The Packaging of Implantable Integrated Sensors
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Integrated sensors are being designed for long-term implantation for physiological research using animal models and for permanent implantation for various types of prostheses in clinical applications. The problem of packaging these implantable integrated sensors outside of hermetically sealed hybrid packages is described. The electrolytic corrosion of cable conductors and integrated circuit metallizations is the principal danger. The published performance of the materials which have been used to date to encapsulate nonintegrated sensors and conductors is evaluated, and found to be unreliable for these applications. So, too, are the metals which have been used as electrical conductors. New techniques being developed in the attempt to achieve "hermeticity on a chip" are described. Finally, a critical, residual aspect of the overall problem is identified: how to make a mechanically rugged and inherently noncorrodible connection between a cable and a thin film on a silicon chip. No solution to this problem has been demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experimental visual prosthesis
Donaldson, P. E. K. (1973) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1973.0061 · Cited by 58
Cited by
Fang, H., Yu, K. J., Gloschat, C., Yang, Z., Song, E., Chiang, C.-H., Zhao, J., Won, S. M., Xu, S., Trumpis, M., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0038 · Cited by 278
Corrosion of silicon integrated circuits and lifetime predictions in implantable electronic devices
Vanhoestenberghe, A., & Donaldson, N. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/031002 · Cited by 140
Conductively coupled flexible silicon electronic systems for chronic neural electrophysiology
Li, J., Song, E., Chiang, C.-H., Yu, K. J., Koo, J., Du, H., Zhong, Y., Hill, M., Wang, C., Zhang, J., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813187115 · Cited by 65
Polymer membranes in clinical sensor applications
Davies, M. L., Hamilton, C. J., Murphy, S. M., & Tighe, B. J. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90147-g · Cited by 47
Metadata
- Authors
- Bowman, L., & Meindl, J. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1986-02
- Volume
- BME-33
- Issue
- 2
- Pages
- 248-255
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2059588525
- Cited by
- 103
- References
- 1
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Packaging of Implantable Integrated Sensors. https://app.cochat.ai/papers/10.1109/tbme.1986.325807
- The paper
- Bowman, L., & Meindl, J. D. (1986). The Packaging of Implantable Integrated Sensors. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1986.325807
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.