CoChat

New bioresorbable pin for the reduction of small bony fragments: design, mechanical properties and in vitro degradation

Claes, L.E., Ignatius, A.A., Rehm, K.E., Scholz, C. · 1996 · Biomaterials

The DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.

Abstract

The design, material properties, and in vivo degradation characteristics of a new resorbable pin for the reductions of small bony fragments are described. The Polypin, made of 70:30 poly (L, DL-lactide), had an initial bending strength of 155-163 MPa, as measured by a three-point bending test. Ethylene oxide (EO)- and gamma-sterilization did not substantially affect its initial mechanical properties. The initial molecular weight (Mw) of 523,000 to 600,000, however, decreased 60-75% after gamma-sterilization. Incubation of the EO-sterilized pins in 37 degrees C saline solution produced a complete loss of bending strength at 18 months. An accelerated test at 70 degrees C led to a complete loss of strength after only 96 h. Degradation of the gamma-sterilized pin at 70 degrees C was about 30% faster than that of the EO-sterilized pin. Bending strength and molecular weight were unaffected by storage at room temperature for 46 months. The relatively slow strength loss rate of the Polypin potentially extends the application of resorbable devices to slow-healing fractures. The new pin design allows application of light interfragmentary compression, thus reducing the risk of pin loosening, and an X-ray marker is provided.

Overview

Integrity signals

Registry

Crossref · 10.1016/0142-9612(95)00327-4

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 18 references

Research works printed but not linked: 5

  1. Claes, 1986, Resorbierbare Implantate zur Refixierung von osteochondralen Fragmenten in Gelenkflächen, Akt Traumatol, 16, 74
  2. Greve, 1985, Refixation osteochondraler Fragmente durch resorbierbare Kunststoffstifte, Akt Traumatol, 15, 145
  3. Ruf, 1994, The significance of sterile sinus formation after osteosynthesis using resorbable polyglycolide rods (Biofix), J Bone Joint Surg, 76B, 97
  4. Hoffmann, 1989, Die distale Radiusfraktur, Frakturstabilisierung mit biodegradablen Osteosynthese-Stiften (Biofix), Unfallchirurg, 92, 430
  5. Rehm, 1994, Bericht der Arbeitsgruppe Biodegradable Implantate, Akt Traumatol, 24, 70

Cited by

See all 123

Metadata

Authors
Claes, L. E., Ignatius, A. A., Rehm, K. E., & Scholz, C.
Affiliations
  • Universität Ulm (DE)
  • University of Cologne (DE)
Corresponding author
Claes, L.E.
Venue
Biomaterials
Publisher
Elsevier BV
Published
1996-01
Volume
17
Issue
16
Pages
1621-1626
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2015520003
Cited by
123
References
19
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2021: 4 · 2019: 2 · 2018: 3 · 2016: 4 · 2015: 6 · 2014: 3 · 2013: 2 · 2012: 3
FWCI
2.38
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Biomaterials (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
  • Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
Keywords
poly(L-lactic acid), fracture fixation, flexural strength, in vitro degradation, gamma irradiation sterilization, ethylene oxide sterilization, molecular weight reduction, interfragmentary compression, pin loosening
MeSH terms
Biocompatible Materials, Biodegradation, Environmental, Bone Nails, Equipment Design, Ethylene Oxide, Gamma Rays, Humans, Molecular Weight, Polyesters, Radiography, Radius Fractures, Sterilization, Stress, Mechanical, Tensile Strength

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: New bioresorbable pin for the reduction of small bony fragments: design, mechanical properties and in vitro degradation. https://app.cochat.ai/papers/10.1016/0142-9612(95)00327-4
The paper
Claes, L. E., Ignatius, A. A., Rehm, K. E., & Scholz, C. (1996). New bioresorbable pin for the reduction of small bony fragments: design, mechanical properties and in vitro degradation. Biomaterials. https://doi.org/10.1016/0142-9612(95)00327-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.