Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 411

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Poly(l-lysine)-graft-poly(ethylene glycol) Assembled Monolayers on Niobium Oxide Surfaces: A Quantitative Study of the Influence of Polymer Interfacial Architecture on Resistance to Protein Adsorption by ToF-SIMS and in Situ OWLS

Pasche, Stéphanie, De Paul, Susan M., Vörös, Janos, Spencer, Nicholas D., Textor, Marcus·2003·Langmuir

Abstract

Poly( l -lysine) grafted with poly(ethylene glycol) (PLL- g -PEG), a polycationic copolymer that is positively charged at neutral pH, spontaneously adsorbs from aqueous solution onto negatively charged surfaces, resulting in the formation of stable polymeric monolayers and rendering the surfaces protein-resistant to a degree related to the PEG surface density. A set of PLL- g -PEG polymers with different architectures was synthesized. The grafting ratio, g, of the polymer, defined as the ratio of the number of lysine monomers to the number of PEG side chains, was systematically varied between 2 and 23, and PEG molecular weights of 1, 2, and 5 kDa were used. The polymers were adsorbed onto niobium oxide-coated substrates, leading to highly different but well-controlled PEG surface densities with maximal values of 0.9, 0.5, and 0.3 chains/nm 2 for the three PEG molecular weights, respectively. Time-of-flight secondary-ion mass spectrometry (ToF-SIMS) was used in conjunction with the in situ optical waveguide lightmode spectroscopy (OWLS) technique to investigate the interface architecture. While ToF-SIMS provided surface-analytical data on the polymeric adlayer, OWLS allowed the quantitative determination of the adsorbed polymer mass. Extremely good correlations were established between the ToF-SIMS data (obtained in UHV) and the in situ OWLS results. The amount of serum adsorbed, determined quantitatively by OWLS, was found to depend systematically on the surface coverage in terms of the ethylene glycol (EG) density, controlled by both PEG molecular weight and grafting ratio, g . Serum adsorption dropped gradually from 590 ng/cm 2 on bare Nb 2 O 5 to <2 ng/cm 2 (=detection limit of the OWLS technique) for EG densities ≥ 20 nm - 2 . The PLL- g -PEG technology shows itself to be an efficient, cost-effective, and robust tool for the immobilization of PEG chains onto metal oxide surfaces. The precise control over PEG surface density across a wide range allows for the production of tailored surfaces with controlled degrees of bio-interactiveness. Such surfaces are expected to have a substantial potential for applications in biomedical and bioanalytical devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la034111y

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 411

Metadata

Authors
Pasche, S., De Paul, S. M., Vörös, J., Spencer, N. D., & Textor, M.
Venue
Langmuir
Published
2003-09-13
Volume
19
Issue
22
Pages
9216-9225
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W2055660637
Cited by
411
References
25
FWCI
13.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Poly(l-lysine)-graft-poly(ethylene glycol) Assembled Monolayers on Niobium Oxide Surfaces: A Quantitative Study of the Influence of Polymer Interfacial Architecture on Resistance to Protein Adsorption by ToF-SIMS and in Situ OWLS. https://app.cochat.ai/papers/10.1021/la034111y
The paper
Pasche, S., De Paul, S. M., Vörös, J., Spencer, N. D., & Textor, M. (2003). Poly(l-lysine)-graft-poly(ethylene glycol) Assembled Monolayers on Niobium Oxide Surfaces: A Quantitative Study of the Influence of Polymer Interfacial Architecture on Resistance to Protein Adsorption by ToF-SIMS and in Situ OWLS. Langmuir. https://doi.org/10.1021/la034111y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.