Abstract
A graft copolymer having poly(L-lysine) (PLL) as the backbone and monomethoxy poly(ethylene glycol) (MPEG) as pendent chains was synthesized. This polycationic copolymer was used to form microcapsules with sodium alginate, a polyanion. Microcapsules and model surfaces formed with PLL-graft-MPEG demonstrated reduced protein adsorption, complement binding and cell adhesion in vitro compared to materials with unmodified PLL. Microcapsules with PLL-g-MPEG on the surface were seen to be much more biocompatible than the widely used alginate/PLL/alginate microcapsule in a mouse intraperitoneal implant model. The graft copolymers demonstrated a lower affinity for alginate and increased microcapsule permeability more than PLL. To correct this, pentalayered alginate/PLL/alginate/PLL-g-MPEG/alginate microcapsules were fabricated, and these demonstrated both appropriate permselectivity and enhanced biocompatibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Protein release from alginate matrices
Gombotz, W. R., & Wee, S. F. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.007 · Cited by 1,609
Protein release from alginate matrices
Gombotz, W. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00124-5 · Cited by 1,550
Review: Hydrogels for cell immobilization
Jen, A. C., Wake, M. C., & Mikos, A. G. (2000) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19960520)50:4<357::aid-bit2>3.0.co;2-k · Cited by 484
Pasche, S., De Paul, S. M., Vörös, J., Spencer, N. D., & Textor, M. (2003) · Langmuir · doi:10.1021/la034111y · Cited by 411
Proteins and cells on PEG immobilized silicon surfaces
Zhang, M., Desai, T., & Ferrari, M. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00026-x · Cited by 408
Drug delivery systems: Advanced technologies potentially applicable in personalized treatments
Coelho, J. F., Ferreira, P. C., Alves, P., Cordeiro, R., Fonseca, A. C., Góis, J. R., & Gil, M. H. (2010) · EPMA Journal · doi:10.1007/s13167-010-0001-x · Cited by 406
Mellott, M. B., Searcy, K., & Pishko, M. V. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00258-1 · Cited by 389
Stability of hydrogels used in cell encapsulation: An in vitro comparison of alginate and agarose
Shoichet, M. S., Li, R. H., White, M. L., & Winn, S. R. (1996) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19960520)50:4<374::aid-bit4>3.0.co;2-i · Cited by 296
Nanoparticles for Imaging, Sensing, and Therapeutic Intervention
Bogart, L. K., Pourroy, G., Murphy, C. J., Puntes, V., Pellegrino, T., Rosenblum, D., Peer, D., & Lévy, R. (2014) · ACS Nano · doi:10.1021/nn500962q · Cited by 295
Effect of the alginate composition on the biocompatibility of alginate-polylysine microcapsules
De Vos, P. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00135-4 · Cited by 274
Hsiao, C.-W., Bai, M.-Y., Chang, Y., Chung, M.-F., Lee, T.-Y., Wu, C.-T., Maiti, B., Liao, Z.-X., Li, R.-K., & Sung, H.-W. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.10.065 · Cited by 269
Huang, N.-P., Vörös, J., De Paul, S. M., Textor, M., & Spencer, N. D. (2002) · Langmuir · doi:10.1021/la010913m · Cited by 268
Hydrogels used for cell‐based drug delivery
Schmidt, J. J., Rowley, J., & Kong, H. J. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32287 · Cited by 228
Drug Delivery Systems: Advanced Technologies Potentially Applicable in Personalised Treatment
(2013) · Advances in Predictive, Preventive and Personalised Medicine · doi:10.1007/978-94-007-6010-3 · Cited by 223
Nuttelman, C. R., Rice, M. A., Rydholm, A. E., Salinas, C. N., Shah, D. N., & Anseth, K. S. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.09.006 · Cited by 223
Challenges and emerging technologies in the immunoisolation of cells and tissues
Wilson, J. T., & Chaikof, E. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.034 · Cited by 198
Immunocompatibility and biocompatibility of cell delivery systems
Řı́hová, B. (2000) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00054-5 · Cited by 174
Quinn, C. P., Pathak, C. P., Heller, A., & Hubbell, J. A. (1995) · Biomaterials · doi:10.1016/0142-9612(95)98856-9 · Cited by 172
Self-citationReceptor-mediated gene transfer vectors: progress towards genetic pharmaceuticals
Molas, M., Gomez-Valades, A., Vidal-Alabro, A., Miguel-Turu, M., Bermudez, J., Bartrons, R., & Perales, J. (2003) · Current Gene Therapy · doi:10.2174/1566523034578195 · Cited by 33
Metadata
- Authors
- Sawhney, A. S., & Hubbell, J. A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1992
- Volume
- 13
- Issue
- 12
- Pages
- 863-870
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2066862080
- Cited by
- 156
- References
- 0
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.