The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment
Abstract
Transient cavitation is a discrete phenomenon that relies on the existence of stabilized nuclei, or pockets of gas within a host fluid, for its genesis. A convenient descriptor for assessing the likelihood of transient cavitation is the threshold pressure, or the minimum acoustic pressure necessary to initiate bubble growth and subsequent collapse. An automated experimental apparatus has been developed to determine thresholds for cavitation produced in a fluid by short tone bursts of ultrasound at 0.76, 0.99, and 2.30 MHz. A fluid jet was used to convect potential cavitation nuclei through the focal region of the insonifying transducer. Potential nuclei tested include 1-μm polystyrene spheres, microbubbles in the 1- to 10-μm range that are stabilized with human serum albumin, and whole blood constituents. Cavitation was detected by a passive acoustical technique that is sensitive to sound scattered from cavitation bubbles. Measurements of the transient cavitation threshold in water, in a fluid of higher viscosity, and in diluted whole blood are presented. These experimental measurements of cavitation thresholds elucidate the importance of ultrasound, host fluid, and nuclei parameters in determining these thresholds. These results are interpreted in the context of an approximate analytical theory for the prediction of the onset of cavitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Suslick, K. S., Hammerton, D. A., & Cline, R. E. (1986) · Journal of the American Chemical Society · doi:10.1021/ja00278a055 · Cited by 1,243
Cited by
Free radical formation induced by ultrasound and its biological implications
Riesz, P., & Kondo, T. (1992) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(92)90021-8 · Cited by 656
Coussios, >. C., Farny, C. H., Ter Haar, G., & Roy, R. A. (2007) · International Journal of Hyperthermia · doi:10.1080/02656730701194131 · Cited by 469
Micelles and nanoparticles for ultrasonic drug and gene delivery
Husseini, G. A., & Pitt, W. G. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.008 · Cited by 468
Sonogenetics is a non-invasive approach to activating neurons in Caenorhabditis elegans
Ibsen, S., Tong, A., Schutt, C., Esener, S., & Chalasani, S. H. (2015) · Nature Communications · doi:10.1038/ncomms9264 · Cited by 375
Ultrasound modulates ion channel currents
Kubanek, J., Shi, J., Marsh, J., Chen, D., Deng, C., & Cui, J. (2016) · Scientific Reports · doi:10.1038/srep24170 · Cited by 353
Metadata
- Authors
- Holland, C. K., & Apfel, R. E.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1990-11-01
- Volume
- 88
- Issue
- 5
- Pages
- 2059-2069
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2005751180
- Cited by
- 310
- References
- 1
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment. https://app.cochat.ai/papers/10.1121/1.400102
- The paper
- Holland, C. K., & Apfel, R. E. (1990). Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.400102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.