The DOI matches its Crossref record.
Osteoinduction in porous hydroxyapatite implanted in heterotopic sites of different animal models
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laurencin, C., Khan, Y., & El-Amin, S. F. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.1.49 · Cited by 716
Osteoinduction of bone grafting materials for bone repair and regeneration
García-Gareta, E., Coathup, M. J., & Blunn, G. W. (2015) · Bone · doi:10.1016/j.bone.2015.07.007 · Cited by 649
3D microenvironment as essential element for osteoinduction by biomaterials
Habibovic, P., Yuan, H., van der Valk, C. M., Meijer, G., van Blitterswijk, C. A., & de Groot, K. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.056 · Cited by 615
Tissue Engineering of Bone: Material and Matrix Considerations
Khan, Y., Yaszemski, M. J., Mikos, A. G., & Laurencin, C. T. (2008) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.g.01260 · Cited by 481
G, R., S, B., Venkatesan, B., & Vellaichamy, E. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.12.133 · Cited by 56
Metadata
- Authors
- Ripamonti, U.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1996-01
- Volume
- 17
- Issue
- 1
- Pages
- 31-35
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1981393311
- Cited by
- 499
- References
- 0
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Osteoinduction in porous hydroxyapatite implanted in heterotopic sites of different animal models. https://app.cochat.ai/papers/10.1016/0142-9612(96)80752-6
- The paper
- Ripamonti, U. (1996). Osteoinduction in porous hydroxyapatite implanted in heterotopic sites of different animal models. Biomaterials. https://doi.org/10.1016/0142-9612(96)80752-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.