The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Process analysis, monitoring and diagnosis, using multivariate projection methods
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wold, S., Esbensen, K., & Geladi, P. (1987) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(87)80084-9 · Cited by 11,606
Goodall, C. (1988) · Technometrics · doi:10.1080/00401706.1988.10488412 · Cited by 8,675
Partial least-squares regression: a tutorial
Geladi, P., & Kowalski, B. R. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80028-9 · Cited by 6,992
A User's Guide to Principal Components
Leigh, S., & Jackson, J. E. (1993) · Technometrics · doi:10.2307/1269292 · Cited by 3,332
Economic Control of Quality of Manufactured Product.
Hotelling, H., & Shewhart, W. A. (1932) · Journal of the American Statistical Association · doi:10.2307/2277676 · Cited by 3,070
Cross-Validatory Estimation of the Number of Components in Factor and Principal Components Models
Wold, S. (1978) · Technometrics · doi:10.1080/00401706.1978.10489693 · Cited by 2,601
Höskuldsson, A. (1988) · Journal of Chemometrics · doi:10.1002/cem.1180020306 · Cited by 1,881
Multivariate SPC Charts for Monitoring Batch Processes
Nomikos, P., & MacGregor, J. F. (1995) · Technometrics · doi:10.1080/00401706.1995.10485888 · Cited by 1,422
Soft modelling: The Basic Design and Some Extensions
Wold, H. (1982) · Medical Entomology and Zoology · Cited by 1,314
The Exponentially Weighted Moving Average
Hunter, J. S. (1986) · Journal of Quality Technology · doi:10.1080/00224065.1986.11979014 · Cited by 1,136
Cited by
De Maesschalck, R., Jouan-Rimbaud, D., & Massart, D. L. (2000) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(99)00047-7 · Cited by 2,325
The process chemometrics approach to process monitoring and fault detection
Wise, B. M., & Gallagher, N. B. (1996) · Journal of Process Control · doi:10.1016/0959-1524(96)00009-1 · Cited by 852
Generalized contribution plots in multivariate statistical process monitoring
Westerhuis, J. A., Gurden, S. P., & Smilde, A. K. (2000) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(00)00062-9 · Cited by 507
(2013) · CRC Press eBooks · doi:10.1201/b15314 · Cited by 435
Process data analytics in the era of big data
Qin, S. J. (2014) · AIChE Journal · doi:10.1002/aic.14523 · Cited by 383
Metadata
- Authors
- Kourti, T.
- Venue
- Chemometrics and Intelligent Laboratory Systems
- Publisher
- Elsevier BV
- Published
- 1995-04
- Volume
- 28
- Issue
- 1
- Pages
- 3-21
- ISSN
- 0169-7439 (ISSN-L)
- OpenAlex
- W2079441011
- Cited by
- 780
- References
- 26
- FWCI
- 22.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Process analysis, monitoring and diagnosis, using multivariate projection methods. https://app.cochat.ai/papers/10.1016/0169-7439(94)00079-x
- The paper
- Kourti, T. (1995). Process analysis, monitoring and diagnosis, using multivariate projection methods. Chemometrics and Intelligent Laboratory Systems. https://doi.org/10.1016/0169-7439(94)00079-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.