In vitro degradation and mechanical properties of PLA-PCL copolymer unit cell scaffolds generated by two-photon polymerization
Open accessAbstract
The manufacture of 3D scaffolds with specific controlled porous architecture, defined microstructure and an adjustable degradation profile was achieved using two-photon polymerization (TPP) with a size of 2 × 4 × 2 mm(3). Scaffolds made from poly(D,L-lactide-co-ɛ-caprolactone) copolymer with varying lactic acid (LA) and ɛ -caprolactone (CL) ratios (LC16:4, 18:2 and 9:1) were generated via ring-opening-polymerization and photoactivation. The reactivity was quantified using photo-DSC, yielding a double bond conversion ranging from 70% to 90%. The pore sizes for all LC scaffolds were see 300 μm and throat sizes varied from 152 to 177 μm. In vitro degradation was conducted at different temperatures; 37, 50 and 65 °C. Change in compressive properties immersed at 37 °C over time was also measured. Variations in thermal, degradation and mechanical properties of the LC scaffolds were related to the LA/CL ratio. Scaffold LC16:4 showed significantly lower glass transition temperature (T g) (4.8 °C) in comparison with the LC 18:2 and 9:1 (see 32 °C). Rates of mass loss for the LC16:4 scaffolds at all temperatures were significantly lower than that for LC18:2 and 9:1. The degradation activation energies for scaffold materials ranged from 82.7 to 94.9 kJ mol(-1). A prediction for degradation time was applied through a correlation between long-term degradation studies at 37 °C and short-term studies at elevated temperatures (50 and 65 °C) using the half-life of mass loss (Time (M1/2)) parameter. However, the initial compressive moduli for LC18:2 and 9:1 scaffolds were 7 to 14 times higher than LC16:4 (see 0.27) which was suggested to be due to its higher CL content (20%). All scaffolds showed a gradual loss in their compressive strength and modulus over time as a result of progressive mass loss over time. The manufacturing process utilized and the scaffolds produced have potential for use in tissue engineering and regenerative medicine applications.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
7 of 58 cited sources checked · 2 supported · 1 flagged · accuracy not yet measured
- Premisecitation
The molecular weight of LA is higher than CL (114.14 and 144.13 g mol -1 for CL and LA respectively).
“This was attributed to the fact that the molecular weight of LA was higher than CL (114.14 and 144.13 g mol -1 for CL and LA respectively [52,53]).”
Quote in the paperSubstantial claim1 of 2 sources checked- cites [52] Li, 2013, Synthesis, characterization and reactivity of single-site aluminium amides bearing benzotriazole phenoxide ligands: catalysis for ring-opening polymerization of lactide and carbon dioxide/propylene oxide coupling, Dalton Trans. source
- cites [53] Heijkants, 2005, Extruder synthesis of a new class of polyurethanes: Polyacylurethanes based on poly(ε-caprolactone) oligomers, Polymer source
Section 3.4, Thermal properties (page unavailable), gives 114.14 g/mol as the molecular mass of an ε-caprolactone monomer. The paper does not give 144.13 g/mol for LA or compare LA’s molecular weight with CL’s, so it supports only the CL value. (LLM, conf=0.88)
Experimental — accuracy not yet measured
- Interpretationcitation
The limited variation in pore sizes between different LC scaffolds meant these small differences would not influence the degradation effect observed.
“However the limited variation in the pore sizes between different LC scaffolds [69,70] meant these small differences would not influence the degradation effect observed.”
Quote in the paperSubstantial claim1 of 2 sources checked- cites [69] Sung, 2004, The effect of scaffold degradation rate on 3D cell growth and angiogenesis, Biomaterials source
- cites [70] Yang, 2001, The design of scaffolds for use in tissue engineering. Part I. Traditional factors, Tissue Eng. source
The indexed passages on pore sizes (FIG. 3, page unavailable) and degradation (Materials, page unavailable) discuss separate topics. A search for pore-size effects on degradation found no passage addressing LC scaffolds or showing that small pore-size differences would not influence the observed degradation effect. (LLM, conf=0.72)
Experimental — accuracy not yet measured
- Rests on an assumption: The surface area/volume ratio of the scaffolds depends on pore size, and the degradation rate of scaffolds is expected to increase as the surface area/volume ratio increases.
- Findingown data
The translation of the STL model to the structure was good and reproducible in terms of pores and throat sizes achieved.
“The translation of the STL model to the structure (see figure 5) was good and reproducible in terms of pores and throat sizes achieved (see table 3).”
Quote in the paperNot a substantial claim - Findingown data
When rating the different compositions in terms of conversion percentage at 30 °C, they followed the order of LC16:4 > 18:2 > 9:1.
“When rating the different compositions in terms of conversion percentage at 30 °C, they followed the order of LC16:4 > 18:2 > 9:1.”
Quote in the paperNot a substantial claim - Findingreasoning
Pore geometry deviated from spherical shape to ellipsoidal with aspect ratio of approximately 1.10 for the produced scaffolds.
“Pore geometry deviated from spherical shape to ellipsoidal with aspect ratio of approximately 1.10 for the produced scaffolds.”
Quote in the paperNot a substantial claim
- Findingown data
The conversion in LC9:1 appeared to be highly dependent on the temperature.
“The conversion in LC9:1 appeared to be highly dependent on the temperature.”
Quote in the paperNot a substantial claim - Findingreasoning
The variants of reactivity in terms tmax were found to be as follows LC18:2 < 16:4 < 9:1 at 30 °C.
“Therefore the variants of reactivity in terms t max were found to be as follows LC18:2 < 16:4 < 9:1 at 30 °C.”
Quote in the paperNot a substantial claim - Findingown data
The results of the synthesis are summarized in table 2 showing correlation with the amounts of educts used, with a deviation of no more than one monomer unit.
“The results of the synthesis are summarized in table 2 showing correlation with the amounts of educts used, with a deviation of no more than one monomer unit.”
Quote in the paperNot a substantial claim - Findingnone given
High temperatures foster the curing process expressed by lower tmax values.
“High temperatures foster the curing process expressed by lower t max values.”
Quote in the paperNot a substantial claim - Findingown data
LC18:2 was less reactive than LC9:1 and LC16:4 for all temperatures.
“LC18:2 was less reactive than LC9:1 and LC16:4 for all temperatures.”
Quote in the paperNot a substantial claim - Findingreasoning
No significant changes were observed in tensile strength and modulus up to 25 kGy for the samples presented here.
“However, no significant changes were observed in tensile strength and modulus up to 25 kGy for the samples presented here.”
Quote in the paperSubstantial claim - Findingreasoning
No significant changes were observed in stress-strain curves for all LC16:4, 18:2 and 9:1 scaffolds post sterilisation.
“No significant changes were observed in stressstrain curves for all LC16:4, 18:2 and 9:1 scaffolds post sterilisation.”
Quote in the paperSubstantial claim - Findingown data
There was no significant difference in tmax of curing for LC9:1 at different temperatures.
“There was no significant difference in t max of curing for LC9:1 at different temperatures, figure 4.”
Quote in the paperNot a substantial claim - Findingreasoning
LC16:4, 18:2 and 9:1 scaffolds maintained their weight change at ~200, 400 and 250% for the duration of the study at 37 °C.
“LC16:4, 18:2 and 9:1 scaffolds maintained their weight change at ~200, 400 and 250% for the duration of the study at 37 °C.”
Quote in the paperNot a substantial claim - Findingreasoning
LC16:4 scaffolds had the highest amount of CL compared to LC18:2 and LC9:1.
“LC16:4 scaffolds had the highest amount of CL compared to LC18:2 and 9:1 consistent with their low weight change and mass loss over the degradation in PBS at different temperatures.”
Quote in the paperSubstantial claim - Findingreasoning
Large deteriorations were observed for LC18:2 and LC9:1 scaffolds, in particular at elevated temperatures.
“Conversely, large deteriorations were observed for LC18:2 and 9:1 scaffolds in particular at elevated temperatures.”
Quote in the paperSubstantial claim - Findingown data
Compressive strengths at 20% strain for LC18:2 and LC9:1 scaffolds (0.2 and 0.55 MPa) were significantly higher (P < 0.001) than LC16:4 (0.05 MPa).
“Compressive strengths at 20% strain for LC18:2 and 9:1 (0.2 and 0.55 MPa) scaffolds were also significantly higher (P < 0.001) than LC16:4 (0.05 MPa).”
Quote in the paperSubstantial claim - Findingnone given
Three dimensional porous scaffolds were manufactured via TPP technology based on a Schwarz Primitive minimal surface derived unit cells with μm resolution and pore size of about 300 μm.
“Three dimensional porous scaffolds were manufactured via a TPP technology based on a Schwarz Primitive minimal surface derived unit cells with μm resolution and pore size of about 300 μm.”
Quote in the paperSubstantial claim - Findingreasoning
Rates of mass loss of LC16:4 scaffolds at 37, 50 and 65 °C were lower than those for LC18:2 and LC9:1 scaffolds.
“Rates of mass loss of LC16:4 scaffolds at 37, 50 and 65 °C were lower than that for LC18:2 and 9:1.”
Quote in the paperSubstantial claim - Findingcitation
The values of activation energy obtained for LC scaffolds using rate of mass loss were similar to the published results for biodegradable polymers.
“The values of activation energy obtained for LC scaffolds using rate of mass loss were similar to the published results for biodegradable polymers [34,40,71].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [34] Pietrzak, 2003, The influence of temperature on the degradation rate of lactosorb copolymer, J. Craniofac. Surg. source
- cites [40] Deng, 2005, Effect of load and temperature on in vitro degradation of poly(glycolide-co-L-lactide) multifilament braids, Biomaterials source
- cites [71] Agrawal, 1997, Elevated temperature degradation of a 50:50 copolymer of PLA-PGA, Tissue Eng. source
- Findingown data
After 20 d, all scaffolds showed decreases in strength and modulus till the end of the study at 83 d.
“After this period all scaffolds showed decreases in strength and modulus till end of the study at 83 d.”
Quote in the paperSubstantial claim - Findingown data
No significant changes (P > 0.05) were seen in both strength and modulus for all scaffolds over 20 d of degradation in PBS at 37 °C.
“No significant changes (P > 0.05) were seen in both strength and modulus for all scaffolds over 20 d of degradation in PBS at 37 °C.”
Quote in the paperSubstantial claim - Findingown data
By fitting plots relating half-life of mass loss to degradation temperature, a power equation was obtained with regression coefficients greater than 0.99.
“By fitting plots relating half-life of mass loss (Time (M 1/2 )), required time for the scaffold to lose 50% of their initial weight, to degradation temperature, a power equation were obtained (see figure 10) and regression coefficients were greater than 0.99.”
Quote in the paperSubstantial claim - Findingown data
The degradation activation energies obtained were 87.9, 82.7 and 94.9 kJ mol−1 for LC16:4, LC18:2 and LC9:1 respectively.
“The degradation activation energies obtained were 87.9, 82.7 and 94.9 kJ mol -1 for LC16:4, LC18:2 and LC9:1 respectively.”
Quote in the paperSubstantial claim - Findingown data
The rate of mass loss for each scaffold type increased as degradation temperature increased from 37 °C to 65 °C.
“Moreover, the rate of mass loss for each scaffold type, determined as the gradient of absolute mass loss versus time, increased as degradation temperature changed from 37 °C to 65 °C.”
- Also stated in: § Conclusions · plain
“accelerated degradation was predictable as the rate of mass loss for all scaffolds increased gradually by increasing degradation temperature from 37 to 65 °C.”
Quote in the paperSubstantial claim - Also stated in: § Conclusions · plain
- Findingown data
For LC16:4 scaffolds, no significant visual changes were detected at different time points and temperatures.
“For LC16:4 scaffolds, no significant visual changes were detected at different time points and temperatures.”
