doi:10.1007/978-1-4684-2592-5 · Cited by 383
Jhon, M. S., & Andrade, J. D. (1973) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820070604 · Cited by 324
Fiber-Optic Sensors for Biomedical Applications
Peterson, J. I., & Vurek, G. G. (1984) · Science · doi:10.1126/science.6422554 · Cited by 300
Potassium ion-sensitive field effect transistor
Moss, S. D., Janata, J., & Johnson, C. C. (1975) · Analytical Chemistry · doi:10.1021/ac60363a005 · Cited by 237
Theory and applications of ion-selective electrodes
Koryta, J. (1972) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)95071-8 · Cited by 213
Electron Resists for Microcircuit and Mask Production
Hatzakis, M. (1969) · Journal of The Electrochemical Society · doi:10.1149/1.2412145 · Cited by 203
Munkholm, C., Walt, D. R., Milanovich, F. P., & Klainer, S. M. (1986) · Analytical Chemistry · doi:10.1021/ac00298a034 · Cited by 201
Hydrogels in Biomedical Applications
Pedley, D. G., Skelly, P. J., & Tighe, B. J. (1980) · British Polymer Journal · doi:10.1002/pi.4980120306 · Cited by 198
Self-citationNeutral carrier based ion-selective electrode for the determination of total calcium in blood serum
Anker, P., Wieland, E., Ammann, D., Dohner, R. E., Asper, R., & Simon, W. (1981) · Analytical Chemistry · doi:10.1021/ac00236a005 · Cited by 185
Fiber-optic evanescent field absorption sensor
Paul, P. H., & Kychakoff, G. (1987) · Applied Physics Letters · doi:10.1063/1.98888 · Cited by 183
Janata, J., & Bezegh, A. (1988) · Analytical Chemistry · doi:10.1021/ac00163a004 · Cited by 183
Lee, H. B., Jhon, M. S., & Andrade, J. D. (1975) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(75)90107-1 · Cited by 181
Remote fiber-optic biosensors based on evanescent-excited fluoro-immunoassay: Concept and progress
Andrade, J. D., VanWagenen, R. A., GREGONIS, D. E., Newby, K., & Lin, J. N. (1985) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1985.22096 · Cited by 175
Reversible optical waveguide sensor for ammonia vapors
Giuliani, J. F., Wohltjen, H., & Jarvis, N. L. (1983) · Optics Letters · doi:10.1364/ol.8.000054 · Cited by 172
Synthetic hydrogels: 1. Hydroxyalkyl acrylate and methacrylate copolymers - water binding studies
Corkhill, P. H., Jolly, A. M., Ng, C. O., & Tighe, B. J. (1987) · Polymer · doi:10.1016/0032-3861(87)90021-8 · Cited by 168
Self-citationUrease coupled ammonia electrode for urea determination in blood serum
Mascini, M., & Guilbault, G. G. (1977) · Analytical Chemistry · doi:10.1021/ac50014a031 · Cited by 165
A hydrogen ion-selective liquid-membrane electrode based on tri-n-dodecylamine as neutral carrier
Schulthess, P., Shijo, Y., Pham, H. V., Pretsch, E., Ammann, D., & Simon, W. (1981) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)93540-8 · Cited by 163
Oxygen plasma removal of thin polymer films
Taylor, G. N., & Wolf, T. M. (1980) · Polymer Engineering & Science · doi:10.1002/pen.760201610 · Cited by 161
Optical pH sensor based on the chemical modification of a porous polymer film
Jones, T. P., & Porter, M. D. (1988) · Analytical Chemistry · doi:10.1021/ac00156a006 · Cited by 161
Beam displacement at total reflection : The Goos-Hanchen effect I
Lotsch, H. K. V. (1970) · Optik · Cited by 152
Andrade, J. D., King, R. N., Gregonis, D. E., & Coleman, D. L. (1979) · Journal of Polymer Science: Polymer Symposia · doi:10.1002/polc.5070660130 · Cited by 149
Permselectivity of solutes in homogeneous water-swollen polymer membranes
Yasuda, H. K., & Lamaze, C. E. (1971) · Journal of Macromolecular Science Part B · doi:10.1080/00222347108212523 · Cited by 146
Antibody-Based Fiberoptics Biosensor for the Carcinogen Benzo(a)pyrene
Vo‐Dinh, T., Tromberg, B. J., Griffin, G. D., Ambrose, K. R., Sepaniak, M. J., & Gardenhire, E. M. (1987) · Applied Spectroscopy · doi:10.1366/0003702874448076 · Cited by 142
