Lung damage from exposure to pulsed ultrasound
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Motivated by a recent finding that threshold pressures for hemorrhage in mouse lung exposed to the fields of an electrohydraulic lithotripter were less than 2 MPa, we extended the exposures to pulsed ultrasound. Sharply defined thresholds of the order of 1 MPa were found with 10 microseconds length pulses and roughly twice that value for 1 microsecond pulses. The thresholds at 4 MHz are greater than at 1 MHz. The thresholds are comparable for focused and unfocused fields. As would be expected for a cavitation-like phenomenon, temporal average intensity is a very poor predictor of this effect. In the extreme case, lesions were found at temporal average intensities on the order of 1 mW/cm2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound
Apfel, R. E., & Holland, C. K. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90125-g · Cited by 690
Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment
Holland, C. K., & Apfel, R. E. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.400102 · Cited by 310
Threshold Ultrasonic Dosages for Structural Changes in the Mammalian Brain
Fry, F. J., Kossoff, G., Eggleton, R. C., & Dunn, F. (1970) · The Journal of the Acoustical Society of America · doi:10.1121/1.1912301 · Cited by 241
Generation of transient cavities in liquids by microsecond pulses of ultrasound
Flynn, H. G. (1982) · The Journal of the Acoustical Society of America · doi:10.1121/1.388622 · Cited by 212
Cited by
Ultrasound–biophysics mechanisms
O’Brien, W. D. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.010 · Cited by 745
Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound
Apfel, R. E., & Holland, C. K. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90125-g · Cited by 690
Mechanical Bioeffects of Ultrasound
Dalecki, D. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140126 · Cited by 564
Intramembrane cavitation as a unifying mechanism for ultrasound-induced bioeffects
Krasovitski, B., Frenkel, V., Shoham, S., & Kimmel, E. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1015771108 · Cited by 550
International recommendations and guidelines for the safe use of diagnostic ultrasound in medicine
Barnett, S. B., Ter Haar, G. R., Ziskin, M. C., Rott, H.-D., Duck, F. A., & Maeda, K. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00204-0 · Cited by 403
Metadata
- Authors
- Child, S. Z., Hartman, C. L., Schery, L. A., & Carstensen, E. L.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 1990
- Volume
- 16
- Issue
- 8
- Pages
- 817-825
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W1986431498
- Cited by
- 214
- References
- 4
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.