Conditions for the equivalence of continuous to pulsed low dose rate brachytherapy

Open access
Brenner, D.J, Hall, E.J·1991·International Journal of Radiation Oncology*Biology*Physics

Abstract

Low dose rate interstitial brachytherapy is extremely useful for those tumors that are accessible for an implant, while the introduction of remote afterloaders has eliminated exposure to nursing personnel. Currently, such machines require an inventory of many sources which are loaded into catheters implanted in the tumor and kept in place during treatment. A significant simplification of such machines would be possible in a pulsed mode, with a single source moving under computer control through the catheters. Assuming that the treatment time and average dose rate are kept unchanged, the question addressed is to find those combinations of radiation pulse widths and frequencies that would be functionally equivalent to a continuous irradiation. The linear-quadratic formalism was used to reanalyze published low dose-rate studies on cells of human origin to obtain 36 parameter sets [alpha, beta, T1/2], where T1/2 is the half time for sublethal damage repair. These data are consistent with those for human tumors. For each parameter set, those combinations of pulse width and frequency were calculated that would yield a functionally equivalent cell survival. For a regimen of 30 Gy in 60 hr, a pulse width of 10 min with a period between pulses of 1 hr would be appropriate for all the cell lines considered. Similar results were found for other possible time/dose combinations. For late effects, a 1-hr period between 10-min pulses might produce up to a 2% increase in late-effect probability, which is probably acceptable for the small volumes irradiated in interstitial brachytherapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0360-3016(91)90158-z

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 300

Metadata

Authors
Brenner, D. J., & Hall, E. J.
Venue
International Journal of Radiation Oncology*Biology*Physics
Publisher
Elsevier BV
Published
1991-01
Volume
20
Issue
1
Pages
181-190
ISSN
0360-3016 (ISSN-L)
OpenAlex
W2078869193
Cited by
300
References
14
FWCI
12.90
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Conditions for the equivalence of continuous to pulsed low dose rate brachytherapy. https://app.cochat.ai/papers/10.1016/0360-3016(91)90158-z
The paper
Brenner, D. J., & Hall, E. J. (1991). Conditions for the equivalence of continuous to pulsed low dose rate brachytherapy. International Journal of Radiation Oncology*Biology*Physics. https://doi.org/10.1016/0360-3016(91)90158-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.