A fiber-optic sensor for CO2 measurement
Munkholm, C., Walt, D. R., & Milanovich, F. P. (1988) · Talanta · doi:10.1016/0039-9140(88)80047-x · Cited by 140
Ascorbate electrode for determination of L-ascorbic acid in food
Matsumoto, K., YAMADA, K., & Osajima, Y. (1981) · Analytical Chemistry · doi:10.1021/ac00236a006 · Cited by 134
Mascini, M., Iannello, M., & Palleschi, G. (1983) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)80600-5 · Cited by 126
Fatt, I. (1976) · Cited by 125
Synthetic hydrogels as drug delivery systems
Roorda, W. E., Boddé, H. E., de Boer, A. G., & Junginger, H. E. (1986) · Pharmacy World & Science · doi:10.1007/bf01959775 · Cited by 121
pH-based enzyme potentiometric sensors. Part 2. Glucose-sensitive field effect transistor
Caras, S. D., Petelenz, D., & Janata, J. (1985) · Analytical Chemistry · doi:10.1021/ac00286a028 · Cited by 119
Ion-Sensitive Field Effect Transistors
Janata, J., & Huber, R. J. (1980) · Selective electrode reviews · doi:10.1016/b978-0-08-026044-0.50006-8 · Cited by 119
Sibbald, A., Whalley, P. D., & Covington, A. K. (1984) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)84280-4 · Cited by 118
Bioselective Membrane Electrode Probes
RECHNITZ, G. A. (1981) · Science · doi:10.1126/science.7280694 · Cited by 116
Permeation of water through some hydrogels
Refojo, M. F. (1965) · Journal of Applied Polymer Science · doi:10.1002/app.1965.070091019 · Cited by 116
Chemically Sensitive Field Effect Transistors
Janata, J., & Huber, R. J. (1980) · Springer eBooks · doi:10.1007/978-1-4684-3776-8_3 · Cited by 115
Lübbers, D. W., & Opitz, N. (1983) · Sensors and Actuators · doi:10.1016/0250-6874(83)85078-1 · Cited by 113
Oxygen probe based on tetrakis(alkylamino)ethylene chemiluminescence
Freeman, T. M., & Seitz, W. R. (1981) · Analytical Chemistry · doi:10.1021/ac00224a025 · Cited by 105
The Packaging of Implantable Integrated Sensors
Bowman, L., & Meindl, J. D. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325807 · Cited by 103
Water binding properties of hydrogel polymers for reverse osmosis and related applications
Pedley, D. G., & Tighe, B. J. (1979) · British Polymer Journal · doi:10.1002/pi.4980110306 · Cited by 101
Self-citationPlant tissue-based bioselective membrane electrode for glutamate
Kuriyama, S., & RECHNITZ, G. A. (1981) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)93537-8 · Cited by 99
Wisniewski, S. J., & Kim, S. W. (1980) · Journal of Membrane Science · doi:10.1016/s0376-7388(00)82171-7 · Cited by 98
Potassium ion responsive coated wire electrode based on valinomycin
Cattrall, R. W., Tribuzio, S., & Freiser, H. (1974) · Analytical Chemistry · doi:10.1021/ac60350a026 · Cited by 98
Enzyme-Based Fiber Optic Sensor
Arnold, M. A. (1985) · Analytical Chemistry · doi:10.1021/ac50001a055 · Cited by 92
Freezing and nonfreezing water in cellulose acetate membranes
Frommer, M. A., & Lancet, D. (1972) · Journal of Applied Polymer Science · doi:10.1002/app.1972.070160519 · Cited by 87
Solsky, R. L. (1988) · Analytical Chemistry · doi:10.1021/ac00163a008 · Cited by 84
Ion-selective electrodes based on an ionic polymer
Martin, C. R., & Freiser, H. (1981) · Analytical Chemistry · doi:10.1021/ac00229a037 · Cited by 83
Single fiber-optic fluorescence enzyme-based sensor
Fuh, M. R. S., Burgess, L. W., & Christian, G. D. (1988) · Analytical Chemistry · doi:10.1021/ac00156a012 · Cited by 82
Barnes, A., Corkhill, P. H., & Tighe, B. J. (1988) · Polymer · doi:10.1016/0032-3861(88)90111-5 · Cited by 81
Self-citationSolvent polymeric membrane ion-selective electrodes
Thomas, J. D. R. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80011-3 · Cited by 75