Quote in the paperSubstantial claim - Findingown data
The degradation medium (PBS) remained at neutral pH of 7.3 ± 0.1 for all scaffolds during degradation at 37 and 50 °C due to buffering capability of PBS.
“The degradation medium (PBS) remained at neutral pH of 7.3 ± 0.1 for all scaffolds during degradation at 37 and 50 °C due to buffering capability of PBS (see figures 8(G) and (H)).”
Quote in the paperNot a substantial claim - Findingown data
Mass loss for LC16:4, LC18:2 and LC9:1 scaffolds increased gradually with degradation time at different temperatures.
“Mass loss for LC16:4, 18:2 and 9:1 scaffolds showed a gradual increase of degradation time at different temperatures.”
Quote in the paperSubstantial claim - Findingreasoning
At 65 °C, the pH of PBS for LC18:2 and LC9:1 scaffolds decreased to around 7.0 after 6 d.
“At 65 °C, pH of PBS for LC18:2 and 9:1 scaffolds decreased to be around 7.0 after 6 d (see figure 8 I)”
Quote in the paperNot a substantial claim - Findingown data
The rate of mass loss change for the scaffolds yielded an Arrhenius relationship with regression coefficients greater than 0.99.
“The rate of mass loss change for the scaffolds yielded an Arrhenius relationship with regression coefficients greater than 0.99 (see figure 9).”
Quote in the paperSubstantial claim - Findingown data
The relation between percentage mass loss and degradation time for all scaffolds at 37, 50 and 65 °C followed a linear function with regression coefficient greater than 0.98.
“The relation between percentage of mass loss for all scaffolds and degradation time at 37, 50 and 65 °C followed a linear function with regression coefficient greater than 0.98.”
Quote in the paperSubstantial claim - Findingown data
Before degradation, compressive moduli were 0.27, 2 and 4 MPa for LC16:4, LC18:2 and LC9:2 respectively.
“Before degradation, compressive moduli were see 0.27, 2 and 4 MPa for LC16:4, 18:2 and 9:2 respectively.”
Quote in the paperSubstantial claim - Interpretationown data
The initial increase in wet weight was attributed to fast water uptake till specimens attained saturation.
“The initial increase was attributed to fast water uptake till specimens attained saturation.”
Quote in the paperNot a substantial claim - Interpretationcitation
All compositions had potential for structuring using TPP methodology.
“All compositions had potential for structuring using TPP methodology [55].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [55] Tobita, 1998, Molecular weight distribution formed through chain-length-dependent crosslinking reactions, Macromol. Theory Simul. source
- Rests on an assumption: For two-photon polymerization, only optically transparent materials are suitable, and materials with higher caprolactone contents tend to form optical disturbing crystallites at room temperature.
- Interpretationcitation
The absence of significant changes in stress-strain curves post sterilisation was suggested to be due to the double effects of gamma irradiation, crosslinking and chain scission, as both have opposite impacts on molecular weight and mechanical properties of the polymers.
“This was suggested to be due to the double effects of gamma irradiation, crosslinking and chain scission, as both have opposite impacts on molecular weight and mechanical properties of the polymers [61][62][63].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [61][62][63]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Study design and conductreasoning
High methacrylation (above 85%) was crucial to ensure comparability among the synthesized LC scaffolds throughout the testing.
“High methacrylation (above 85%) was crucial to ensure comparability among the synthesized LC scaffolds throughout the testing.”
Quote in the paperSubstantial claim - Interpretationcitation
The plateau in wet weight of the scaffolds was a result of the balance between water uptake and mass loss.
“This plateau in wet weight of the scaffolds was a result of the balance between water uptake and mass loss [38].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [38] Felfel, 2015, Accelerated in vitro degradation properties of polylactic acid/phosphate glass fibre composites, J. Mater. Sci. source
- Interpretationown data
These peaks were suggested to be due to thermal decomposition of the PLCL copolymers.
“These peaks were suggested to be due to thermal decomposition of the PLCL copolymers.”
Quote in the paperNot a substantial claim - Interpretationnone given
The activation energies for degradation were independent of chain length and composition.
“The activation energies for degradation were independent of chain length and composition.”
Quote in the paperSubstantial claim - Interpretationreasoning
The large deteriorations for LC18:2 and LC9:1 scaffolds were due to fast degradation rates and thermal effects.
“This was due to two reasons; fast degradation rates and thermal effects.”
Quote in the paperSubstantial claim - Interpretationown data
Accelerated degradation was predictable as the rate of mass loss for all scaffolds increased gradually by increasing degradation temperature from 37 to 65 °C.
“accelerated degradation was predictable as the rate of mass loss for all scaffolds increased gradually by increasing degradation temperature from 37 to 65 °C.”
Quote in the paperSubstantial claim - Interpretationown data
The degradation rate of the scaffolds at other degradation temperatures could be anticipated through the obtained fitting equations.
“Therefore, the degradation rate of the scaffolds at other degradation temperatures could be anticipated through the obtained fitting equations.”
Quote in the paperSubstantial claim - Interpretationreasoning
The increase in mass loss over time was attributed to continuous degradation of the scaffold materials.
“This was attributed to continuous degradation of the scaffold materials.”
Quote in the paperSubstantial claim - Interpretationreasoning
The lower mass loss rates of LC16:4 compared to LC18:2 and LC9:1 could be ascribed to variation in LA/CL ratio between the scaffold materials.
“This could be ascribed to the variation in LA/CL ratio between LC16:4, 18:2 and 9:1 scaffold materials (see table 2).”
Quote in the paperSubstantial claim - Interpretationreasoning
Effects of heating-cooling cycles were more significant on LC18:2 and LC9:1 than LC16:4 due to their thermal properties.
“Effects of heating-cooling cycles were more significant on LC18:2 and 9:1 than LC16:4 due to their thermal properties (see figure 7).”
Quote in the paperSubstantial claim - Interpretationnone given
Changes in thermal, degradation and mechanical properties of all scaffolds were related to their chemical composition (LA/CL ratio).
“Changes in thermal, degradation and mechanical properties of all scaffolds were related to their chemical composition (LA/CL ratio)”
Quote in the paperSubstantial claim - Interpretationreasoning
Repeatable heating-cooling cycles during degradation at 37 °C and testing or changing PBS at room temperature (~20 °C) were suggested to accelerate the degradation rate of the scaffolds (thermal effect).
“Repeatable heatingcooling cycles during degradation at 37 °C and testing or changing PBS at room temperature (~20 °C) were suggested to accelerate the degradation rate of the scaffolds (thermal effect).”
Quote in the paperSubstantial claim - Premisecitation
Young's modulus for poly(D,L-lactide) is approximately five times higher than poly(ɛ-caprolactone) alone.
“Young's modulus for poly(D,L-lactide) is approximately five times higher than poly(ɛ-caprolactone) alone [67,68].”
Quote in the paperSubstantial claim0 of 2 sources checked - Interpretationcitation
An increase in CL content would lead to a lower degradation rate.
“Consequently, it was expected that an increase in CL content would lead to a lower degradation rate.”
Quote in the paperSubstantial claim - Premisereasoning
It was not applicable to measure the molecular weight for photo cross-linked copolymers using gel permeation chromatography (GPC) due to their insolubility in organic solvents.
“However, it was not applicable to measure the molecular weight for photo cross-linked copolymers using gel permeation chromatography (GPC) due to their insolubility in organic solvents.”
Quote in the paperSubstantial claim - Interpretationown data
By applying a temperature superposition, a feasible accelerated method was generated to predict long-term degradation time for LC scaffolds at 37 °C.
“By applying a temperature superposition, a feasible accelerated method was generated to predict longterm degradation time for LC scaffolds at 37 °C.”
Quote in the paperSubstantial claim - Interpretationreasoning
The low weight change and mass loss of LC16:4 scaffolds over degradation in PBS at different temperatures are consistent with their highest CL content.
“LC16:4 scaffolds had the highest amount of CL compared to LC18:2 and 9:1 consistent with their low weight change and mass loss over the degradation in PBS at different temperatures.”
Quote in the paperSubstantial claim - Interpretationreasoning
The decrease in pH at 65 °C for LC18:2 and LC9:1 scaffolds was a result of faster release of acidic degradation by-products of poly(L-lactide-coɛ-caprolactone).
“as a result of faster release of acidic degradation by-products of poly(L-lactide-coɛ-caprolactone).”
Quote in the paperNot a substantial claim - Interpretationown data
Reduction in compressive properties for all scaffolds over time was ascribed to continuous degradation of the scaffold materials.
“Reduction in compressive properties for all scaffolds over time was ascribed to continuous degradation of the scaffold materials as can be seen from variations in mass loss against time (see figure 8(D)).”
Quote in the paperSubstantial claim - Interpretationreasoning
Mechanical properties of the copolymer would be expected to decrease as the CL content increased.
“Therefore, mechanical properties of the copolymer would be expected to decrease as the CL content increased as shown in figure 11.”
Quote in the paperSubstantial claim
- May combine two claims. 32
- Classified as probably not a substantial claim. 27
May combine two claims.
PremisecitationRecent approaches managed to create scaffolds bigger than 15 mm3 and offer encouraging preclinical results, underlining the potential of TPP to deliver microstructures of good reproducibility at scale.
“Nevertheless the technology is constantly improving and recent approaches managed to create scaffolds bigger than 15 mm 3 [74,75] and offer encouraging preclinical results [76] underlining the potential of TPP to deliver microstructures of good reproducibility at scale.”
Quote in the paperNot a substantial claim1 of 3 sources checked- cites [74] Hsieh, 2010, 3D microstructured tissue scaffolds fabricated by two-photon laser scanning photolithography, Biomaterials source
- cites [75] Ovsianikov, 2012, Engineering 3D cell-culture matrices: multiphoton processing technologies for biological and tissue engineering applications, Expert Rev. Med. Devices source
- cites [76] Bückmann, 2014, An elasto-mechanical unfeelability cloak made of pentamode metamaterials, Nat. Commun. source
The cited paper’s Numerical calculations section describes a fabricated pentamode cloak microstructure with a total volume of 2 mm³, not a scaffold larger than 15 mm³. The preclinical-results phrase has a separate citation [76] and is not attributed to this source. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationSeveral research groups have investigated the potential of 2PP for biomedical applications with biocompatible resins such as PLA, PCL, PEG or the use of proteins as scaffold material, which have the potential for clinical application.
“Several research groups have been investigated the potential of 2PP for biomedical applications with biocompatible resins such as PLA [28], PCL [29], PEG [30] or the use of proteins as scaffold material [31,32], which have the potential for clinical application [33].”
Quote in the paperNot a substantial claim1 of 3 sources checked- cites [28] Danilevicius, 2015, The effect of porosity on cell ingrowth into accurately defined, laser-made, polylactide-based 3D scaffolds, Appl. Surf. Sci. source
- cites [29] Claeyssens, 2009, 3D Biodegradable Structures Fabricated by Two-Photon Polymerization, Langmuir source
- cites [30] Ovsianikov, 2011, 3D laser micro- and nano-structuring of acrylated poly(ethylene glycol) materials and evaluation of their cytoxicity for tissue engineering applications, Acta Biomater. source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationGamma radiation was preferred as a method of sterilisation due to its high efficiency, high penetration and negligible thermal effects.
“Gamma radiation was preferred as a method of sterilisation due to its high efficiency, high penetration and negligible thermal effects [61].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [61] Cottam, 2009, Effect of sterilisation by gamma irradiation on the ability of polycaprolactone (PCL) to act as a scaffold material, Med. Eng. Phys. source
The Introduction says gamma irradiation is likely to be the method of choice for many PCL implants and is highly penetrative. Section 2.2 describes the dose used to ensure thorough sterilisation, but the paper does not give high efficiency or negligible thermal effects as reasons for preferring it. (LLM, conf=0.88)
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationResolutions of up to 50 μm have been achieved using photo-polymerization techniques for the spatial patterning of materials in a layer-by-layer approach by stereo-lithography.
