Multichannel electrical stimulation of the auditory nerve in man. I. Basic psychophysics
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transformed Up-Down Methods in Psychoacoustics
Levitt, H. (1971) · The Journal of the Acoustical Society of America · doi:10.1121/1.1912375 · Cited by 5,477
Electrical Stimulation of the Auditory Nerve in Man
SIMMONS, F. B. (1966) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1966.00760030004003 · Cited by 613
Stevens, S. S. (1955) · The Journal of the Acoustical Society of America · doi:10.1121/1.1908048 · Cited by 467
Physiological Considerations in Artificial Stimulation of the Inner Ear
Kiang, N. Y. S., & Moxon, E. C. (1972) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348947208100513 · Cited by 342
Auditory Prostheses Research with Multiple Channel Intracochlear Stimulation in Man
Eddington, D. K., Dobelle, W. H., Mladejovsky, M. G., Brackmann, D. E., & Parkin, J. L. (1978) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894780870s602 · Cited by 334
Temporal Summation of Loudness: An Analysis
Zwislocki, J. J. (1969) · The Journal of the Acoustical Society of America · doi:10.1121/1.1911708 · Cited by 264
Multichannel electrical stimulation of the auditory nerve in man. II. Channel interaction
Shannon, R. V. (1983) · Hearing Research · doi:10.1016/0378-5955(83)90115-6 · Cited by 203
Self-citationBurns, E. M., & Viemeister, N. F. (1976) · The Journal of the Acoustical Society of America · doi:10.1121/1.381166 · Cited by 153
SPEECH RECOGNITION IN DEAF SUBJECTS WITH MULTICHANNEL INTRACOCHLEAR ELECTRODESa
Eddington, D. K. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31637.x · Cited by 146
Research Plan for Evaluating Subjects Presently Fitted with Implanted Auditory Prostheses
Bilger, R. C., Black, F. O., & Hopkinson, N. T. (1977) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894770860s303 · Cited by 142
Tong, Y. C., Blamey, P. J., Dowell, R. C., & Clark, G. M. (1983) · The Journal of the Acoustical Society of America · doi:10.1121/1.389620 · Cited by 137
Neural Encoding of Sound Sensation Evoked by Electrical Stimulation of the Acoustic Nerve
Merzenich, M. M., Michelson, R. P., Pettit, C. R., Schindler, R. A., & Reid, M. (1973) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348947308200407 · Cited by 125
Characteristics of the Metal-Tissue Interface of Stimulation Electrodes
Dymond, A. M. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324585 · Cited by 121
Neural and mechanical responses to electric stimulation of the cat's inner ear.
Moxon, E. C. (1971) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 116
Psychophysical studies for two multiple-channel cochlear implant patients
Tong, Y. C., Clark, G. M., Blamey, P. J., Busby, P. A., & Dowell, R. C. (1982) · The Journal of the Acoustical Society of America · doi:10.1121/1.387342 · Cited by 109
A preliminary report on a multiple-channel cochlear implant operation
Tong, Y. C., Black, R. C., Clark, G. M., Forster, I. C., Millar, J. B., O'Loughlin, B. J., & Patrick, J. F. (1979) · The Journal of Laryngology & Otology · doi:10.1017/s0022215100087545 · Cited by 87
Design and fabrication of an experimental cochlear prosthesis
Loeb, G. E., Byers, C. L., Rebscher, S. J., Casey, D., Fong, M., Schindler, R. A., Gray, R. F., & Merzenich, M. M. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478489 · Cited by 86
Fundamental Considerations in Designing Auditory Implants
Kiang, N. Y. S., Eddington, D. K., & Delgutte, B. (1979) · Acta Oto-Laryngologica · doi:10.3109/00016487909126408 · Cited by 61
Cochlear prostheses in use: Recent speech comprehension results
Hochmair-Desoyer, I. J., Hochmair, E. S., Fischer, R. E., & Burian, K. (1980) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/bf00454232 · Cited by 49
An Eight Channel Scala Tympani Electrode for Auditory Prostheses
Hochmair-Desoyer, I. J., & Hochmair, E. S. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326691 · Cited by 46
Psychophysical and speech perception studies on two multiple channel cochlear implant patients
Tong, Y. C., Millar, J. B., Clark, G. M., Martin, L. F. A., Busby, P. A., & Patrick, J. F. (1980) · The Journal of Laryngology & Otology · doi:10.1017/s002221510009006x · Cited by 33
Bm, C., & Spelman, F. A. (1982) · PubMed · Cited by 17
PERCEPTS FROM SCALA TYMPANI STIMULATION
Tong, Y. C., & Clark, G. M. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31639.x · Cited by 13
Cited by
Speech Recognition with Primarily Temporal Cues
Shannon, R. V., Zeng, F.-G., Kamath, V., Wygonski, J., & Ekelid, M. (1995) · Science · doi:10.1126/science.270.5234.303 · Cited by 3,024
Self-citationBetter speech recognition with cochlear implants
Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991) · Nature · doi:10.1038/352236a0 · Cited by 1,190
Clinical Findings for a Group of Infants and Young Children with Auditory Neuropathy
Rance, G., Beer, D. E., Cone-Wesson, B., Shepherd, R. K., Dowell, R. C., King, A. M., Rickards, F. W., & Clark, G. M. (1999) · Ear and Hearing · doi:10.1097/00003446-199906000-00006 · Cited by 460
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Music Perception with Temporal Cues in Acoustic and Electric Hearing
Kong, Y.-Y., Cruz, R., Jones, J. A., & Zeng, F.-G. (2004) · Ear and Hearing · doi:10.1097/01.aud.0000120365.97792.2f · Cited by 377
Metadata
- Authors
- Shannon, R. V.
- Venue
- Hearing Research
- Publisher
- Elsevier BV
- Published
- 1983-08
- Volume
- 11
- Issue
- 2
- Pages
- 157-189
- ISSN
- 0378-5955 (ISSN-L)
- OpenAlex
- W1989426261
- Cited by
- 364
- References
- 23
- FWCI
- 0.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.