Acetylcholine Sensor Based on Ion Sensitive Field Effect Transistor and Acetylcholine Receptor
Gotoh, M., Tamiya, E., Momoi, M. Y., Kagawa, Y., & Karube, I. (1987) · Analytical Letters · doi:10.1080/00032718708062935 · Cited by 73
pH-based enzyme potentiometric sensors. Part 3. Penicillin-sensitive field effect transistor
Caras, S. D., & Janata, J. (1985) · Analytical Chemistry · doi:10.1021/ac00286a029 · Cited by 73
Optical sensor for sodium based on ion-pair extraction and fluorescence
Zhujun, Z., Mullin, J. L., & Seitz, W. R. (1986) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)86489-2 · Cited by 71
Ion-selective field effect transistors with polymeric membranes
Mcbride, P. T., Janata, J., Comte, P. A., Moss, S. D., & Johnson, C. C. (1978) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)93360-4 · Cited by 67
Plasma‐Developed X‐Ray Resists
Taylor, G. N., & Wolf, T. (1980) · Journal of The Electrochemical Society · doi:10.1149/1.2129569 · Cited by 65
Simplex optimization of a fiber-optic ammonia sensor based on multiple indicators
Rhines, T. D., & Arnold, M. A. (1988) · Analytical Chemistry · doi:10.1021/ac00152a019 · Cited by 63
A new ion sensor based on fiber optics
Bright, F. V., Poirier, G. E., & Hieftje, G. M. (1988) · Talanta · doi:10.1016/0039-9140(88)80048-1 · Cited by 59
Sibbald, A., Covington, A. K., & Carter, R. F. (1984) · Clinical Chemistry · doi:10.1093/clinchem/30.1.135 · Cited by 59
Wyatt, W. A., Bright, F. V., & Hieftje, G. M. (1987) · Analytical Chemistry · doi:10.1021/ac00145a014 · Cited by 56
Refojo, M. F., & Leong, F. (1978) · Journal of Membrane Science · doi:10.1016/s0376-7388(00)83317-7 · Cited by 55
Encapsulation of polymeric membrane-based ion-selective field effect transistors
Ho, N.-T., Kratochvil, J., Blackburn, G. F., & Janata, J. (1983) · Sensors and Actuators · doi:10.1016/0250-6874(83)85052-5 · Cited by 55
Coated Wire Ion-Selective Electrodes
Freiser, H. (1980) · Springer eBooks · doi:10.1007/978-1-4684-3776-8_2 · Cited by 55
Clinical uses of enzyme electrode probes
Mascini, M., & Guilbault, G. G. (1986) · Biosensors · doi:10.1016/0265-928x(86)80002-5 · Cited by 55
Determination of pH with acid—base indicators: Implications for optical fibre probes
Edmonds, T. E., Flatters, N. J., Jones, C. F., & Miller, J. S. (1988) · Talanta · doi:10.1016/0039-9140(88)80046-8 · Cited by 50
Design of anion-selective membranes for clinically relevant sensors
Oesch, U., Ammann, D., Pham, H. V., Wuthier, U., Zünd, R. E., & Simon, W. (1986) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19868201179 · Cited by 50
Neutral lipid enzyme electrode based on ion-sensitive field effect transistors
Nakako, M., Hanazato, Y., Maeda, M., & Shiono, S. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80044-7 · Cited by 50
HAMILTON, C., MURPHY, S., Atherton, N. D., & Tighe, B. J. (1988) · Polymer · doi:10.1016/0032-3861(88)90406-5 · Cited by 49
Self-citationOptical and fibre-optic sensors for vapours of polar solvents
Posch, H. E., Wolfbeis, O. S., & Pusterhofer, J. (1988) · Talanta · doi:10.1016/0039-9140(88)80044-4 · Cited by 45
Synthetic hydrogels: 5. Transport processes in 2-hydroxyethyl methacrylate copolymers
MURPHY, S., HAMILTON, C., & Tighe, B. J. (1988) · Polymer · doi:10.1016/0032-3861(88)90407-7 · Cited by 45
Self-citationPeroxidase-based colorimetric determination of L-ascorbic acid
Thompson, R. Q. (1987) · Analytical Chemistry · doi:10.1021/ac00135a011 · Cited by 44
Remote Detection of Organochlorides With a Fiber Optic Based Sensor
Milanovich, F. P., Garvis, D. G., Angel, S. M., Klainer, S. M., & Eccles, L. A. (1986) · Instrumentation Science & Technology · doi:10.1080/10739148608543604 · Cited by 43
Methods of measuring oxygen tensions of blood and organ surfaces.