“Resolutions of up to 50 μm have been achieved using photo-polymerization techniques for the spatial In vitro degradation and mechanical properties of PLA-PCL copolymer unit cell scaffolds generated by two-photon polymerization patterning of materials in a layer-by-layer approach by stereo-lithography [16,17].”
Quote in the paperNot a substantial claim1 of 2 sources checked- cites [16] Stampfl, 2008, Photopolymers with tunable mechanical properties processed by laser-based high-resolution stereolithography, J. Micromech. Microeng. source
- cites [17] Lee, 2007, Poly(propylene fumarate) bone tissue engineering scaffold fabrication using stereolithography: effects of resin formulations and laser parameters, Biomacromolecules source
May combine two claims.
PremisecitationThe required time for complete resorption of PDLLA is approximately 1-2 years, whilst PCL requires 2-4 years.
“It was reported that the required time for complete resorption (degradation time) of poly(D,L-lactide) (PDLLA) is approximately 1-2 years, whilst poly(ɛ-caprolactone) (PCL) requires 2-4 years [1,67,68].”
Quote in the paperSubstantial claim1 of 3 sources checked- cites [1] Woodruff, 2010, The return of a forgotten polymer—Polycaprolactone in the 21st century, Prog. Polym. Sci. source
Section 3 (Biodegradation; page not provided) states that PCL homopolymer takes two to four years to degrade completely, depending on its starting molecular weight. The copy does not give a one-to-two-year complete-resorption time for PDLLA; Section 1 says only that PCL degrades more slowly than poly(D,L-lactide). (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [67] Middleton, 2000, Synthetic biodegradable polymers as orthopedic devices, Biomaterials source
- cites [68] Maurus, 2004, Bioabsorbable implant material review, Oper. Tech. Sports Med. source
May combine two claims.
Findingown dataSEM micrographs revealed a high similarity of structure and consistency with the applied model.
“SEM micrographs revealed a high similarity of structure and consistency with the applied model.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataThe midpoint glass transition temperatures (Tg) for LC16:4, 18:2 and 9:1 were 4.8, 31 and 33 °C respectively.
“The midpoint glass transition temperatures (T g ) for LC16:4, 18:2 and 9:1 were 4.8, 31 and 33 °C respectively.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Findingnone givenThe lower initiation limit of the polymerization with the UV source used appeared to be at 8-9 s, including the time needed for the lamp to develop full power.
“The lower initiation limit of the polymerization with the UV source used appeared to be at 8-9 s, including the time needed for the lamp to develop full power.”
Quote in the paperNot a substantial claimMay combine two claims.
FindingreasoningThe molecular weight results for the LC scaffolds correlated with the monomer incorporation: LC18:2 and 9:1 showed higher values (see 3-5%) than theoretical molecular weights, while LC16:4 had 6% less than the predicted value.
“This also correlated with the molecular weight results obtained for the LC scaffolds, as LC18:2 and 9:1 showed higher values (see 3-5%) than theoretical molecular weights, while LC16:4 had 6% less than the predicted value.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataThe pore sizes for all LC scaffolds were see 300 μm and throat sizes varied from 152 μm (for LC9:1) to 177 μm (for LC16:4 and 18:2).
“The pore sizes for all LC scaffolds were see 300 μm and throat sizes varied from 152 μm (for LC9:1) to 177 μm (for LC16:4 and 18:2), see table 3.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataEndothermic peaks were observed at 281 o C for LC16:4 and 365 °C for LC18:2 and 9:1, and represented decomposition temperature (Td).
“Endothermic peaks were also observed at 281 o C for LC16:4 and 365 °C (see figure 7) for LC18:2 and 9:1, and represented decomposition temperature (T d ).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataInitial increases were seen in the wet weight of LC16:4, 18:2 and 9:1 scaffolds respectively up to 5 (at 37 °C) and 2 d at 50 and 65 °C, followed by stabilisation in weights of all scaffolds.
“Initial increases were seen in the wet weight of LC16:4, 18:2 and 9:1 scaffolds respectively up to 5 (at 37 °C) and 2 d at 50 and 65 °C, followed by stabilisation in weights of all scaffolds.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataThe lactide richer derivatives (9:1 and 18:2) tended to incorporate a lactide unit more than the target value, whereas the caprolactone richer LC16:4 had one LA unit less.
“The lactide richer derivatives (9:1 and 18:2) tended to incorporate a lactide unit more than the target value, whereas the caprolactone richer LC16:4 had one LA unit less.”
Quote in the paperNot a substantial claimMay combine two claims.
FindingreasoningThe temperature dependency was most prominent in LC9:1, resulting in large steps between 30 °C and 70 °C, with a change in ΔH of see 25 J g -1 , compared with a change of <8 J g -1 for the other compositions.
“The temperature dependency was most prominent in LC9:1, resulting in large steps between 30 °C and 70 °C, with a change in ΔH of see 25 J g -1 , compared with a change of <8 J g -1 for the other compositions.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataHeating-cooling cycles covered a range of temperatures (37 °C-20 °C) which was around the glass transition temperature for LC18:2 and LC9:1 scaffolds, whilst Tg of LC16:4 was out of this range.
“Heating-cooling cycles covered a range of temperatures (37 °C-20 °C) which was around their glass transition temperature for LC18:2 and 9:1 scaffolds, whilst T g of LC16:4 was out of this range.”
Quote in the paperSubstantial claimMay combine two claims.
Findingnone givenFor commercialization, the writing time is still the main limitation; manufacturing scaffolds of one cubic centimeter with the current set-up would lead to writing times of about 6 d.
“For commercialization, the writing time is still the main limitation, for example for manufacturing scaffolds of one cubic centimeter with the current set-up would lead to writing times of see 6 d.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationPore sizes were in the ideal range of 200-400 μm, known to facilitate osteo-differentiation and functional bone formation.
“Pore sizes were in the ideal range of 200-400 μm, known to facilitate osteo-differentiation and functional bone formation [12,57,58].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [12] Tse, 2010, Preparation of hydrogel substrates with tunable mechanical properties, Curr Protoc. Cell Biol. source
- cites [57] Papaioannou, 2006, Assessment of vascular wall shear stress and implications for atherosclerotic disease, Int. J. Cardiol. source
- cites [58] Papaioannou, 2005, Vascular wall shear stress: basic principles and methods, Hellenic J. Cardiol.
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationThe long wavelength of the NIR allows for deeper penetration into the material and thus structuring in millimeter dimensions and a submicron resolution.
“The long wavelength of the NIR allows for deeper penetration into the material and thus structuring in millimeter dimensions and a submicron resolution (figure 1(A)) [23][24][25][26][27].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [23][24][25][26][27]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
InterpretationreasoningLC9:1 generated more heat due to the [molecular weight]:[methacryl-group] ratio, resulting in a higher double bond density which correlated with the higher ΔH values.
“LC9:1 generated more heat due to the [molecular weight]:[methacryl-group] ratio, resulting in a higher double bond density which correlated with the higher ΔH values.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim. May combine two claims.
PremisecitationThe main purpose of accelerated degradation studies is to attain degradation profiles within a shorter period of time and descriptive to that obtained at standard degradation conditions.
“The main purpose of accelerated degradation studies is to attain degradation profiles within a shorter period of time and descriptive to that obtained at standard degradation conditions [35].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [35] Lam, 2008, Dynamics of in vitro polymer degradation of polycaprolactone-based scaffolds: accelerated versus simulated physiological conditions, Biomed. Mater. source
May combine two claims.
InterpretationreasoningNo crystallisation or melting peaks were detected for any of the scaffolds, possibly due to the high crosslinking in the photo-polymerisation process.
“No crystallisation or melting peaks were detected for any of the scaffolds, possibly due to the high crosslinking in the photo-polymerisation process.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationIncomplete chain-end-capping with methacrylate groups would consequently affect the mechanical properties, cause local acidification and fast degradation of the LC chains.
“This would consequently affect the mechanical properties, cause local acidification and fast degradation of the LC chains due to the lack of complete chain-end-capping with methacrylate groups [54].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [54] Burdick, 2003, An initial investigation of photocurable 3D lactic acid based scaffolds in a critical-sized cranial defect, Biomaterials source
Classified as probably not a substantial claim.
PremisecitationHigher resolutions can be obtained by using two-photon absorption (TPA) where excitation wavelengths in the near-infrared (NIR) were used in combination with femtosecond pulsed lasers.
“Higher resolutions can be obtained by using two-photon absorption (TPA) where excitation wavelengths in the near-infrared (NIR) were used in combination with femtosecond pulsed lasers [18][19][20].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [18][19][20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Classified as probably not a substantial claim. May combine two claims.
Study design and conductcitationWriting parameters were kept constant for all scaffolds since they can influence the mechanical properties and degradation of the resulting polymer structures.
“Writing parameters were kept constant for all scaffolds since they can influence the mechanical properties and degradation of the resulting polymer structures [59].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [59] Farkas, 2015, Four-order stiffness variation of laser-fabricated photopolymer biodegradable scaffolds by laser parameter modulation, Mater. Sci. Eng. C source
Probably not a substantial claim: may not pass S3 (load-bearing).
InterpretationcitationThe higher temperature dependency of LC9:1 could have been related to the higher amount of double bonds present and the accessibility of these with increase in temperature and subsequent reduction in viscosity.
“This could have been related to the higher amount of double bonds present and the accessibility of these with increase in temperature and subsequent reduction in viscosity [55].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [55] Tobita, 1998, Molecular weight distribution formed through chain-length-dependent crosslinking reactions, Macromol. Theory Simul. source
Classified as probably not a substantial claim.
PremisecitationRelating accelerated degradation at elevated temperatures to 37 °C allows effective fast screening rather than long term studies saving research funds and time.
“Relating accelerated degradation at elevated temperatures to 37 °C allows effective fast screening rather than long term studies saving research funds and time [34].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [34] Pietrzak, 2003, The influence of temperature on the degradation rate of lactosorb copolymer, J. Craniofac. Surg. source
May combine two claims.
InterpretationcitationA second phase of increase in the scaffold weights was seen after 25 and 6 d of degradation at 50 and 65 °C respectively, which was a consequence of imbalance between water uptake and mass loss (i.e. mass loss due to hydrolytic degradation became dominant).
“In contrast, a second phase of increase in the scaffold weights was seen after 25 and 6 d of degradation at 50 and 65 °C respectively, which was a consequence of imbalance between water uptake and mass loss (i.e.mass loss due to hydrolytic degradation became dominant) [38].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [38] Felfel, 2015, Accelerated in vitro degradation properties of polylactic acid/phosphate glass fibre composites, J. Mater. Sci. source
May combine two claims.
Interpretationown dataThe calculations of conversions revealed the high reactivity and large differences between temperatures for LC9:1, which are a result of its incomplete conversion at low temperatures (less than 70%).
“The calculations of conversions revealed the high reactivity and large differences between temperatures for LC9:1, which are a result of its incomplete conversion at low temperatures (less than 70%).”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable).
PremisecitationValidated accelerated degradation studies are an attractive research tool to explore the influence of the physico-chemical factors as well as other influences such as initiators and polymer blends.
“Therefore, validated accelerated degradation studies are an attractive research tool [38] to explore the influence of the physico-chemical factors as well as other influences such as initiators and polymer blends.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [38] Felfel, 2015, Accelerated in vitro degradation properties of polylactic acid/phosphate glass fibre composites, J. Mater. Sci. source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationBody temperature varies significantly between human and certain animals such as pigs and rabbits (approximately 1-3 °C higher than humans) which are commonly used as in vivo models.