Lübbers, D. W. (1966) · PubMed · Cited by 42
Microelectronic approaches to solid state ion selective electrodes*
Kelly, R. G. (1977) · Electrochimica Acta · doi:10.1016/0013-4686(77)85044-5 · Cited by 41
A solid-phase optoelectronic sensor for serum albumin
Goldfinch, M. J., & Lowe, C. R. (1980) · Analytical Biochemistry · doi:10.1016/0003-2697(80)90639-9 · Cited by 41
Valinomycin-doped photoresist layers for potassium ion sensing
Wen, C. C., Lauks, I. R., & ZEMEL, J. N. (1980) · Thin Solid Films · doi:10.1016/0040-6090(80)90374-0 · Cited by 41
Plant tissue-based membrane biosensor for l-ascorbic acid
Macholán, L., & Chmelíková, B. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80045-9 · Cited by 40
Chabay, I. (1982) · Analytical Chemistry · doi:10.1021/ac00246a004 · Cited by 40
Coated-wire ion selective electrodes and their application to the teaching laboratory
Martin, C. R., & Freiser, H. (1980) · Journal of Chemical Education · doi:10.1021/ed057p512 · Cited by 39
Physical characterization of microporous poly(2‐hydroxyethyl methacrylate) gels
Migliaresi, C., Nicodemo, L., Nicolais, L., & Passerini, P. (1981) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820150303 · Cited by 38
Coated-wire ion-selective electrodes
Cunningham, L., & Freiser, H. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80009-5 · Cited by 37
Hanazato, Y., Inatomi, K.-I., Nakako, M., Shiono, S., & Maeda, M. (1988) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)84128-8 · Cited by 35
Coated optical guides for spectrophotometry of chemical reactions
HARDY, E. E., David, D. J., Kapany, N. S., & Unterleitner, F. C. (1975) · Nature · doi:10.1038/257666a0 · Cited by 35
Acetycholine and choline ion-selective microelectrodes
Jaramillo, A., Lopez, S., Justice, J. B., Salamone, J. D., & .Neil, D. B. (1983) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)80601-7 · Cited by 35
Arie, A., Karoubi, R., Gur, Y. S., & Tur, M. (1986) · Applied Optics · doi:10.1364/ao.25.001754 · Cited by 35
A study of insulator materials used in ISFET gates
Cohen, R. M., Huber, R. J., Janata, J., Ure, R. W., & Moss, S. D. (1978) · Thin Solid Films · doi:10.1016/0040-6090(78)90031-7 · Cited by 34
Simple fibre optic pH sensor for use in liquid titrations
Benaim, N., Grattan, K. T. V., & Palmer, A. W. (1986) · The Analyst · doi:10.1039/an9861101095 · Cited by 33
Extrinsic fibre-optic sensors for remote measurement: Part two
Jackson, D. A., & Jones, J. D. C. (1986) · Optics & Laser Technology · doi:10.1016/0030-3992(86)90055-1 · Cited by 32
Ng, C. O., & Tighe, B. J. (1976) · British Polymer Journal · doi:10.1002/pi.4980080403 · Cited by 32
Self-citationPolymer membranes in clinical sensor applications
Murphy, S. M., Hamilton, C., Davies, M. L., & Tighe, B. J. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90148-h · Cited by 31
Self-citationSubmicrogram determination of lanthanides through quenching of calcein blue fluorescence
Brittain, H. G. (1987) · Analytical Chemistry · doi:10.1021/ac00135a012 · Cited by 31
Woods, B. A., Růžička, J., Christian, G. D., & Charlson, R. J. (1986) · Analytical Chemistry · doi:10.1021/ac00125a031 · Cited by 30
Problems in the application of ion-selective electrodes to serum lithium analysis
Gadzekpo, V. P. Y., Moody, G. J., & Thomas, J. D. R. (1986) · The Analyst · doi:10.1039/an9861100567 · Cited by 30
Electron‐beam lithography of chlorinated polystyrenes with narrow molecular weight distributions