“Moreover, body temperature varies significantly between human and certain animals such as pigs and rabbits (approximately 1-3 °C higher than humans) which are commonly used as in vivo models [34].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [34] Pietrzak, 2003, The influence of temperature on the degradation rate of lactosorb copolymer, J. Craniofac. Surg. source
May combine two claims.
InterpretationcitationValues of Tg and Td for LC18:2 and 9:1 were similar, whilst LC16:4 showed significantly lower results, which was ascribed to the variation in D,L lactide ratio to ɛ-caprolactone (LA/CL) ratio in different scaffolds.
“Values of T g and T d for LC18:2 and 9:1were similar, whilst LC16:4 showed significantly lower results, which was ascribed to the variation in D,L lactide ratio to ɛ-caprolactone (LA/CL) ratio in different scaffolds [65,66] (see table 2).”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [65] Fernández, 2013, A new generation of poly(lactide/ε-caprolactone) polymeric biomaterials for application in the medical field, J. Biomed. Mater. Res. A source
- cites [66] Fernández, 2012, Synthesis, structure and properties of poly(L-lactide-co--caprolactone) statistical copolymers, J. Mech. Behav. Biomed. Mater. source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe degradation rate of degradable polymers is controlled by numerous factors such as degree of crystallinity, chemical structure, molecular weight, porosity, surface/volume ratio, manufacturing methods, implantation site, applied load, degradation temperature and pH of the degradation medium.
“The degradation rate of degradable polymers is controlled by numerous factors such as degree of crystallinity, chemical structure, molecular weight, porosity, surface/volume ratio, manufacturing methods, implantation site, applied load, degradation temperature and pH of the degradation medium [34][35][36][37].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [34][35][36]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Probably not a substantial claim: may not pass S3 (load-bearing).
Interpretationnone givenThe deviation of pore geometry from spherical to ellipsoidal was suggested to be due to the refractive stretching of the precursor along Z-direction.
“This was suggested to be due to the refractive stretching of the precursor along Z-direction.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationClaes et al found that PLA pins completely lost their flexural strength after 18 months and 96 h of immersion in NaCl at 37 °C and 70 °C respectively.
“They found that the pins completely lost their flexural strength after 18 months and 96 h of immersion in NaCl at 37 °C and 70 °C respectively.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [39] Claes, 1996, New bioresorbable pin for the reduction of small bony fragments: design, mechanical properties and in vitro degradation, Biomaterials source
May combine two claims.
PremisecitationVariation in the methacrylation could lead to less stable structures, more unsolidified residues in the material and open chain ends after photochemical vitrification.
“Variation in the methacrylation could lead to less stable structures, more unsolidified residues in the material and open chain ends after photochemical vitrification.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [54] Burdick, 2003, An initial investigation of photocurable 3D lactic acid based scaffolds in a critical-sized cranial defect, Biomaterials source
May combine two claims.
Interpretationown dataAt low temperatures the conversion was the lowest for all precursors, an effect reversed at 70 °C, a temperature at which the motility (molecule size) is a function of conversion.
“At low temperatures the conversion was the lowest for all precursors, an effect reversed at 70 °C, a temperature at which the motility (molecule size) is a function of conversion.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
PremisecitationGamma sterilisation is known to induce molecular changes for polymeric materials by chain scission and crosslinking.
“However, gamma sterilisation is known to induce molecular changes for polymeric materials by chain scission and crosslinking [61][62][63].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [61][62][63]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
May combine two claims.
InterpretationreasoningThese materials have the potential to replace state-of-the-art implants and allografts as they can offer slower degradation and softer mechanics and avoid the acidity-burst at degradation compared to LA.
“These materials have the potential to replace state-of-theart implants and allografts as they can offer slower degradation and softer mechanics and avoid the acidity-burst at degradation compared to LA”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductown dataDegradation and compression tests were completed at day 90 and 83 respectively because LC18:2 and 9:1 scaffolds became brittle and difficult to handle for weighing and mechanical testing.
“The degradation and compression tests were completed at day 90 and 83 respectively because the LC18:2 and 9:1 scaffolds became brittle and difficult to handle for weighing and mechanical testing.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenPrevious studies have suggested that degradation activation energies were independent of the geometry and composition of the PLLA-PGA copolymers.
“Previous studies have suggested that degradation activation energies were independent of the geometry and composition of the PLLA-PGA copolymers.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
PremisecitationAccelerated degradation tests can be afforded an expectation of degradation profiles in a short period of time by correlating the results of the 70 °C test with that obtained at 37 °C.
“It was concluded that accelerated degradation tests can be afforded an expectation of degradation profiles in a short period of time by correlating the results of the 70 °C test with that obtained at 37 °C.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [39] Claes, 1996, New bioresorbable pin for the reduction of small bony fragments: design, mechanical properties and in vitro degradation, Biomaterials source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationA rapid loss of tensile strength was seen for PGLA multifilament braids degraded at higher temperatures.
“A rapid loss of tensile strength was seen for specimens degraded at higher temperatures.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [40] Deng, 2005, Effect of load and temperature on in vitro degradation of poly(glycolide-co-L-lactide) multifilament braids, Biomaterials source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationPietrzak et al. applied the Arrhenius equation to change in inherent viscosity for a 82%PLLA-18%PGA copolymer and obtained an activation energy of 100.1 kJ mol−1.
“Pietrzak et al [34] applied the Arrhenius equation to change in inherent viscosity for a 82%PLLA-18%PGA copolymer and obtained an activation energy of 100.1 kJ”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [34] Pietrzak, 2003, The influence of temperature on the degradation rate of lactosorb copolymer, J. Craniofac. Surg. source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationWeir et al. and Agrawal et al. determined activation energies for 50%PLA-50%PGA copolymer and PLLA (113.9 and 100.5 kJ mol−1) through the change in molecular weight against degradation temperature.
“Weir et al [49] and Agrawal et al [71] determined activation energies for 50%PLA-50%PGA copolymer and PLLA (113.9 and 100.5 kJ mol -1 ) through the change in molecular weight against degradation temperature.”
Quote in the paperNot a substantial claim0 of 2 sources checkedMay combine two claims.
Interpretationown dataMechanical properties of these scaffolds were mainly dependent on their material composition (LA/CL ratio) as all scaffolds have almost the same porosity and pore sizes.
“Mechanical prop-erties of these scaffolds were mainly dependent on their material composition (i.e.LA/CL ratio) as all scaffolds have almost the same porosity and pore sizes.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationThe time required to reach a given breaking strength at different temperature followed an Arrhenius equation and the activation energies calculated were 96.12 to 102.38 kJ mol -1.
“The time required to reach a given breaking strength at different temperature followed an Arrhenius equation and the activation energies calculated were 96.12 to 102.38 kJ mol -1 .”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [40] Deng, 2005, Effect of load and temperature on in vitro degradation of poly(glycolide-co-L-lactide) multifilament braids, Biomaterials source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationArrhenius relation has been conducted for the change in several parameters of biodegradable polymers such as molecular weight, breaking strength, viscosity and mass loss.
“Arrhenius relation has been conducted for the change in several parameters of biodegradable polymers such as molecular weight, breaking strength, viscosity and mass loss [34,38,49,71,72].”
Quote in the paperNot a substantial claim0 of 5 sources checked- cites [34] Pietrzak, 2003, The influence of temperature on the degradation rate of lactosorb copolymer, J. Craniofac. Surg. source
- cites [38] Felfel, 2015, Accelerated in vitro degradation properties of polylactic acid/phosphate glass fibre composites, J. Mater. Sci. source
- cites [49] Weir, 2004, Degradation of poly-L-lactide. Part 2: increased temperature accelerated degradation, Proc. Inst. Mech. Eng. H source
- cites [71] Agrawal, 1997, Elevated temperature degradation of a 50:50 copolymer of PLA-PGA, Tissue Eng. source
- cites [72] Deng, 2008, A study on in vitro degradation behavior of a poly(glycolide-co-l-lactide) monofilament, Acta Biomater. source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationDegradation activation energy was also determined for 10%PLLA-90%PGA through change in tensile breaking strength during degradation at different temperatures, and the activation energy ranged between 95.9 and 102.6 kJ mol−1.
“Degradation activation energy was also determined for 10%PLLA-90%PGA through change in tensile breaking strength during degradation at different temperatures [40].The activation energy ranged between 95.9 kJ mol -1 and 102.6 kJ mol -1 .”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [40] Deng, 2005, Effect of load and temperature on in vitro degradation of poly(glycolide-co-L-lactide) multifilament braids, Biomaterials source
May combine two claims.
PremisecitationTensile modulus and strength of the copolymer films decreased from 1343 to 12 MPa and from 26.6 to 17.2 MPa respectively as the CL contents increased from 10 to 30%.
“Tensile modulus and strength of the copolymer films decreased from 1343 to 12 MPa and from 26.6 to 17.2 MPa respectively as the CL contents increased from 10 to 30%.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [66] Fernández, 2012, Synthesis, structure and properties of poly(L-lactide-co--caprolactone) statistical copolymers, J. Mech. Behav. Biomed. Mater. source
May combine two claims.
Interpretationown dataThe onset glass transition for LC16:4 scaffolds (-1.6 ± 1 °C) was significantly lower than the testing temperature, and this explained the lower variation in results showing a smooth and gradual decrease in their compressive modulus and strength properties.
“The onset glass transition for LC16:4 scaffolds (-1.6 ± 1 °C) was significantly lower than the testing temperature and this explained the lower variation in results showing a smooth and gradual decrease in their compressive modulus and strength properties (inset, figures 11 (A) and (B)).”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationSimilar findings were published for poly(L-lactide-co-ε-caprolactone) copolymers by Fernandez et al.
“Similar findings were published for poly(L-lactide-co-ε-caprolactone) copolymers by Fernandez et al [66].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [66] Fernández, 2012, Synthesis, structure and properties of poly(L-lactide-co--caprolactone) statistical copolymers, J. Mech. Behav. Biomed. Mater. source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationTensile strength of PGLA braids decreased by ~10% after soaking in PBS for 10 d at 47.5 °C, whereas 30 d were required to reach 10% loss in the strength at 37 °C.
“Tensile strength of the braids decreased by ~10% after soaking in PBS for 10 d at 47.5 °C.However, 30 d were required to reach 10% loss in the strength at 37 °C.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [40] Deng, 2005, Effect of load and temperature on in vitro degradation of poly(glycolide-co-L-lactide) multifilament braids, Biomaterials source
The paper relies on this without support.
Complex architectures with specifically controlled micro- and macro-scale features are difficult to achieve using traditional scaffold fabrication techniques.
“However, complex architectures with specifically controlled micro-and macro-scale features have been difficult to achieve.”
The paper relies on this without support.
The rate of hydrolysis of biodegradable polymers increases with degradation temperature, making correlation between short-term high-temperature and long-term physiological-temperature degradation achievable.
“The rate of hydrolysis is known to increase with degradation temper ature which would potentially make the correlation between short-term effects at high temperature and long-term effects at physiological temperature achievable.”
The paper relies on this without support.
Degradable devices can take up to several years for complete degradation at physiological temperature (37 °C), depending on the polymer and geometry.
“Depending on the polymer and geometry, degradable devices can take up to several years for complete degradation at physiological temperature (37 °C).”
The paper relies on this without support.
Schwarz Primitive minimal surface derived unit cells potentially have higher load-bearing capacities due to their strain distribution.
“The 3D scaffold structures were based on a Schwarz Primitive (P) minimal surface derived unit cells which potentially have higher loadbearing capacities due to their strain distribution.”
The paper relies on this without support.
For two-photon polymerization, only optically transparent materials are suitable, and materials with higher caprolactone contents tend to form optical disturbing crystallites at room temperature.
“For TPP, only optical transparent materials are suitable and materials with higher caprolactone contents tending to form optical disturbing crystallites at room temperature.”
The paper relies on this without support.
The relative monomer contents of LC render the polymer more hydrophilic or hydrophobic and influence the degradation rate, viscosity of the precursor, mechanical behavior of the cross-linked and solidified material and degradation behaviour.
“Their relative monomer contents render the polymer more hydrophilic or hydrophobic and influence the degradation rate, viscosity of the precursor and mechanical behavior of the cross-linked and solidified material and degradation behaviour.”
The paper relies on this without support.
The surface area/volume ratio of the scaffolds depends on pore size, and the degradation rate of scaffolds is expected to increase as the surface area/volume ratio increases.
“Note the surface area/ volume ratio of the scaffolds depends on pore size and the degradation rate of scaffolds is expected to increase as the surface area/volume ratio increased.”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Reported pore aspect ratios exceed their defined maximum
MinorThe paper defines pore aspect ratio as the minor axis divided by the major axis, which cannot exceed 1. Table 3 reports values above 1 for every scaffold type.
“Aspect ratios of the pores, the ratio of minor to major axes of the pore, were also determined.”
“| LC16:4 | 314 ± 14 | 177 ± 7 | 1.07 ± 0.03 | | LC18:2 | 328 ± 26 | 177 ± 10 | 1.10 ± 0.05 | | LC9:1 | 290 ± 25 | 152 ± 7 | 1.2 ± 0.05 |”
Compression-test standard points to the wrong reference
MinorThe methods cite reference 51 for the ASTM compression-test standard, but reference 51 is a chemistry paper; the ASTM standard appears as reference 50.
“The compressive strength and modulus were determined using a Hounsfield testing machine and the calculations were done according to the standard ASTM 1621-10:2010 [51] at 25 ± 1 °C.”
“51. Li C-Y, Liu D-C and Ko B-T 2013 Synthesis, characterization and reactivity of single-site aluminium amides bearing benzotriazole phenoxide ligands: catalysis for ring-opening polymerization of lactide and carbon dioxide/propylene oxide coupling Dalton Trans. 42 11488-96”
Activation-energy units disagree within the paper
MinorThe methods assign activation energy units containing inverse kelvin, but the results report activation energies without that temperature dimension.
“E a is the activation energy (J K -1 mol -1 ), R is universal gas constant (J K -1 mol -1 )”
“The degradation activation energies obtained were 87.9, 82.7 and 94.9 kJ mol -1 for LC16:4, LC18:2 and LC9:1 respectively.”
A modulus value is assigned to an unlisted scaffold composition
MinorThe initial compressive-modulus statement assigns the third value to LC9:2, whereas the study identifies that scaffold as LC9:1.
“Before degradation, compressive moduli were see 0.27, 2 and 4 MPa for LC16:4, 18:2 and 9:2 respectively.”
“The changes in compressive modulus and strength of LC16:4, 18:2 and 9:1 scaffolds against time during degradation in PBS at 37 °C are shown in figure 11.”
Cites
Scaffolds in tissue engineering bone and cartilage
Hutmacher, D. W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00121-6 · Cited by 5,002 · see citing works
Lutolf, M. P., & Hubbell, J. A. (2005) · Nature Biotechnology · doi:10.1038/nbt1055 · Cited by 4,551 · see citing works
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033 · see citing works
Finer features for functional microdevices
Kawata, S., Sun, H.-B., Tanaka, T., & Takada, K. (2001) · Nature · doi:10.1038/35089130 · Cited by 2,871 · see citing works
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741 · see citing works
The design of scaffolds for use in tissue engineering. Part I. Traditional factors
Yang, S., Leong, K.-F., Du, Z., & Chua, C.-K. (2001) · Tissue Engineering · doi:10.1089/107632701753337645 · Cited by 2,234 · see citing works
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206 · see citing works
Ultrafast lasers—reliable tools for advanced materials processing
Sugioka, K., & Cheng, Y. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.30 · Cited by 1,545 · see citing works
Bioactive modification of poly (ethylene glycol) hydrogels for tissue engineering
Zhu, J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.044 · Cited by 1,457 · see citing works
Preparation of Hydrogel Substrates with Tunable Mechanical Properties
Tse, J. R., & Engler, A. J. (2010) · Current Protocols in Cell Biology · doi:10.1002/0471143030.cb1016s47 · Cited by 1,070 · see citing works
The effect of scaffold degradation rate on three-dimensional cell growth and angiogenesis
Sung, H.-J., Meredith, C., Johnson, C., & Galis, Z. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.066 · Cited by 804 · see citing works
Direct writing by way of melt electrospinning
Brown, T. D., Dalton, P. D., & Hutmacher, D. W. (2011) · Advanced Materials · doi:10.1002/adma.201103482 · Cited by 800 · see citing works
Electrospinning for tissue engineering scaffolds
Lannutti, J., Reneker, D., Ma, T., Tomasko, D., & Farson, D. (2007) · Materials Science and Engineering: C · doi:10.1016/j.msec.2006.05.019 · Cited by 693 · see citing works
Landers, R., Hübner, U., Schmelzeisen, R., & Mülhaupt, R. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00139-4 · Cited by 627 · see citing works
An elasto-mechanical unfeelability cloak made of pentamode metamaterials
Bückmann, T., Thiel, M., Kadic, M., Schittny, R., & Wegener, M. (2014) · Nature Communications · doi:10.1038/ncomms5130 · Cited by 623 · see citing works
Biological evaluation of medical devices
(2015) · doi:10.3403/00330215u · Cited by 574 · see citing works
(2005) · PubMed · Cited by 567 · see citing works
Complex micromachines produced and driven by light
Galajda, P., & Ormos, P. (2001) · Applied Physics Letters · doi:10.1063/1.1339258 · Cited by 565 · see citing works
Three-dimensional tissue fabrication
Tsang, V. L., & Bhatia, S. N. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.05.001 · Cited by 522 · see citing works
Preparation of porous scaffolds by using freeze-extraction and freeze-gelation methods
Ho, M.-H., Kuo, P.-Y., Hsieh, H.-J., Hsien, T.-Y., Hou, L.-T., Lai, J.-Y., & Wang, D.-M. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00483-6 · Cited by 484 · see citing works
Lam, C. X. F., Savalani, M. M., Teoh, S.-H., & Hutmacher, D. W. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034108 · Cited by 444 · see citing works
Ultrafast laser nanostructuring of photopolymers: a decade of advances
Malinauskas, M., Farsari, M., Piskarskas, A., & Juodkazis, S. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.07.005 · Cited by 431 · see citing works
Recent progress in multiphoton microfabrication
Maruo, S., & Fourkas, J. T. (2008) · Laser & Photonics Reviews · doi:10.1002/lpor.200710039 · Cited by 390 · see citing works
Lee, K.-W., Wang, S., Fox, B. C., Ritman, E. L., Yaszemski, M. J., & Lu, L. (2007) · Biomacromolecules · doi:10.1021/bm060834v · Cited by 292 · see citing works
Bioabsorbable implant material review
Maurus, P. B., & Kaeding, C. C. (2004) · Operative Techniques in Sports Medicine · doi:10.1053/j.otsm.2004.07.015 · Cited by 280 · see citing works
Stampfl, J., Baudis, S., Heller, C., Liska, R., Neumeister, A., Kling, R., Ostendorf, A., & Spitzbart, M. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/12/125014 · Cited by 246 · see citing works
Kinetics and Time−Temperature Equivalence of Polymer Degradation
Lyu, Schley, J., Loy, B., Lind, D., Hobot, C., Sparer, R., & Untereker, D. (2007) · Biomacromolecules · doi:10.1021/bm070313n · Cited by 237 · see citing works
The use of accelerated ageing procedures to predict the long term strength of GRC composites
Litherland, K. L., Oakley, D. R., & Proctor, B. A. (1981) · Cement and Concrete Research · doi:10.1016/0008-8846(81)90117-4 · Cited by 235 · see citing works
Ovsianikov, A., Malinauskas, M., Schlie, S., Chichkov, B., Gittard, S., Narayan, R., Löbler, M., Sternberg, K., Schmitz, K.-P., & Haverich, A. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.10.023 · Cited by 234 · see citing works
Fernández, J., Etxeberria, A., & Sarasua, J.-R. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.01.003 · Cited by 217 · cited 2× · see citing works
“Similar findings were published for poly(L-lactide-co-ε-caprolactone) copolymers by Fernandez et al [66].”