Feit, E. D., & Stillwagon, L. E. (1980) · Polymer Engineering and Science · doi:10.1002/pen.760201604 · Cited by 30
Wolfbeis, O. S., Schaffar, B. P. H., & Kaschnitz, E. (1986) · The Analyst · doi:10.1039/an9861101331 · Cited by 28
Theory and applications of ion-selective electrodes
Koryta, J. (1988) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)80828-4 · Cited by 28
Polymer degradation in reactive-gas plasmas
Moss, S. J. (1987) · Polymer Degradation and Stability · doi:10.1016/0141-3910(87)90064-4 · Cited by 27
Ng, C. O., & Tighe, B. J. (1976) · British Polymer Journal · doi:10.1002/pi.4980080303 · Cited by 27
Self-citationBaker, D. A., Corkhill, P. H., Ng, C. O., Skelly, P. J., & Tighe, B. J. (1988) · Polymer · doi:10.1016/0032-3861(88)90086-9 · Cited by 26
Self-citationOptical fibre chemical sensors
Alder, J. F. (1986) · Fresenius Zeitschrift für Analytische Chemie · doi:10.1007/bf00474109 · Cited by 25
Sibbald, A., Covington, A. K., Cooper, E. A., & Carter, R. F. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.2.405 · Cited by 25
Multi-element optical waveguide sensor: General concept and design
Smardzewski, R. R. (1988) · Talanta · doi:10.1016/0039-9140(88)80045-6 · Cited by 25
Enzyme electrode system for assay of serum cholinesterase
Crochet, K. L., & Montalvo, J. G. (1973) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)82538-1 · Cited by 25
A Negative‐Working Plasma‐Developed Photoresist
Taylor, G. N., Wolf, T., & Goldrick, M. R. (1981) · Journal of The Electrochemical Society · doi:10.1149/1.2127422 · Cited by 24
Optical-fibre sensing of fluoride ions in a flow-stream
Narayanaswamy, R., Russell, D. A., & Sevilla, F. (1988) · Talanta · doi:10.1016/0039-9140(88)80043-2 · Cited by 22
Fiber Optic Microfluorimetry for Acute and Chronic In-Vivo Animal Studies
Goldstein, S. R., Bonner, R. F., Dedrick, R. L., Grantham, F. H., Gullino, P. M., Gibson, C. C., & McGuire, D. A. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3149584 · Cited by 21
Biosensors: a revolution in clinical analysis?
Owen, V. M. J., & Turner, A. P. F. (1987) · Endeavour · doi:10.1016/0160-9327(87)90245-6 · Cited by 20
Coated-wire lithium ion-selective electrodes based on polyalkoxylate complexes
Gadzekpo, V. P. Y., Moody, G. J., & Thomas, J. D. R. (1985) · The Analyst · doi:10.1039/an9851001381 · Cited by 19
Milanovich, F. P., Daley, P. F., Klainer, S. M., & Eccles, L. A. (1986) · Instrumentation Science & Technology · doi:10.1080/10739148608543621 · Cited by 19
Electrochemical sensors based on biological principles
Koryta, J. (1986) · Electrochimica Acta · doi:10.1016/0013-4686(86)85026-5 · Cited by 17
Simplified procedure for forming polymer-based ion-selective electrodes
Fogt, E. J., Cahalan, P. T., Jevne, A. H., & Schwinghammer, M. A. (1985) · Analytical Chemistry · doi:10.1021/ac00283a044 · Cited by 16
ENZYME - BASED (FIBRE) OPTIC SENSORS
Wolfbeis, O. S. (1992) · Elsevier eBooks · doi:10.1016/b978-1-85617-161-8.50003-3 · Cited by 15
Selective Transport Membranes and their Applicability for Novel Sensors
Morf, W. E., Huser, M., Lindemann, B., Schulthess, P., & Simon, W. (1986) · Helvetica Chimica Acta · doi:10.1002/hlca.19860690607 · Cited by 15
Uragami, T.-I., Furukawa, T., & Sugihara, M. (1984) · Polymer communications · Cited by 13
Biosensors based on reversible reactions at blocked and unblocked electrodes
Buck, R. P. (1986) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19868201169 · Cited by 11
A Compilation of Ion-Selective Membrane Electrode Literature