BackgroundResultYe, Q., Spencer, P., Wang, Y., et al. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30890 · Cited by 198 · see citing works
Biomimetic Collagen Scaffolds for Human Bone Cell Growth and Differentiation
Yang, X., BHATNAGAR, R. S., Li, S., et al. (2004) · Tissue Engineering · doi:10.1089/ten.2004.10.1148 · Cited by 192 · see citing works
Scaffolds in tissue engineering bone and cartilage
Hutmacher, D. W. (2000) · Elsevier eBooks · doi:10.1016/b978-008045154-1.50021-6 · Cited by 190 · see citing works
Three-Dimensional Biodegradable Structures Fabricated by Two-Photon Polymerization
Claeyssens, F., Hasan, E. A., Gaidukeviciute, A., Achilleos, D. S., Ranella, A., Reinhardt, C., Ovsianikov, A., Shizhou, X., Fotakis, C., Vamvakaki, M., et al. (2009) · Langmuir · doi:10.1021/la803803m · Cited by 187 · see citing works
Degradation of poly-L-lactide. Part 1: in vitro and in vivo physiological temperature degradation
Weir, N. A., Buchanan, F., Orr, J. F., & Dickson, G. R. (2004) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/0954411041932782 · Cited by 182 · see citing works
Bone tissue engineering: from bench to bedside
Woodruff, M. A., Lange, C., Reichert, J., Berner, A., Chen, F., Fratzl, P., Schantz, J.-T., & Hutmacher, D. W. (2012) · Materials Today · doi:10.1016/s1369-7021(12)70194-3 · Cited by 182 · see citing works
Degradation of poly-L-lactide. Part 2: increased temperature accelerated degradation
Weir, N. A., Buchanan, F. J., Orr, J. F., Farrar, D. F., & Dickson, G. R. (2004) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411041932809 · Cited by 171 · see citing works
Brown, T. D., Edin, F., Detta, N., Skelton, A. D., Hutmacher, D. W., & Dalton, P. D. (2014) · Materials Science and Engineering: C · doi:10.1016/j.msec.2014.07.034 · Cited by 170 · see citing works
Ovsianikov, A., Mironov, V., Stampfl, J., & Liska, R. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.48 · Cited by 160 · see citing works
Mačiulaitis, J., Deveikytė, M., Rekštytė, S., Bratchikov, M., Darinskas, A., Šimbelytė, A., Daunoras, G., Laurinavičienė, A., Laurinavičius, A., Gudas, R., et al. (2015) · Biofabrication · doi:10.1088/1758-5090/7/1/015015 · Cited by 150 · see citing works
WANG, S., Lu, L., Gruetzmacher, J. A., Currier, B. L., & Yaszemski, M. J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.013 · Cited by 147 · see citing works
Photoinitiated crosslinked degradable copolymer networks for tissue engineering applications
Davis, K. A., Burdick, J. A., & Anseth, K. S. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00582-3 · Cited by 142 · see citing works
Malinauskas, M., Danilevičius, P., & Juodkazis, S. (2011) · Optics Express · doi:10.1364/oe.19.005602 · Cited by 134 · see citing works
Assessment of vascular wall shear stress and implications for atherosclerotic disease
Papaioannou, T. G., Karatzis, E. N., Vavuranakis, M., Lekakis, J. P., & Stefanadis, C. (2006) · International Journal of Cardiology · doi:10.1016/j.ijcard.2006.03.035 · Cited by 126 · see citing works
Claes, L. E., Ignatius, A. A., Rehm, K. E., & Scholz, C. (1996) · Biomaterials · doi:10.1016/0142-9612(95)00327-4 · Cited by 123 · see citing works
Weiß, T., Hildebrand, G., Schade, R., & Liefeith, K. (2009) · Engineering in Life Sciences · doi:10.1002/elsc.200900002 · Cited by 121 · see citing works
Self-citationElevated temperature degradation of a 50:50 copolymer of PLA-PGA
Agrawal, C. M., Huang, D., Schmitz, J. P., & Athanasiou, K. A. (1997) · Tissue Engineering · doi:10.1089/ten.1997.3.345 · Cited by 120 · see citing works
Danilevicius, P., Georgiadi, L., Pateman, C. J., Claeyssens, F., Chatzinikolaidou, M., & Farsari, M. (2015) · Applied Surface Science · doi:10.1016/j.apsusc.2014.06.012 · Cited by 117 · see citing works
Cottam, E., Hukins, D. W. L., Lee, K., Hewitt, C., & Jenkins, M. J. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.07.005 · Cited by 110 · see citing works
Burdick, J. A., Frankel, D., Dernell, W. S., & Anseth, K. S. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00538-0 · Cited by 102 · see citing works
Cai, L., & Wang, S. (2009) · Polymer · doi:10.1016/j.polymer.2009.11.042 · Cited by 92 · see citing works
Irradiation effects on polycaprolactone
Narkis, M., Sibony-Chaouat, S., Siegmann, A., Shkolnik, S., & Bell, J. P. (1985) · Polymer · doi:10.1016/0032-3861(85)90056-4 · Cited by 86 · see citing works
Photopolymerization monitoring of ceramic stereolithography resins by FTIR methods
Wu, K. C., & Halloran, J. W. (2005) · Journal of Materials Science · doi:10.1007/s10853-005-5689-y · Cited by 82 · see citing works
Two-photon polymerization of biocompatible photopolymers for microstructured 3D biointerfaces
Weiß, T., Schade, R., Laube, T., Berg, A., Hildebrand, G., Wyrwa, R., Schnabelrauch, M., & Liefeith, K. (2011) · Advanced Engineering Materials · doi:10.1002/adem.201080090 · Cited by 80 · see citing works
Self-citationAugustine, R., Saha, A., Jayachandran, V. P., Thomas, S., & Kalarikkal, N. (2015) · International Journal of Polymeric Materials and Polymeric Biomaterials · doi:10.1080/00914037.2014.977900 · Cited by 78 · see citing works
Hsieh, T. M., Benjamin Ng, C. W., Narayanan, K., Wan, A. C. A., & Ying, J. Y. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.06.029 · Cited by 77 · see citing works
Deng, M., Zhou, J., Chen, G., Burkley, D., Xu, Y., Jamiolkowski, D., & Barbolt, T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.067 · Cited by 75 · see citing works
Accelerated in vitro degradation properties of polylactic acid/phosphate glass fibre composites
Felfel, R. M., Hossain, K. M. Z., Parsons, A. J., Rudd, C. D., & Ahmed, I. (2015) · Journal of Materials Science · doi:10.1007/s10853-015-8946-8 · Cited by 61 · see citing works
Self-citationLi, C.-Y., Liu, D.-C., & Ko, B.-T. (2013) · Dalton Transactions · doi:10.1039/c3dt51003d · Cited by 47 · see citing works
Malinauskas, M., Purlys, V., Rutkauskas, M., Gaidukevičiūtė, A., & Gadonas, R. A. (2010) · Lithuanian Journal of Physics · doi:10.3952/lithjphys.50203 · Cited by 45 · see citing works
Fernández, J., Larrañaga, A., Etxeberria, A., Wang, W., & Sarasua, J. R. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35036 · Cited by 45 · see citing works
Turunen, S., Käpylä, E., Terzaki, K., Viitanen, J., Fotakis, C., Kellomäki, M., & Farsari, M. (2011) · Biofabrication · doi:10.1088/1758-5082/3/4/045002 · Cited by 45 · see citing works
The influence of temperature on the degradation rate of lactosorb copolymer
Pietrzak, W. S., Kumar, M., & Eppley, B. L. (2003) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200303000-00008 · Cited by 44 · see citing works
A study on in vitro degradation behavior of a poly(glycolide-co-l-lactide) monofilament
Deng, M., Chen, G., Burkley, D., Zhou, J., Jamiolkowski, D., Xu, Y., & Vetrecin, R. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.03.011 · Cited by 41 · see citing works
Lee, S., Lee, J. H., & Cho, Y. (2014) · Tissue Engineering and Regenerative Medicine · doi:10.1007/s13770-014-0067-y · Cited by 39 · see citing works
Sie, Y. D., Li, Y.-C., Chang, N., et al. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.000480 · Cited by 34 · see citing works
Cai, L., & Wang, S. (2009) · Biomacromolecules · doi:10.1021/bm901237t · Cited by 33 · see citing works
Berg, A., Wyrwa, R., Weisser, J., Weiss, T., Schade, R., Hildebrand, G., Liefeith, K., Schneider, B., Ellinger, R., & Schnabelrauch, M. (2011) · Advanced Engineering Materials · doi:10.1002/adem.201080092 · Cited by 33 · see citing works
Self-citationEmbroidered and surface coated polycaprolactone-co-lactide scaffolds
Rentsch, B., Bernhardt, R., Scharnweber, D., et al. (2012) · Biomatter · doi:10.4161/biom.21931 · Cited by 30 · see citing works
Lovestead, T. M., Burdick, J. A., Anseth, K. S., et al. (2005) · Polymer · doi:10.1016/j.polymer.2005.03.112 · Cited by 29 · see citing works
Radiation sterilization — evaluation of a new approach for substantiation of 25 kGy
Kowalski, J. B., Aoshuang, Y., & Tallentire, A. (2000) · Radiation Physics and Chemistry · doi:10.1016/s0969-806x(99)00354-0 · Cited by 25 · see citing works
Farkas, B., Romano, I., Ceseracciu, L., Diaspro, A., Brandi, F., & Beke, S. (2015) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.05.054 · Cited by 24 · see citing works
Heijkants, R. G. J. C., Schwab, L. W., van Calck, R. V., de Groot, J. H., Pennings, A. J., & Schouten, A. J. (2005) · Polymer · doi:10.1016/j.polymer.2005.06.089 · Cited by 21 · see citing works
Oliveira, L. M., Araujo, P. L. B., & Araujo, E. S. (2012) · Materials Research · doi:10.1590/s1516-14392012005000173 · Cited by 15 · see citing works
Molecular weight distribution formed through chain-length-dependent crosslinking reactions
Tobita, H. (1998) · Macromolecular Theory and Simulations · doi:10.1002/(sici)1521-3919(19980301)7:2
Complex micromachines produced and driven by light
Galajda, P., & Ormos, P. (n.d.) · Summaries of Papers Presented at the Lasers and Electro-Optics. CLEO '02. Technical Diges · doi:10.1109/cleo.2002.1034415
Biomimetic Collagen Scaffolds for Human Bone Cell Growth and Differentiation
Yang, X. B., Bhatnagar, R. S., Li, S., et al. (2004) · Tissue Engineering · doi:10.1089/1076327041887871
Molecular weight distribution formed through chain-length-dependent crosslinking reactions
Tobita, H. (1998) · Macromolecular Theory and Simulations · doi:10.1002/mats.1998.040070205
Flagged first, then by citations
Cited by
Sorted by citations
Multifunctional Mechanical Metamaterials Based on Triply Periodic Minimal Surface Lattices
Al‐Ketan, O., & Al‐Rub, R. K. A. (2019) · Advanced Engineering Materials · doi:10.1002/adem.201900524 · Cited by 907 · see citing works
PEG-PCL-based nanomedicines: A biodegradable drug delivery system and its application
Grossen, P., Witzigmann, D., Sieber, S., & Huwyler, J. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.05.028 · Cited by 503 · see citing works
Fabrication of Biomedical Scaffolds Using Biodegradable Polymers.
Kirillova, A., Yeazel, T. R., Asheghali, D., Petersen, S. R., Dort, S., Gall, K., & Becker, M. L. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01200 · Cited by 368 · see citing works
Characterization of printed PLA scaffolds for bone tissue engineering
Grémare, A., Gudurić, V., Bareille, R., Héroguez, V., Latour, S., L’Heureux, N., Fricain, J., Catros, S., & Nihouannen, D. L. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36289 · Cited by 363 · see citing works
Sustainable advances in SLA/DLP 3D printing materials and processes
Maines, E. M., Porwal, M. K., Ellison, C. J., et al. (2021) · Green Chemistry · doi:10.1039/d1gc01489g · Cited by 362 · see citing works
Advances in additive manufacturing for bone tissue engineering scaffolds
Madrid, A. P. M., Vrech, S. M., Sánchez, M. A., & Rodríguez, A. P. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.03.037 · Cited by 307 · see citing works
Microarchitected Stretching‐Dominated Mechanical Metamaterials with Minimal Surface Topologies
Al‐Ketan, O., Rezgui, R., Rowshan, R., Du, H., Fang, N. X., & Al‐Rub, R. K. A. (2018) · Advanced Engineering Materials · doi:10.1002/adem.201800029 · Cited by 251 · see citing works
Yang, T., Hu, Y., Wang, C., & Binks, B. P. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b05012 · Cited by 198 · see citing works
High internal phase Pickering emulsions
Rodriguez, A. M. B., & Binks, B. P. (2021) · Current Opinion in Colloid & Interface Science · doi:10.1016/j.cocis.2021.101556 · Cited by 138 · see citing works
A glimpse of biodegradable polymers and their biomedical applications
Shah, T. V., & Vasava, D. V. (2019) · e-Polymers · doi:10.1515/epoly-2019-0041 · Cited by 126 · see citing works
Engineered 3D Polymer and Hydrogel Microenvironments for Cell Culture Applications
Fan, D., Staufer, U., & Accardo, A. (2019) · Bioengineering · doi:10.3390/bioengineering6040113 · Cited by 104 · see citing works
Three-dimensional-printed gas dynamic virtual nozzles for x-ray laser sample delivery
Nelson, G., Kirian, R. A., Weierstall, U., et al. (2016) · Optics Express · doi:10.1364/oe.24.011515 · Cited by 92 · see citing works
Design of copolymer PLA-PCL electrospun matrix for biomedical applications
Pisani, S., Dorati, R., Conti, B., Modena, T., Bruni, G., & Genta, I. (2018) · Reactive and Functional Polymers · doi:10.1016/j.reactfunctpolym.2018.01.011 · Cited by 90 · see citing works
Multiphoton Lithography as a Promising Tool for Biomedical Applications
Gréant, C., Durme, B. V., Hoorick, J. V., & Vlierberghe, S. V. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202212641 · Cited by 86 · see citing works
3D Printing for the Clinic: Examining Contemporary Polymeric Biomaterials and Their Clinical Utility
Weems, A. C., Pérez‐Madrigal, M. M., Arno, M. C., & Dove, A. P. (2020) · Biomacromolecules · doi:10.1021/acs.biomac.9b01539 · Cited by 88 · see citing works
Ju, J., Gu, Z., Liu, X., et al. (2019) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2019.10.085 · Cited by 87 · see citing works
Study on the properties of PLA/PBAT composite modified by nanohydroxyapatite
Yan, D., Wang, Z., Guo, Z., Ma, Y., Wang, C., Tan, H., & Zhang, Y. (2020) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2020.08.062 · Cited by 81 · see citing works
Development of Novel 3-D Printed Scaffolds With Core-Shell Nanoparticles for Nerve Regeneration
Lee, S., Zhu, W., Heyburn, L., Nowicki, M. A., Harris, B. T., & Zhang, L. G. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2558493 · Cited by 82 · see citing works
“hybrid organic-inorganic materials [26], PLGA [27] or the use of ECM proteins [28].”