Buck, R. P., Thompsen, J. C., & Melroy, O. R. (1980) · Springer eBooks · doi:10.1007/978-1-4684-3776-8_4 · Cited by 10
Ion-selectivity of plasticizers in poly(vinyl chloride) membrane electrodes
Buøen, S., Dale, J., & Lund, W. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80064-2 · Cited by 9
Schubert, F., Scheller, F. W., & Kirstein, D. (1982) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)95306-1 · Cited by 8
An enzyme electrode for acetaldehyde determination
Tipton, K. F., McCrodden, J. M., & Bardsley, M. E. (1981) · Biochemical Society Transactions · doi:10.1042/bst0090324 · Cited by 6
Synthetic hydrogels in contact lens applications
Ng, C. O. (1974) · Aston Publications Explorer (Aston University) · doi:10.48780/publications.aston.ac.uk.00011583 · Cited by 3
Calcium Ion-Selective Electrodes with Covalently-Bound Organo-Phosphate Sensor Groups
Corfield, G. C., Ebdon, L., & Ellis, A. T. (1983) · Springer eBooks · doi:10.1007/978-1-4613-3748-5_24 · Cited by 3
Characterization of Na ion‐sensitive solvent polymeric membranes based on a neutral carrier
Maruizumi, T., Miyagi, H., TAKATA, Y., & Kobayashi, T. (1985) · Journal of Applied Polymer Science · doi:10.1002/app.1985.070300204 · Cited by 3
Resists used in plasma processing
Roberts, E. D. (1985) · Vacuum · doi:10.1016/0042-207x(85)90369-0 · Cited by 2
4415666 Enzyme electrode membrane
D'Orazio, P. (1983) · Biotechnology Advances · doi:10.1016/0734-9750(83)90694-8 · Cited by 1
Cited by
Jiao, Y., Niu, L.-N., Ma, S., Li, J., Tay, F. R., & Chen, J.-H. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.03.001 · Cited by 639
Biosensors for chemical and biological agents of defence interest
Paddle, B. M. (1996) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)82333-5 · Cited by 240
Imprinted Polymer Membranes for the Selective Transport of Targeted Neutral Molecules
Mathew, J., & Shea, K. J. (1996) · Journal of the American Chemical Society · doi:10.1021/ja954066j · Cited by 202
Thin Hydrogel Films for Optical Biosensor Applications
Mateescu, A., Wang, Y., Dostalek, J., & Jonas, U. (2012) · Membranes · doi:10.3390/membranes2010040 · Cited by 189
A novel self-assembled monolayer (SAM) coated microcantilever for low level caesium detection
Ji, H., Dabestani, R., Brown, G. M., & Britt, P. F. (2000) · Chemical Communications · doi:10.1039/a908143g · Cited by 134
Metadata
- Authors
- Davies, M. L., Hamilton, C. J., Murphy, S. M., & Tighe, B. J.
- Affiliations
- Aston University (GB)
- Corresponding author
- Tighe, B.J.
- ORCID
- Tighe, B.J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1992
- Volume
- 13
- Issue
- 14
- Pages
- 971-978
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1535048972
- Semantic Scholar
- f9a28da70335492f3bef780771cc43f6af7de093
- Cited by
- 47
- References
- 133
- Citations by year
- 2025: 2 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 1 · 2018: 1 · 2017: 3 · 2016: 2 · 2015: 1 · 2014: 4 · 2013: 1 · 2012: 1
- FWCI
- 0.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- polymer membranes, molecular detection, potentiometric sensors, amperometric sensor, fiber optic sensors, membrane permeability, permselectivity, membrane potential, chemical sensors
- MeSH terms
- Biocompatible Materials, Electrochemistry, Enzymes, Immobilized, Fiber Optic Technology, Humans, Membrane Potentials, Membranes, Artificial, Permeability, Polymers, Potentiometry, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.