BackgroundChalanqui, M. J., Pentlavalli, S., McCrudden, C. M., et al. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.09.003 · Cited by 68 · see citing works
Walker, J. M., Bodamer, E., Krebs, O., Luo, Y., Kleinfehn, A. P., Becker, M. L., & Dean, D. (2017) · Biomacromolecules · doi:10.1021/acs.biomac.7b00146 · Cited by 65 · see citing works
Johari, N., Khodaei, A., Samadikuchaksaraei, A., Reis, R. L., Kundu, S. C., & Moroni, L. (2022) · Acta Biomaterialia · doi:10.1016/j.actbio.2022.09.030 · Cited by 65 · see citing works
Zamani, Y., Amoabediny, G., Mohammadi, J., et al. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103638 · Cited by 65 · see citing works
Dorati, R., Pisani, S., Maffeis, G., Conti, B., Modena, T., Chiesa, E., Bruni, G., Musazzi, U. M., & Genta, I. (2018) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2018.06.050 · Cited by 64 · see citing works
Mohseni, M., Hutmacher, D. W., & Castro, N. J. (2018) · Polymers · doi:10.3390/polym10010040 · Cited by 60 · see citing works
Pitjamit, S., Thunsiri, K., Nakkiew, W., et al. (2020) · Materials · doi:10.3390/ma13071564 · Cited by 59 · see citing works
“Thus, copolymers or blended composite materials are required to improve the properties of the fabricated materials [13].”
BackgroundFernández-Cervantes, I., Morales, M. A., Agustín-Serrano, R., et al. (2019) · Journal of Materials Science · doi:10.1007/s10853-019-03537-1 · Cited by 57 · see citing works
Ma, J., Lin, L., Zuo, Y., Zou, Q., Ren, X., Li, J., & Li, Y. (2019) · RSC Advances · doi:10.1039/c8ra06652c · Cited by 56 · see citing works
Mechanical performance of 3D printed polylactide during degradation
Moetazedian, A., Gleadall, A., Han, X., Ekinci, A., Mele, E., & Silberschmidt, V. V. (2020) · Additive manufacturing · doi:10.1016/j.addma.2020.101764 · Cited by 55 · see citing works
A novel waterborne polyurethane with biodegradability and high flexibility for 3D printing
Feng, Z., Wang, D., Zheng, Y., Zhao, L., Xu, T., Guo, Z., Hussain, M. I., Zeng, J., Lou, L., Sun, Y., et al. (2020) · Biofabrication · doi:10.1088/1758-5090/ab7de0 · Cited by 56 · see citing works
Arslan, A., Steiger, W., Roose, P., den Bergen, H. V., Gruber, P., Zerobin, E., Chalupa‐Gantner, F., Guillaume, O., Ovsianikov, A., Vlierberghe, S. V., et al. (2020) · Materials Today · doi:10.1016/j.mattod.2020.10.005 · Cited by 54 · see citing works
Electrohydrodynamic jet 3D printing of PCL/PVP composite scaffold for cell culture
Li, K., Wang, D., Zhao, K., Song, K., & Liang, J. (2020) · Talanta · doi:10.1016/j.talanta.2020.120750 · Cited by 51 · see citing works
Bruyas, A., Moeinzadeh, S., Kim, S., Lowenberg, D. W., & Yang, Y. (2018) · Tissue Engineering Part A · doi:10.1089/ten.tea.2018.0130 · Cited by 50 · see citing works
“It has been shown elsewhere that the stiffness of PCL-based scaffolds is correlated with the remaining mass of scaffolds during the degradation.(36,38) The effect of E-beam sterilization on the degradation kinetics of scaffolds in vivo remains to be evaluated in the future.”
BackgroundRicci, D., Nava, M. M., Zandrini, T., Cerullo, G., Raimondi, M. T., & Osellame, R. (2017) · Materials · doi:10.3390/ma10010066 · Cited by 49 · see citing works
Zamani, Y., Mohammadi, J., Amoabediny, G., Visscher, D. O., Helder, M. N., Zandieh‐Doulabi, B., & Klein‐Nulend, J. (2018) · Biomedical Materials · doi:10.1088/1748-605x/aaeb82 · Cited by 45 · see citing works
Wang, D., Jin, K.-Y., Zhao, P., Lin, Q. D., Kang, K., & Hai, J. (2021) · International Journal of Nanomedicine · doi:10.2147/ijn.s307335 · Cited by 35 · see citing works
Composite fibrous membrane comprising PLA and PCL fibers for biomedical application
Zhang, S., Yan, D., Zhao, L., & Lin, J. (2022) · Composites Communications · doi:10.1016/j.coco.2022.101268 · Cited by 42 · see citing works
Farmer, Z.-L., Domínguez‐Robles, J., Mancinelli, C., Larrañeta, E., & Lamprou, D. A. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119512 · Cited by 44 · see citing works
Thunsiri, K., Pitjamit, S., Pothacharoen, P., et al. (2020) · Materials · doi:10.3390/ma13153417 · Cited by 41 · see citing works
3D printing and bioprinting using multiphoton lithography
Zuev, D. M., Nguyen, A. K., Putlyaev, V. I., & Narayan, R. J. (2020) · Bioprinting · doi:10.1016/j.bprint.2020.e00090 · Cited by 39 · see citing works
3D PCL/Gelatin/Genipin Nanofiber Sponge as Scaffold for Regenerative Medicine
Merk, M. W., Chirikian, O., & Adlhart, C. (2021) · Materials · doi:10.3390/ma14082006 · Cited by 35 · see citing works
“These findings may be explained by the slow degradation rate of PCL, which was reported to be 2–4 years for complete resorption in vivo [75], or the lack of enzymes present in the experimental condition, which would facilitate the hydrolytic cleavage of the ester bonds [68].”
BackgroundBarata, D. B., Provaggi, E., van Blitterswijk, C., & Habibović, P. (2017) · Lab on a Chip · doi:10.1039/c7lc00802c · Cited by 35 · see citing works
Meng, Z., He, J., Li, J., Su, Y., & Li, D. (2020) · Virtual and Physical Prototyping · doi:10.1080/17452759.2020.1808937 · Cited by 35 · see citing works
A comparative study on in vitro degradation behavior of PLLA-based copolymer monofilaments
Shi, D., Kang, Y., Zhang, G., Gao, C., Lu, W. J., Yang, C., Zou, H. H., & Jiang, H. (2018) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2018.11.005 · Cited by 35 · see citing works
Rajaram, K., Lee, J. H., Youn, J. K., Jang, T., Han, W. B., Yang, S. M., Shin, J., Ko, G., Kim, D., Han, S., et al. (2023) · Advanced Materials · doi:10.1002/adma.202307391 · Cited by 37 · see citing works
Hympanova, L. H., da Cunha, M. G. M. C. M., Rynkevic, R., Zündel, M., Gallego, M. R., Vange, J., Callewaert, G., Urbánková, I., der Aa, F. V., Mazza, E., et al. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.06.032 · Cited by 32 · see citing works
Zabidi, A. Z., Li, S., Felfel, R. M., et al. (2018) · Additive manufacturing · doi:10.1016/j.addma.2018.11.021 · Cited by 30 · see citing works
Self-citationSupercritical processing of PCL and PCL-PEG blends to produce improved PCL-based porous scaffolds
Guastaferro, M., Baldino, L., Cardea, S., & Reverchon, E. (2022) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2022.105611 · Cited by 30 · see citing works
Shin, D. Y., Kang, M., Kang, I., et al. (2018) · Journal of Biomaterials Applications · doi:10.1177/0885328218763660 · Cited by 28 · see citing works
Poocza, L., Gottschaldt, M., Markweg, E., Hauptmann, N., Hildebrand, G., Pretzel, D., Hartlieb, M., Reichardt, C. L., Kübel, J., Schubert, U. S., et al. (2017) · Advanced Engineering Materials · doi:10.1002/adem.201600686 · Cited by 25 · see citing works
Self-citationBinary polymer systems for biomedical applications
Afshar, A., Gültekinoğlu, M., & Edirisinghe, M. J. (2022) · International Materials Reviews · doi:10.1080/09506608.2022.2069451 · Cited by 28 · see citing works
“[586,587] and PVP [588,589] to build substitute tissues for human bodies.”
Hauptmann, N., Lian, Q., Ludolph, J., Rothe, H., Hildebrand, G., & Liefeith, K. (2019) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2018.0284 · Cited by 23 · see citing works
“Basic outlines of the preparation of LCM copolymers with defined biomechanical and biodegradation properties were already published.(69) Under all LCM variants two compositions were chosen; one as favored material for bone TE and the second composition for simulation of the tumor extracellular environment.”
MethodSelf-citationFelfel, R. M., Gupta, D., Zabidi, A. Z., Prosser, A., Scotchford, C. A., Sottile, V., & Grant, D. M. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.09.035 · Cited by 24 · see citing works
“This was ascribed to the slower degradation rate and lowmechanical properties of PCL alone in comparison to poly(D,L-lactide) [12].”
BackgroundMethodInfluentialSelf-citationNazemzadeh, N., Soufivand, A. A., & Abolfathi, N. (2021) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-021-08124-w · Cited by 23 · see citing works
Cell-instructive high-resolution micropatterned polylactic acid surfaces
Barata, D. B., Dias, P., Wieringa, P. A., van Blitterswijk, C., & Habibović, P. (2017) · Biofabrication · doi:10.1088/1758-5090/aa7d24 · Cited by 22 · see citing works
Mohammed, A., Saeed, A., ElShaer, A., et al. (2023) · Pharmaceuticals · doi:10.3390/ph16040627 · Cited by 19 · see citing works
“5 mm and can incorporate a wide range of biocompatible and biodegradable polymeric materials suitable for tissue engineering [9,10].”
BackgroundPorous 3D Scaffolds Enhance MSC Vitality and Reduce Osteoclast Activity
Spreda, M., Hauptmann, N., Lehner, V., Biehl, C., Liefeith, K., & Lips, K. S. (2021) · Molecules · doi:10.3390/molecules26206258 · Cited by 19 · see citing works
“At the temperature of 37 ◦C, 20% of the scaffold is degraded after 90 days of incubation [17].”
BackgroundMethodInfluentialSelf-citationPhotoresins based on acrylated epoxidized soybean oil and benzenedithiols for optical 3D printing
Miezinyte, G., Ostrauskaitė, J., Rainosalo, E., et al. (2018) · Rapid Prototyping Journal · doi:10.1108/rpj-04-2018-0101 · Cited by 19 · see citing works
Preparation of Polylactic Acid/Calcium Peroxide Composite Filaments for Fused Deposition Modelling
Mohammed, A., Kovačev, N., ElShaer, A., et al. (2023) · Polymers · doi:10.3390/polym15092229 · Cited by 18 · see citing works
Teamsinsungvon, A., Ruksakulpiwat, Y., & Ruksakulpiwat, Y. (2022) · Polymers · doi:10.3390/polym14163310 · Cited by 20 · see citing works
Fabrication, Flow Assembly, and Permeation of Microscopic Any‐Shape Particles
Lüken, A., Stüwe, L., Rauer, S. B., et al. (2022) · Small · doi:10.1002/smll.202107508 · Cited by 18 · see citing works
Kampleitner, C., Changi, K., Felfel, R. M., et al. (2020) · Biomaterials Science · doi:10.1039/c9bm01827a · Cited by 17 · see citing works
Self-citationSharma, D., Arora, S., & Singh, J. (2019) · International Journal of Polymeric Materials · doi:10.1080/00914037.2019.1655750 · Cited by 17 · see citing works
Fabrication of Admicelled Natural Rubber by Polycaprolactone for Toughening Poly(lactic acid)
Phromma, W., & Magaraphan, R. (2017) · Journal of Polymers and the Environment · doi:10.1007/s10924-017-1121-3 · Cited by 15 · see citing works
Butt, M. S., Afsheen, R., Saeed, H., et al. (2024) · Results in Engineering · doi:10.1016/j.rineng.2024.103714 · Cited by 14 · see citing works
Xu, M., Guo, C., Dou, H., Zuo, Y., Sun, Y., Zhang, J., & Li, W. (2019) · Polymer Chemistry · doi:10.1039/c9py00174c · Cited by 14 · see citing works
Aliha, M. R. M., Nazemzadeh, N., Ghoreishi, S. M. N., & Rajabi-Kafshgar, A. (2023) · Theoretical and Applied Fracture Mechanics · doi:10.1016/j.tafmec.2023.103953 · Cited by 15 · see citing works
Förster, Y., Schulze, S., Penk, A., Neuber, C., Möller, S., Hintze, V., Scharnweber, D., Schnabelrauch, M., Pietzsch, J., Huster, D., et al. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.111157 · Cited by 13 · see citing works
MSC differentiation on two-photon polymerized, stiffness and BMP2 modified biological copolymers
Böhrnsen, F., Krier, M., Grohmann, S., Hauptmann, N., Frant, M., Klaus, L., & Schliephake, H. (2019) · Biomedical Materials · doi:10.1088/1748-605x/ab0362 · Cited by 12 · see citing works
3D Printing of Bone Substitutes Based on Vat Photopolymerization Processes: A Systematic Review
Enbergs, S., Spinnen, J., Dehne, T., & Sittinger, M. (2023) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1155/2023/3901448 · Cited by 11 · see citing works
Wang, B., Xu, H., Li, J., Cheng, D., Lu, Y., & Liu, L. (2021) · RSC Advances · doi:10.1039/d1ra04436b · Cited by 12 · see citing works
Zamani, Y., Mohammadi, J., Amoabediny, G., et al. (2020) · Regenerative Engineering and Translational Medicine · doi:10.1007/s40883-020-00163-1 · Cited by 11 · see citing works
Galocha-León, C., Antich, C., Clares, B., Voltes-Martínez, A., Marchal, J. A., & Gálvez‐Martín, P. (2024) · Pharmaceutics · doi:10.3390/pharmaceutics16111422 · Cited by 11 · see citing works
Additive Manufacturing of Bio-Inspired Microstructures for Bone Tissue Engineering
Top, N., Gökçe, H., & Şahin, İ. (2023) · Experimental Techniques · doi:10.1007/s40799-023-00630-8 · Cited by 10 · see citing works
Poly(ester‐co‐glycidyl methacrylate) for digital light processing in biomedical applications
Risangud, N., Jiraborvornpongsa, N., Pasee, S., et al. (2021) · Journal of Applied Polymer Science · doi:10.1002/app.51391 · Cited by 10 · see citing works
MacCraith, E., Joyce, M., do Amaral, R. J. F. C., O’Brien, F. J., & Davis, N. F. (2022) · International Urogynecology Journal · doi:10.1007/s00192-022-05160-2 · Cited by 9 · see citing works
“Polycaprolactone (PCL) appears promising for SUI surgery because of its elasticity, miscibility with other polymers, flexibility and customisable degradation properties [12].”
BackgroundZamani, Y., Amoabediny, G., Mohammadi, J., et al. (2021) · Iranian Biomedical Journal · doi:10.29252/ibj.25.2.78 · Cited by 9 · see citing works
“However, poly(α-hydroxy esters) lack osteoconductivity and cell recognition sites [2,4] .”
Zhao, Z., Feng, X., Zhao, Y., et al. (2025) · International Journal of Nanomedicine · doi:10.2147/ijn.s495204 · Cited by 8 · see citing works
“48,49 Considering the typical 3–4 week healing time for mouse skulls, we selected 50:50 PLGA for our initial studies.”
3D printing of TPMS microlattice: indentation characterisation and numerical analysis
Harley, W. S., Vidler, C., Tee, Y. L., et al. (2024) · Virtual and Physical Prototyping · doi:10.1080/17452759.2024.2432412 · Cited by 8 · see citing works
Firoozabadi, F. D., A., A. R. S., & Asefnejad, A. (2023) · Polymer-Plastics Technology and Materials · doi:10.1080/25740881.2023.2276775 · Cited by 8 · see citing works
“66–68] 3.13.1.”
InfluentialA Comparative Study of Three Approaches to Fibre’s Surface Functionalization
Dulnik, J., Jeznach, O., & Sajkiewicz, P. (2022) · Journal of Functional Biomaterials · doi:10.3390/jfb13040272 · Cited by 8 · see citing works
“, copolymerization [8], controlled crystallization [9], or the use of additives [10].”
BackgroundTwo-Photon Polymerization in Optics, Microfluidics, and Biomedicine
El-Tamer, A., Hinze, U., & Chichkov, B. N. (2021) · doi:10.1007/978-3-030-63647-0_35 · Cited by 8 · see citing works
Wei, P., Wang, Y., Xia, Y., He, Y. W., & Wang, Y. (2016) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-016-5975-8 · Cited by 9 · see citing works
“These polymers possess good biodegradability and faster degradation rate under natural conditions, especially in the presence of enzyme and microorganism, making them could be used as packing and tissue repair materials [6, 7].”
BackgroundHauptmann, N., Ludolph, J., Rothe, H., et al. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23063115 · Cited by 7 · see citing works
Self-citationMultiphoton Polymerization-Based Micro/Nanomanufacturing Toward Precision Medicine
Hu, J., Ren, A., Lv, W., Aazmi, A., Qin, C., Liang, X., Xu, X., Yu, M., Li, Q., Yang, H., et al. (2024) · Engineering · doi:10.1016/j.eng.2024.10.016 · Cited by 6 · see citing works
Alshneeqat, M. G., Abualbandora, T. A., & Mourad, A. I. (2025) · Progress in Additive Manufacturing · doi:10.1007/s40964-025-01126-0 · Cited by 5 · see citing works
Carvalho, J. A., Jayme, C. C., Matsuo, F. S., & Tedesco, A. C. (2023) · Journal of Applied Polymer Science · doi:10.1002/app.54978 · Cited by 5 · see citing works
Mohammed, A. H., Tirnoveanu, A., Webb, W. R., Melaibari, A., Memić, A., Aslam, M., Elshaer, A., Hassanin, H., & Essa, K. (2025) · Journal of Manufacturing and Materials Processing · doi:10.3390/jmmp9050149 · Cited by 4 · see citing works
“Moreover, FDM achieves a printing accuracy of up to +/ − 0.5 mm and can utilize a wide range of biocompatible and biodegradable polymeric materials suitable for tissue engineering [11,12].”
InfluentialNanoscale Biodegradable Printing for Designed Tuneability of Vaccine Delivery Kinetics
Peeler, D. J., Sun, R., Kütahya, C., et al. (2025) · Advanced Materials · doi:10.1002/adma.202417290 · Cited by 4 · see citing works
Biomechanical analysis of an absorbable material for treating fractures of the inferior orbital wall
Yu, J., Zhang, H., Xu, Q., et al. (2024) · International Journal of Ophthalmology · doi:10.18240/ijo.2024.07.19 · Cited by 4 · see citing works
“…absorbable materials during the degradation An absorbable material for orbital fracture process are elucidated based on relevant research reports [8-9] , In this study, the 10-fold gradient decay of the Young’s modulus of the material was simulated after shaping the absorbable plate, considering…”
MethodWunderer, M. S., Sparenberg, V., Biehl, C., et al. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26125837 · Cited by 2 · see citing works
“This could be due to the slow degradation of LCM described by Felfel et al., 2016 [23], who showed only 10–30% of dry mass loss after 80 days of incubation in PBS at 37 ◦ C.”
InfluentialSelf-citationEbrahimi, H. P., Sharif, F., & A., A. R. S. (2021) · Polymer Composites · doi:10.1002/pc.26087 · Cited by 2 · see citing works
Carvalho, J. A., Jayme, C. C., & Tedesco, A. C. (2025) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.35675 · Cited by 1 · see citing works
Pérez-Sánchez, L., Carbajal-Casique, M. N., Chimal, R. Á., et al. (2025) · ACS Omega · doi:10.1021/acsomega.5c06247 · Cited by 1 · see citing works
3D-printable composites for magnetic refrigeration based on Ni-Mn-In-Co shape memory alloys
Khanna, D. L. R. (2023) · doi:10.48035/tesis/2454/46629 · Cited by 1 · see citing works
Nazemzadeh, N., Soufivand, A. A., & Abolfathi, N. (2021) · Research Square · doi:10.21203/rs.3.rs-218617/v1 · Cited by 1 · see citing works
Tissue Engineering and Cell Technologies in the Treatment of Urethral Strictures
Rassomakhina, N. V., Likhov, A. R., Shisterova, D. R., Apukhtina, U. A., Volodina, V. N., Грицков, И. О., Kasyan, G. R., & Zherdeva, V. V. (2026) · Biochemistry (Moscow) · doi:10.1134/s0006297925604113 · Cited by 1 · see citing works
“Even the most advanced fabrication techniques, such as 3D bioprinting or electrospinning, face limitations in resolution, scalability, or mechanical compatibility [49, 86-90].”
Varan, C., Aksüt, D., Şen, M., et al. (2026) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2026.107456
Ahrabi, T., Shojaei, A., Khasraghi, S. S., & Matin, M. M. (2025) · Results in Engineering · doi:10.1016/j.rineng.2025.108658
“Nanoscale biodegradable printing for designed tuneability of vaccine delivery kinetics”Preprint
Peeler, D. J., Sun, R., Kütahya, C., et al. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.10.02.616252
Research status and development trend of 3D printing binders
Song, Y., Liang, Y., Li, X., et al. (2023) · Matériaux & Techniques · doi:10.1051/mattech/2023009
- Authors
- Felfel, R. M., Poocza, L., Gimeno-Fabra, M., Milde, T., Hildebrand, G., Ahmed, I., Scotchford, C., Sottile, V., Grant, D. M., & Liefeith, K.
- Affiliations
- University of Nottingham (GB)
- Institute for Bioprocessing and Analytical Measurement Techniques (DE)
- Corresponding author
- Grant, David M
- Liefeith, Klaus
- ORCID
- Venue
- Biomedical Materials
- Publisher
- IOP Publishing
- Published
- 2016-02-01
- Volume
- 11
- Issue
- 1
- Pages
- 015011
- ISSN
- 1748-6041 (ISSN-L)
- 1748-605X
- OpenAlex
- W2272323856
- Cited by
- 103
- References
- 74
- Citations by year
- 2026: 2 · 2025: 8 · 2024: 5 · 2023: 12 · 2022: 10 · 2021: 12 · 2020: 16 · 2019: 11 · 2018: 11 · 2017: 11 · 2016: 3
- FWCI
- 5.13
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Biomedical Materials (publishedVersion)
- PubMed (publishedVersion)
- Nottingham ePrints (University of Nottingham) (submittedVersion, cc-by)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- Funders
- European Union’s Seventh Framework Programme (263363)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Engineering › Biomedical Engineering › Nonlinear Optical Materials Studies
- Keywords
- two-photon polymerization, 3D scaffolds, in vitro degradation, mechanical properties, compressive strength, mass loss, glass transition temperature, activation energy of degradation
- MeSH terms
- Equipment Design, Light, Materials Testing, Polyesters, Polymers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-11.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-11.
Cited sources are checked by gpt-6-sol.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review